Temperature Humidity Chamber 500 L −40 to 100°C ATOMFAIR®

$26,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Programmable 500 L temperature and humidity chamber with -40 to 100°C control, 35-95%RH range, 0.1°C resolution and 3 shelves for stable testing. Order now.

SKU: AF-LE-E-BPSC-0500-CB50
Category:
Brands:

Programmable Touchscreen Constant Temperature and Humidity Chamber, 500 L,-40-100℃
Research-grade laboratory product
Product Overview

Programmable Touchscreen Constant Temperature and Humidity Chamber, 500 L,-40-100℃ is a programmable touchscreen constant temperature and humidity chamber built for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation. This configuration provides 500 l chamber volume, -40 to 100 C, 35%rh to 95%rh humidity control, imported 304 mirror-finish stainless-steel chamber interior and programmable color touchscreen controller with curve display and multi-language interface for stable day-to-day laboratory operation.

This family combines fluorine-free design, imported 304 stainless-steel inner chamber construction, balancing temperature-humidity control, test-port access and color-touchscreen editing as key chamber elements. The chamber combines balancing-control refrigeration system with multi-point safety protection with high-temperature humidity sensor for real-time monitoring, 3 shelves and an interior size of 670 x 720 x 1020 mm, supporting incubation, cultivation, climate simulation or conditioned test work where repeatable environmental control is important.

This range is intended for laboratories that want staged touchscreen programs, multilingual interface, stored curves, PID self-tuning and safety protection in one humidity-chamber platform. Installation planning can be based on the external size of 850 x 1100 x 1930 mm and the stated power requirement of 7850 W. Optional functions such as embedded printer; rs485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration allow the unit to be adapted for alarm notification, data output, programmable operation, atmosphere support or other application-specific requirements.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BCB0500
Manufacturer Model BPS-500CB
Capacity 500 L
Temperature Control Range -40 to 100 C
Temperature Resolution 0.1 C
Temperature Fluctuation / Uniformity High temperature: +/- 0.5 C; low temperature: +/- 1 C
Humidity Function 35%RH to 95%RH
Humidity Deviation +/- 3%RH
Controller programmable color touchscreen controller with curve display and multi-language interface
Chamber Material imported 304 mirror-finish stainless-steel chamber interior
Power / Input 7850 W
Power Supply AC 380 V, 50 Hz
Working Environment +5 to 30 C
Sensor Configuration high-temperature humidity sensor for real-time monitoring
Cooling System balancing-control refrigeration system with multi-point safety protection
Internal Dimensions 670 x 720 x 1020 mm
External Dimensions 850 x 1100 x 1930 mm
Shelves / Light Decks 3 shelves
Program Function Touchscreen controller supports up to 100 programs, 1000 segments and 999 cycle steps, with a maximum time setting of 99 h 59 min per segment
Configuration Note This 500-size CB configuration should be reconfirmed before shipment scheduling because it is commonly supplied as a special-order build
Optional Accessories and Functions embedded printer; RS485 communication interface and software; wireless alarm system; communication interface and embedded printer are alternative options that should be selected according to the required configuration
Performance Features
  • Color touchscreen operation helps simplify program editing, parameter review and real-time curve observation during chamber use. This improves parameter review, setpoint editing and day-to-day operation in controlled chamber workflows.
  • Large program capacity supports staged environmental methods that need repeated cycles and multiple segments. This supports staged test methods and repeatable laboratory workflows that need cycle-based control.
  • PID auto-tuning helps correct temperature and humidity deviations quickly for more stable chamber control. This supports humidity-sensitive incubation, cultivation, conditioning and stability-study applications.
  • Balancing-control refrigeration and imported stainless-steel chamber construction support reliable long-duration operation. This helps support repeated cleaning, chamber hygiene and long-duration laboratory use.
  • Independent alarm and protection functions cover over-temperature, overload, over-current, fan and compressor conditions. This helps maintain dependable low-temperature performance and stable chamber recovery during repeated use.
  • Optional communication, printer and wireless-alarm functions make it easier to store, replay and supervise chamber records. This reduces operational risk by helping protect samples and notifying operators when abnormal conditions occur.
APPLICATION SCOPE: Suitable for scientific research, biotechnology tests, pharmaceutical packaging, industrial raw-material studies and product lifetime evaluation in universities, research institutes, pharmaceutical quality-control laboratories, agricultural research programs and industrial test environments that require controlled chamber operation.
HANDLING: Confirm installation space against 850 x 1100 x 1930 mm, prepare the specified power supply, and keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance. Every unit is shipped with reinforced packaging to reduce movement and impact during transport; keep the packed chamber upright and use suitable lifting equipment during unloading and positioning.
IMPORTANT NOTICE: Confirm the exact controller type, lighting form, humidity function, communication option and accessory package before ordering. Any displayed amount refers to the chamber body only and does not include freight. Freight is quoted separately and should be confirmed according to the delivery location and shipping method.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires a dedicated AC 380 V, 50 Hz power supply with over-current protection and must be operated within an ambient temperature range of +5 to 30°C. The 304 stainless steel interior must be kept clean and accessible, and the unit must remain upright during transport and positioning.

