Color Touchscreen Constant Temperature and Humidity Chamber, 72 L,-10-100℃
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires stable indoor laboratory installation with unobstructed air inlets and service access. Electrical supply must be AC 220 V, 50 Hz with adequate capacity for 2250 W load, and the unit must be kept upright during transport and positioning.
- Installation Environment: Install the chamber in a stable indoor laboratory with service access around all sides for maintenance and cleaning.
- Power Supply: Connect the chamber to a dedicated AC 220 V, 50 Hz power supply capable of delivering 2250 W to avoid electrical overload.
- Transport and Positioning: Keep the chamber upright during unpacking and use suitable lifting equipment to prevent damage to the refrigeration system.
- Ventilation and Access: Ensure air inlets, test ports, drain areas, and controller surfaces remain unobstructed for proper operation and maintenance.
- Alarm Monitoring: Do not disable the independent over-temperature, overload, over-current, compressor overheating, fan overheating, and water-shortage alarms.
Unpack and position the chamber in the designated laboratory space, then connect to the specified power supply. Verify ventilation and access, then set operating parameters and confirm alarm functionality.
Required Equipment: Lifting equipment (e.g., pallet jack or forklift)
- Inspect Chamber
Inspect the chamber for any visible damage after removing the reinforced packaging. - Unpack Chamber
Unpack the chamber while keeping it upright and using suitable lifting equipment to avoid tipping. - Position Chamber
Position the chamber in the designated installation space with clearance for air inlets and service access. - Connect Power
Connect the chamber to the specified AC 220 V, 50 Hz power supply rated for 2250 W. - Verify Ventilation
Verify that air inlets, test ports, drain areas, and controller surfaces are unobstructed.
What are the temperature uniformity specifications at low versus high temperature ranges for the BH-60CL chamber?
The chamber exhibits temperature fluctuation/uniformity of ±0.5°C at high temperature and ±1°C at low temperature, as stated in the technical specifications. This difference is due to the integrated sealed-compressor refrigeration system's performance at lower setpoints. Users should account for the wider tolerance when running low-temperature protocols.
Can the BH-60CL chamber be integrated with external monitoring or data logging systems?
Yes, the chamber supports optional RS485 communication interface and software for data logging, as well as embedded printer or thermal printer options. Additionally, an optional wireless alarm system and App control system enable remote status monitoring. These features are listed as optional accessories and must be specified at order.
What are the electrical and spatial requirements for installing the 72L constant temperature and humidity chamber?
The chamber requires a 2250W power supply at AC 220V, 50Hz. The external dimensions are 590 x 885 x 1380 mm, so installation space must accommodate these measurements with service access around the unit. The manual states to keep air inlets, test ports, and drain areas accessible for cleaning and maintenance.
The Atomfair AF-BH0060 (BH-60CL) 72 L constant temperature and humidity chamber provides a -10 to 100 °C range and 10% to 95% RH control using an imported capacitive humidity sensor and sealed-compressor refrigeration, suitable for pharmaceutical stability studies and materials conditioning. Its color touchscreen controller supports 100-program/1000-segment sequencing, while the 304 stainless steel interior and 50 mm test port facilitate clean, repeatable environmental testing.
Positive
- Wide humidity range with capacitive sensor: The 10%RH to 95%RH band and imported capacitive electronic humidity sensor eliminate wet-bulb maintenance, enabling continuous real-time monitoring for humidity-sensitive incubation, conditioning, and stability-study workflows.
- Programmable touchscreen with multi-segment control: The color touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycle steps with live curve display and multilingual interface, allowing precise staged method execution for complex test protocols.
Trade-offs
- High power draw for 72 L chamber: The 2250 W power requirement demands a dedicated AC 220 V, 50 Hz circuit and may limit placement in labs with constrained electrical infrastructure or shared outlets.
- Temperature uniformity varies with setpoint: Temperature fluctuation/uniformity is ±0.5 °C at high temperature but degrades to ±1 °C at low temperature, which may affect reproducibility in sub-ambient stability studies requiring tighter spatial control.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).