190 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
Product Overview

190 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control is designed for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows. Infrared CO2 sensing, 90 °C sterilization, high humidity cell culture support, and recovery-focused chamber design. The configuration provides RT + 3 to 55 °C, 750 W rated power, a working chamber of 520 × 530 × 690 mm (W × D × H), and external dimensions of 708 × 710 × 1030 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2C-190
Product Family CO2 Incubator, Professional Cell Culture Series
Configuration 190 L
Rated Operating Power 750 W
Working Chamber Size 520 × 530 × 690 mm (W × D × H)
Overall Dimensions 708 × 710 × 1030 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Heating Method Gas-jacket microcomputer PID control
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Sterilization 90 °C high-temperature and high-humidity sterilization
Optional Accessories and Functions HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable
Performance Features
  • Infrared CO2 sensing supports stable CO2 control and faster recovery in frequent door-opening workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • A 90 °C high-temperature and high-humidity sterilization cycle can treat the chamber and internal components. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Microbial filtration at the CO2 inlet and optional HEPA filtration support cleaner chamber conditions. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Door heating reduces condensation on the inner glass door and supports cleaner cell culture operation. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • An LCD display, stackable cabinet design, and data export options support day-to-day laboratory use. This makes real-time parameter review and routine operation easier in cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
  • Alarms cover over-temperature, CO2 deviation, and prolonged door opening according to the product design. This helps operators identify abnormal conditions during unattended or extended cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, contamination-sensitive cultivation, and advanced laboratory incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 708 × 710 × 1030 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: HEPA filtration; humidity display; printer; communication interface; gas regulator; optional O2 control where applicable. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This incubator must be installed in a space that accommodates its external dimensions and provides a stable AC 220 V, 50 Hz power supply. Operation is restricted to ambient temperatures between +5 and +30 °C with chamber components kept accessible for cleaning and inspection.

  • Power Supply Requirement: Connect the incubator only to the specified AC 220 V, 50 Hz power supply.
  • Ambient Temperature Limit: Operate the incubator only within the stated working ambient temperature range of +5 to +30 °C.
  • Chamber Access: Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation.
  • Transport Orientation: Keep the packed unit upright during transport and use suitable lifting equipment to reduce movement and impact risk.
  • Sterilization Cycle: Use the 90 °C high-temperature and high-humidity sterilization cycle to treat the chamber and internal components during maintenance.

Confirm the installation site accommodates the incubator's external dimensions and provides the specified AC 220 V, 50 Hz power supply before unpacking. Keep the packed unit upright during transport and use suitable lifting equipment to move it into position.

Required Equipment: Suitable lifting equipment

  1. Confirm Installation Space
    Confirm that the installation space accommodates the incubator's external dimensions and provides access for cleaning and operation.
  2. Transport Unit Safely
    Keep the packed unit upright during transport and use suitable lifting equipment to move it into position.
  3. Position Incubator
    Position the incubator so that the chamber, sensors, shelves, filters, doors, test ports and control interfaces remain accessible.
  4. Connect Power Supply
    Connect the incubator to the specified AC 220 V, 50 Hz power supply.
  5. Set Control Parameters
    Set the temperature and CO2 control setpoints to the values required for the cell culture workflow.
  6. Verify Recovery Performance
    Verify that CO2 concentration recovers to 5% within no more than 3 minutes after a 30-second door opening.
  7. Monitor Alarms
    Monitor over-temperature, CO2 deviation, and prolonged door-opening alarms during unattended operation.

How quickly does the Atomfair AF-CO2C-190 CO2 incubator recover CO2 concentration after a 30-second door opening?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications. This rapid recovery is supported by the infrared CO2 sensor and gas-jacket PID control system.

What sterilization method does the 190 L Professional Cell Culture Series CO2 incubator use, and how does it affect workflow?

The incubator uses a 90 °C high-temperature and high-humidity sterilization cycle that treats the chamber and internal components. This allows for repeated cleaning and contamination control without requiring chemical agents, supporting dependable maintenance in cell culture workflows.

What are the power supply and ambient temperature requirements for operating the Atomfair AF-CO2C-190 incubator?

The incubator requires AC 220 V, 50 Hz power supply and an ambient working temperature range of +5 to +30 °C. The external dimensions are 708 × 710 × 1030 mm, so adequate space and ventilation must be provided. These infrastructure requirements must be reviewed before installation.

This 190 L CO2 incubator offers infrared CO2 sensing with rapid recovery (≤3 min to 5% CO2 after 30 s door opening) and a 90°C high-temperature sterilization cycle, but requires a 220 V 50 Hz power supply and relies on passive natural evaporation for humidity control, with optional display only.

Positive

  • Infrared CO2 sensing with rapid recovery: Infrared CO2 sensor achieves ±0.1% control accuracy and recovers to 5% CO2 in under 3 minutes after a 30-second door opening, supporting stable conditions in frequent-access workflows.
  • 90°C high-temperature sterilization cycle: A 90°C high-temperature and high-humidity sterilization cycle treats the chamber and internal components, enabling routine decontamination without chemical agents.

Trade-offs

  • Fixed 220V 50Hz power requirement: The incubator is designed for AC 220 V, 50 Hz supply only, limiting direct deployment in regions with 110 V or 60 Hz infrastructure without a step-up transformer or frequency converter.
  • Passive humidity control via natural evaporation: Relative humidity is maintained by natural evaporation, achieving ≥90% RH but without active control or feedback; optional humidity display is available but does not enable regulation.