50 L Standard Controller Electric Heated Constant Temperature Incubator
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a stable ambient temperature between 5°C and 35°C and a grounded AC 220 V, 50 Hz power supply. The unit must be installed on a level surface with adequate clearance for ventilation and access to controls, ports, and internal components.
- Transport and Handling: Keep the unit upright during transport and use suitable lifting equipment to avoid impact damage.
- Power Supply: Connect only to a grounded outlet matching the rated voltage and frequency specified in the technical documentation.
- Ambient Conditions: Operate within the specified ambient temperature range of +5°C to +35°C to maintain temperature control accuracy.
- Accessibility and Maintenance: Maintain access to the chamber, sensors, shelves, filters, doors, and test ports for routine cleaning, inspection, and operation.
Install the incubator on a stable, level surface with adequate clearance for ventilation and access. Connect to the appropriate power supply, set the desired temperature, and allow the chamber to stabilize before loading samples.
Required Equipment: Incubator unit, Power cord (supplied), Temperature controller (standard or optional LCD)
- Inspect and Unpack
Inspect the incubator for any visible damage after removing the reinforced packaging. - Position the Incubator
Place the unit on a level surface that accommodates the external dimensions and allows unobstructed access to the control panel, doors, and rear ventilation. - Connect Power
Connect the power cord to a grounded AC 220 V, 50 Hz outlet and verify the main power switch is in the off position before turning on. - Set Temperature
Turn on the power and set the temperature controller to the desired setpoint within the range of RT+5°C to 65°C. - Stabilize Chamber
Allow the chamber to reach the set temperature and stabilize until the temperature display indicates steady state within the rated fluctuation of ±0.5°C. - Load Samples
Load samples onto the shelves, ensuring they do not obstruct the forced convection airflow or contact the chamber walls. - Monitor Operation
Monitor the temperature display and alarm indicators during operation, and verify that the optional over-temperature controller is active if installed.
What temperature stability and uniformity can I expect from the 50 L Atomfair electric heated incubator?
The incubator provides a temperature resolution of 0.1 °C and a fluctuation of ±0.5 °C over the control range of RT +5 to 65 °C. Stability is supported by a forced convection airflow system with an adjustable circulation fan, which improves chamber uniformity for routine incubation and culture work.
What are the ambient temperature and power supply requirements for installing this incubator?
The unit requires a working ambient temperature of +5 to +35 °C and a power supply of AC 220 V, 50 Hz, with a rated operating power of 300 W. External dimensions are 690 × 500 × 500 mm (W × D × H), so adequate bench space and access for cleaning and operation must be confirmed before installation.
Does the 50 L standard controller incubator include independent over-temperature protection?
Independent over-temperature protection is available as an optional accessory, not included in the standard configuration. If required for the workflow, the independent over-temperature controller must be selected at the time of order from the listed optional functions.
The 50 L Standard Controller Electric Heated Constant Temperature Incubator (AF-EHIN-050A) delivers forced convection airflow for improved temperature uniformity and response in the range RT+5 to 65°C, with optional independent over-temperature protection and programmable control. Its 300 W heating system and 415×360×355 mm chamber suit routine incubation and culture workflows, though the 220 V/50 Hz power requirement and ambient temperature dependency (5–35°C) impose infrastructure constraints.
Positive
- Forced convection airflow uniformity: Adjustable circulation fan drives forced convection, improving temperature response and chamber uniformity for repeatable incubation and culture work.
- Optional independent over-temperature protection: Available independent over-temperature controller provides a hardware-level safety cutoff, reducing risk of thermal runaway during unattended operation.
Trade-offs
- Limited temperature range: Usable range is RT+5 to 65°C with a working ambient of 5–35°C, excluding high-temperature applications and requiring stable room temperature for consistent performance.
- Single-phase AC 220V/50Hz power requirement: Power supply is fixed at AC 220 V, 50 Hz; laboratories with different mains voltage or frequency require a step-down transformer or frequency converter, adding infrastructure cost.