Constant Temperature Incubator AF-PTIN-350 250 W ATOMFAIR®

$900.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade constant temperature incubator with AF-PTIN-350 model, 350 × 300 × 400 mm chamber, RT + 5 to 80 °C control, 250 W power, and programmable LCD operation.

SKU: AF-LE-E-PTIN-9042-9042
Category:
Brands:

Precision Constant Temperature Incubator, 350 × 300 × 400 mm chamber with Programmable Control
Research-grade laboratory product
Product Overview

Precision Constant Temperature Incubator, 350 × 300 × 400 mm chamber with Programmable Control is designed for precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows. Precision temperature control, programmable operation, and fan speed management for stable constant temperature experiments. The configuration provides RT + 5 to 80 °C, 250 W rated power, a working chamber of 350 × 300 × 400 mm (W × D × H), and external dimensions of 505 × 635 × 600 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large-screen LCD controller with programmable operation. laboratory chamber construction

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Programmable controller; printer; U-disk data storage; RS485 interface; UV sterilization; independent over-temperature controller.

This equipment is suited to laboratories that need precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-PTIN-350
Product Family Precision Constant Temperature Incubator
Configuration 350 × 300 × 400 mm chamber
Rated Operating Power 250 W
Working Chamber Size 350 × 300 × 400 mm (W × D × H)
Overall Dimensions 505 × 635 × 600 mm (W × D × H)
Temperature Control Range RT + 5 to 80 °C
Temperature Resolution / Fluctuation 0.1 °C / ±0.2 °C
Temperature Uniformity ±1.5 °C at 37 °C
Working Ambient Temperature +5 to +35 °C
Power Supply AC 220 V, 50 Hz
Controller Large-screen LCD controller with programmable operation
Standard Shelves 2 shelves
Data Handling Optional U-disk, RS485, printer, and UV sterilization
Optional Accessories and Functions Programmable controller; printer; U-disk data storage; RS485 interface; UV sterilization; independent over-temperature controller
Performance Features
  • A programmable controller supports multi-step operation for complex temperature control processes. This makes real-time parameter review and routine operation easier in precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
  • Automatic circulation fan speed control helps balance chamber uniformity and sample protection. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A stainless-steel inner chamber and rounded internal corners support cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • This product family includes self-diagnosis support for fault identification on the LCD screen. This makes real-time parameter review and routine operation easier in precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
  • Optional printer, communication, and U-disk storage accessories support operating record management. This allows the configuration to match documentation, communication and monitoring needs in precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
  • Independent over-temperature alarm protection supports safer experimental operation. This helps operators identify abnormal conditions during unattended or extended precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows.
APPLICATION SCOPE: Suitable for precision constant temperature experiments, cultivation, sample holding, and programmable laboratory temperature workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 505 × 635 × 600 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Programmable controller; printer; U-disk data storage; RS485 interface; UV sterilization; independent over-temperature controller. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires an ambient temperature range of +5 to +35 °C and a stable AC 220 V, 50 Hz power supply. The stainless-steel chamber and rounded corners facilitate cleaning, but the unit must be kept upright during transport and positioned with adequate clearance for the 505 × 635 × 600 mm external dimensions.

  • Power Supply Constraint: The incubator operates on AC 220 V, 50 Hz power and draws a rated power of 250 W.
  • Ambient Temperature Constraint: The working ambient temperature must be maintained between +5 and +35 °C to ensure proper temperature control.
  • Transport and Positioning Constraint: The packed unit must be kept upright during transport and positioned with sufficient space for the 505 × 635 × 600 mm external dimensions.
  • Chamber Access Constraint: The chamber, sensors, shelves, filters, doors, test ports, and control interfaces must remain accessible for cleaning, inspection, and operation.

Confirm the installation space meets the 505 × 635 × 600 mm external dimensions and provide a stable AC 220 V, 50 Hz power supply. Configure the programmable controller for multi-step temperature workflows and verify chamber uniformity before loading samples.

Required Equipment: Large-screen LCD controller with programmable operation, Standard shelves (2 included), Optional printer, U-disk, RS485 interface, or UV sterilization accessory

  1. Inspect Installation Space
    Inspect the installation area to confirm it accommodates the 505 × 635 × 600 mm external dimensions and provides access to a stable AC 220 V, 50 Hz power outlet.
  2. Connect Power Supply
    Connect the incubator to the AC 220 V, 50 Hz power supply and verify the unit powers on without error.
  3. Set Temperature Parameters
    Set the desired temperature within the RT +5 to 80 °C range using the large-screen LCD controller's programmable interface.
  4. Verify Chamber Uniformity
    Verify chamber temperature uniformity at the set point using an external calibrated thermometer before loading samples.
  5. Load Samples onto Shelves
    Load samples onto the standard shelves, ensuring adequate airflow around each container for uniform temperature distribution.
  6. Enable Optional Accessories
    Enable optional accessories such as the printer, U-disk data storage, RS485 interface, or UV sterilization as required by the workflow.
  7. Monitor Operation via Controller
    Monitor the incubator operation through the LCD screen, checking for self-diagnosis messages or over-temperature alarms during unattended use.

How does the automatic circulation fan speed control affect temperature uniformity in the AF-PTIN-350 incubator?

The automatic circulation fan speed control balances chamber uniformity and sample protection. The incubator achieves a temperature uniformity of ±1.5°C at 37°C, as specified in the technical specifications. This feature allows the user to adjust airflow for different sample types, minimizing disturbance while maintaining uniform conditions.

Can the AF-PTIN-350 incubator be integrated with external data logging systems via RS485?

Yes, the incubator supports an optional RS485 interface for external communication, along with optional U-disk data storage and printer connectivity. These accessories enable operating record management and integration with laboratory data systems. The controller is a large-screen LCD with programmable operation.

What safety features protect samples during unattended operation in the AF-PTIN-350 incubator?

The incubator includes an independent over-temperature alarm that provides protection during unattended or extended runs. Additionally, it features self-diagnosis support that displays fault codes on the LCD screen. These safety functions help operators identify abnormal conditions before sample damage occurs.

The Precision Constant Temperature Incubator AF-PTIN-350 offers a 350×300×400 mm chamber with programmable control and a temperature range of RT+5 to 80°C, suitable for cultivation and constant temperature experiments. Its stainless steel interior and self-diagnosis support enhance laboratory usability, but the limited temperature range and ambient requirements restrict deployment in non-standard conditions.

Positive

  • Programmable multi-step controller: The large-screen LCD controller supports multi-step programming for complex temperature control processes, enabling repeatable incubation workflows.
  • Stainless steel chamber with rounded corners: The inner chamber is constructed from stainless steel with rounded internal corners, facilitating cleaning and maintenance to reduce contamination risk.

Trade-offs

  • Narrow temperature range: The incubator operates only from RT+5 to 80°C, limiting its use to moderate-temperature applications without sub-ambient or high-temperature capability.
  • Restricted ambient operating conditions: The working ambient temperature range is +5 to +35°C, requiring climate-controlled lab environments to maintain specification and performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).