160 L Standard Controller Water-Jacket Constant Temperature Incubator
Research-grade laboratory product
Product Overview

160 L Standard Controller Water-Jacket Constant Temperature Incubator is designed for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred. Water-jacket heating, stable holdover after power interruption, and glass inner door observation for constant temperature laboratory work. The configuration provides RT + 5 to 65 °C, 850 W rated power, a working chamber of 500 × 500 × 650 mm (W × D × H), and external dimensions of 650 × 640 × 950 mm (W × D × H).

The control and chamber design support practical laboratory operation: Standard controller or programmable LCD controller in N variants. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-WJIN-160A
Product Family Water-Jacket Constant Temperature Incubator
Configuration 160 L Standard Controller
Rated Operating Power 850 W
Working Chamber Size 500 × 500 × 650 mm (W × D × H)
Overall Dimensions 650 × 640 × 950 mm (W × D × H)
Model Configuration Standard controller
Heating Method Water-jacket heating
Temperature Control Range RT + 5 to 65 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.3 °C
Temperature Uniformity ±0.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Timing Range 0 to 5999 min
Power Supply AC 220 V, 50 Hz
Controller Options Standard controller or programmable LCD controller in N variants
Optional Accessories and Functions LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller
Performance Features
  • Water-jacket heating supports stable chamber temperature and better thermal holdover during power interruption according to the product design. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A glass inner door supports observation, and opening the door pauses operation and cuts heating and circulation fan activity. This helps balance temperature uniformity with sample protection during constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Automatic fan speed control adjusts airflow when the chamber reaches the set temperature. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • N variants include multi-step programmable control for more complex incubation processes. This supports controlled, repeatable operation for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Optional UV sterilization, automatic water filling, printer, U-disk export, and communication interface are listed for this family. This supports chamber hygiene and contamination-control routines for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
  • Alarm functions cover high temperature, over-temperature, low water, and extended door opening conditions. This helps operators identify abnormal conditions during unattended or extended constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred.
APPLICATION SCOPE: Suitable for constant temperature incubation, culture work, and laboratory workflows where water-jacket thermal stability is preferred in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 650 × 640 × 950 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: LCD or programmable controller; printer; U-disk data storage; RS485 interface and communication software; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Operate the incubator within the specified ambient temperature range of +5 to +35 °C and supply clean, stable AC 220 V 50 Hz power to ensure safe and reliable performance. Maintain adequate water level in the water jacket and avoid prolonged door openings to prevent thermal instability and activation of safety alarms.

  • Electrical Supply: Connect the incubator only to a grounded AC 220 V, 50 Hz power outlet with sufficient capacity for the 850 W rated load.
  • Ambient Conditions: Install the unit in a location with ambient temperature between +5 and +35 °C and with adequate ventilation to prevent overheating.
  • Water Jacket Maintenance: Monitor and maintain the water level in the water jacket to prevent low-water alarms and ensure consistent thermal performance.
  • Door Operation: Minimize the duration and frequency of door openings to avoid triggering the extended door alarm and to maintain temperature uniformity.
  • Transport and Handling: Keep the incubator upright during transport and use suitable lifting equipment to avoid impact damage to the water jacket and internal components.

Follow these steps to install and operate the incubator safely, ensuring proper thermal stability and compliance with alarm monitoring. All procedures are based on the manufacturer's guidelines for the standard controller configuration.

Required Equipment: Suitable lifting equipment (e.g., dolly or forklift)

  1. Confirm Installation Space and Power
    Confirm the installation space accommodates the 650 × 640 × 950 mm external dimensions and the power supply matches the 220 V, 50 Hz specification.
  2. Transport Incubator
    Transport the incubator upright using suitable lifting equipment to prevent impact damage.
  3. Position for Accessibility
    Position the incubator so that the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible for cleaning, inspection, and operation.
  4. Select Optional Accessories
    Select and install optional accessories (e.g., printer, UV sterilization, RS485 interface) according to the required workflow.
  5. Connect Power Supply
    Connect the power supply and verify the main power switch is off before connecting the cord.

How does the water-jacket heating system affect temperature recovery after the inner door is opened?

Opening the inner door pauses heating and circulation fan activity to protect samples from rapid temperature shifts, which deliberately extends recovery time. The product description does not specify a quantitative recovery duration, but the design prioritizes sample protection over rapid stabilization. This trade-off is inherent to the water-jacket method, which provides stable temperature holdover during power interruption.

Can the standard controller model AF-WJIN-160A be upgraded to a programmable LCD controller, and what additional accessories are available?

Yes, the standard controller can be replaced with a programmable LCD controller, as listed under controller options and optional accessories. Other available accessories include a printer, U-disk data storage, RS485 interface with communication software, UV sterilization, and an independent over-temperature controller. These options must be selected according to the required workflow before purchase.

What are the water-level monitoring and maintenance requirements for the water-jacket incubator?

The incubator includes a low-water alarm function to alert operators when the water jacket level is insufficient. An optional automatic water-filling accessory is available to simplify maintenance. The product description does not specify water volume, replacement intervals, or manual filling procedures, so periodic visual inspection and manual refilling are required unless the automatic option is installed.

The 160 L Standard Controller Water-Jacket Constant Temperature Incubator (model AF-WJIN-160A) provides water-jacket thermal stability with ±0.3°C fluctuation and ±0.5°C uniformity at 37°C, suitable for constant temperature incubation where ambient control is available, but lacks cooling capability and requires ambient temperature within +5 to +35°C.

Positive

  • Water-jacket thermal holdover: Water-jacket heating provides stable chamber temperature and better thermal holdover during power interruption, supporting sample integrity during short outages.
  • Automatic fan speed control: Fan speed automatically adjusts when the set temperature is reached, reducing airflow to maintain uniformity and minimize sample disturbance.

Trade-offs

  • No cooling capability: Temperature control range is RT+5 to 65°C, so the unit cannot cool below ambient temperature, limiting its use to heating-only incubation.
  • Ambient temperature restriction: Working ambient temperature must be between +5 and +35°C, constraining placement in unconditioned or extreme environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).