  • Electrical Safety: The chamber is equipped with over-temperature, overload, over-current, fan, and compressor protection and requires a grounded power supply.
  • Operating Environment: The working environment must be maintained between +5 and 30°C with adequate ventilation around air inlets.
  • Chamber Integrity: The 304 mirror-finish stainless steel interior resists corrosion but requires regular cleaning with non-abrasive agents.
  • Installation Requirements: The chamber must be installed on a level surface with clearance for external dimensions of 850 x 1100 x 1930 mm and access to test ports and drain areas.

Follow these steps to install and prepare the chamber for operation. Ensure all safety precautions are observed during unpacking and positioning.

Required Equipment: Lifting equipment

  1. Confirm installation space
    Confirm installation space against the external dimensions of 850 x 1100 x 1930 mm.
  2. Prepare power supply
    Prepare the specified power supply of AC 380 V, 50 Hz with appropriate over-current protection.
  3. Unload and position chamber
    Use suitable lifting equipment to unload and position the chamber upright on a level surface.
  4. Ensure accessibility
    Keep air inlets, test ports, shelving, drain areas, doors and controller surfaces accessible for cleaning and maintenance.

How does the temperature uniformity differ between high and low temperature ranges for the 500 L chamber?

At high temperatures, uniformity is ±0.5°C; at low temperatures, it is ±1°C. This is based on the specification table which lists 'Temperature Fluctuation / Uniformity' as 'High temperature: +/- 0.5 C; low temperature: +/- 1 C'. The balancing-control refrigeration system and PID auto-tuning help maintain stability, but the low-temperature range inherently has wider tolerance.

Can this chamber achieve humidity levels below 35% RH?

No, the humidity control range is specified as 35%RH to 95%RH. The chamber uses a high-temperature humidity sensor and balancing humidity control, but it does not include dehumidification below 35%RH. For applications requiring lower humidity, consider optional accessories or a different configuration.

What are the power and installation requirements, and is this unit a standard stock item?

The chamber requires an AC 380 V, 50 Hz power supply with a 7850 W input. External dimensions are 850 x 1100 x 1930 mm. The configuration note states that this 500 L CB model is commonly supplied as a special-order build, so shipment should be reconfirmed before ordering. It is not a standard stock item. Ensure proper installation space and power availability.

The AF-LE-E-BPSC-0500-CB50 (BPS-500CB) is a 500 L programmable constant temperature and humidity chamber with -40 to 100°C and 35-95%RH control, featuring a color touchscreen with 100-program capacity, PID auto-tuning, and balancing-control refrigeration. It is suited for stability testing and incubation but requires 380V power and is a special-order configuration.

Positive

  • Large program capacity with PID auto-tuning: The touchscreen controller supports up to 100 programs, 1000 segments, and 999 cycles, with PID auto-tuning for rapid correction of temperature and humidity deviations, enabling stable, repeatable environmental test methods.
  • Balancing-control refrigeration and stainless-steel interior: The balancing-control refrigeration system with multi-point safety protection and imported 304 mirror-finish stainless-steel chamber interior ensure reliable long-duration operation, easy cleaning, and corrosion resistance for laboratory use.

Trade-offs

  • High power and voltage requirements: The unit requires 7850 W and AC 380 V, 50 Hz power supply, and a working environment of +5 to 30°C, which may necessitate dedicated electrical infrastructure and climate-controlled laboratory space.
  • Special-order build with lead-time implications: This 500 L CB configuration is commonly supplied as a special-order build requiring reconfirmation before shipment, potentially extending delivery timelines and requiring proactive ordering planning.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).