Professional Constant Temperature and Humidity Chamber, 800L,with Printer
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a dedicated AC 380 V, 50 Hz power supply with 8050 W capacity and must be installed in an environment maintained between +5 and 35 °C. Proper clearance around the unit is necessary for ventilation, maintenance access to air inlets, test ports, drain areas, and controller surfaces.
- Electrical Supply Requirement: The chamber must be connected to a dedicated AC 380 V, 50 Hz power supply rated for 8050 W peak load.
- Environmental Operating Range: The chamber must be installed in a location where ambient temperature remains between +5 and 35 °C to ensure stable operation.
- Installation Space and Clearance: Allow adequate clearance around the chamber for ventilation and maintenance access to air inlets, test ports, drain areas, and controller surfaces.
- Transport and Handling: During transport, keep the chamber upright and use suitable lifting equipment to unload and position the unit.
- Over-Temperature Protection: The independent over-temperature protection system will shut down the chamber and alert operators if abnormal conditions occur.
Follow these steps to safely install and prepare the chamber for first use. Complete each step in sequence to ensure proper operation and avoid damage.
Required Equipment: Suitable lifting equipment
- Transport the chamber upright
Keep the packed chamber upright during transport and use suitable lifting equipment for unloading. - Position the chamber
Use suitable lifting equipment to unload and position the chamber at the installation site. - Verify installation space
Confirm the installation space matches the external dimensions of 860 x 1340 x 1995 mm. - Connect power supply
Prepare and connect the chamber to a dedicated AC 380 V, 50 Hz power supply. - Ensure accessibility
Ensure all air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.
How does the temperature uniformity of the LHS-800HC-II 800L chamber differ between its high-temperature and low-temperature operating ranges?
The temperature uniformity specification varies with the set point: at high temperature (typically above ambient) the fluctuation is ±0.5°C, while at low temperature (near 10°C) it is ±1.0°C. This difference is critical for applications requiring tight control at elevated versus reduced temperatures, such as stability testing or material conditioning.
What power infrastructure is required to install and operate the Atomfair 800L constant temperature and humidity chamber?
The chamber requires a dedicated AC 380V, 50 Hz power supply with a rated input of 8050 W. This is a three-phase electrical connection, not a standard single-phase outlet, and must be confirmed during installation planning to avoid operational delays or safety issues.
What is the permissible ambient temperature range for the working environment to ensure stable chamber performance?
The chamber is specified to operate reliably in an ambient environment of +5 to 35°C. Exceeding this range can affect temperature and humidity control accuracy, making it essential to place the unit in a climate-controlled laboratory space.
The AF-LE-E-LHPR-0800-2800 (LHS-800HC-II) is an 800-liter constant temperature and humidity chamber with microcomputer balancing control, imported compressor and humidity sensor, and mirror-finish stainless-steel interior. It offers reliable environmental simulation for industrial research, biotechnology, and stability testing, but requires a 380V/8050W supply and spacious installation footprint.
Positive
- Microcomputer balancing control logic: The microcomputer temperature and humidity controller uses balancing control logic to maintain stable conditions, supporting repeatable environmental testing for incubation, cultivation, and stability studies.
- Imported compressor and sensor reliability: The chamber incorporates an imported compressor, air-circulation system, and humidity sensor, providing dependable long-term performance for humidity-sensitive laboratory applications.
Trade-offs
- High power and supply requirements: The unit requires 8050 W at AC 380 V/50 Hz, necessitating a dedicated high-power electrical infrastructure and pre-installation planning.
- Large footprint and limited temperature range: External dimensions of 860 x 1340 x 1995 mm demand significant lab space, and the temperature range (10 to 70°C) and humidity range (40% to 95% RH) may not cover all testing protocols.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).