Water-Jacket CO2 Incubator 170 L 90°C Touchscreen ATOMFAIR®

$9,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 170 L water-jacket CO2 incubator with UV and 90 °C sterilization, 700 W power, 0-20% CO2 control, touchscreen records, and 3 shelves.

SKU: AF-LE-E-RHRW-0170-1790
Category:
Brands:

170 L Water-Jacket UV plus 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
Product Overview

170 L Water-Jacket UV plus 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series is designed for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows. Touchscreen trend charts, CO2 control with optional O2 monitoring, and sterilization variants for advanced culture workflows. The configuration provides RT + 3 to 55 °C, 700 W rated power, a working chamber of 530 × 460 × 720 mm (W × D × H), and external dimensions of 684 × 700 × 960 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large touchscreen interface with curve display and record review. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching.

This equipment is suited to laboratories that need advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2H-1709
Product Family CO2 Incubator, High-End Touchscreen Series
Configuration 170 L Water-Jacket UV plus 90 °C Sterilization
Rated Operating Power 700 W
Working Chamber Size 530 × 460 × 720 mm (W × D × H)
Overall Dimensions 684 × 700 × 960 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
O2 Option Optional zirconia O2 control from 1% to 90%
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Controller Large touchscreen interface with curve display and record review
Optional Accessories and Functions Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching
Performance Features
  • The touchscreen controller supports trend curves, alarm review, and 72-hour running record lookup according to the product design. This makes real-time parameter review and routine operation easier in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Infrared CO2 sensing and optional O2 control support advanced gas-environment culture workflows. This allows the configuration to match documentation, communication and monitoring needs in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • RHP models use 90 °C high-temperature and high-humidity sterilization, while selected RWP(90) models add UV and 90 °C sterilization support. This supports chamber hygiene and contamination-control routines for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • An environmental temperature monitoring system and heated outer door support stable chamber control and reduced condensation. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional wireless alarm, account permissions, external temperature and CO2 monitoring, and automatic cylinder switching are listed. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Alarm coverage includes power failure, CO2 deviation, door opening, and multiple temperature sensor conditions. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
APPLICATION SCOPE: Suitable for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 684 × 700 × 960 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This document lists the environmental, safety, and operational constraints for the CO2 incubator. Adherence to these constraints ensures safe and reliable operation.

  • Power Supply Requirement: The incubator requires a stable AC 220 V, 50 Hz power supply and must be connected to a suitable outlet as specified in the technical specifications.
  • Ambient Temperature Constraint: The operating ambient temperature must be maintained between +5 and +30 °C to ensure proper temperature control.
  • Installation Space Requirement: The installation site must accommodate the external dimensions of 684 × 700 × 960 mm (W × D × H) with sufficient clearance for operation and maintenance.
  • Transport Orientation: During transport, the packaged unit must remain upright and be handled with suitable lifting equipment to prevent damage.
  • Safety Monitoring: The incubator includes alarm systems for power failure, CO2 deviation, door opening, and temperature sensor faults to alert operators to abnormal conditions.

This procedure outlines the initial setup and safe handling of the CO2 incubator. Follow these steps to ensure proper installation and prepare the unit for operation.

Required Equipment: Lifting equipment

  1. Transport the unit
    Transport the packaged unit upright using suitable lifting equipment to the installation site.
  2. Confirm installation conditions
    Confirm that the installation space accommodates the external dimensions of 684 × 700 × 960 mm and that the power supply is AC 220 V, 50 Hz.
  3. Verify accessibility
    Verify that the chamber, sensors, shelves, filters, doors, test ports, and control interfaces remain accessible for cleaning, inspection, and operation.
  4. Select optional accessories
    Select optional accessories, such as zirconia O2 control or humidity display, according to the required workflow.

What is the CO2 recovery time after a door opening for the 170 L water-jacket CO2 incubator?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications. This rapid recovery minimizes disruption to cell culture conditions.

Does the Atomfair CO2 incubator support hypoxic or hyperoxic cell culture with O2 control?

Yes, the incubator offers an optional zirconia O2 control system that can regulate oxygen from 1% to 90%, enabling hypoxic or hyperoxic cultivation. This option is part of the High-End Touchscreen Series and supports advanced gas-environment culture workflows.

What are the external dimensions and power supply requirements for installing the 170 L CO2 incubator?

The incubator has external dimensions of 684 × 700 × 960 mm (W × D × H) and requires a power supply of AC 220 V, 50 Hz with a rated power of 700 W. The working ambient temperature should be between +5 and +30 °C. Ensure adequate space for ventilation and access.

This 170 L water-jacket CO2 incubator with UV and 90°C sterilization provides fast CO2 recovery (≤3 min to 5% after 30 s door open) and stable temperature uniformity (±0.3°C at 37°C), suitable for advanced cell culture workflows, but requires a 220 V/50 Hz power supply and ambient temperature control between +5 and +30°C.

Positive

  • Fast CO2 recovery after door opening: CO2 concentration recovers to 5% within 3 minutes after a 30-second door opening, minimizing disruption to cell culture conditions.
  • Dual UV and 90°C sterilization: Combined UV irradiation and 90°C high-humidity sterilization provide robust contamination control for repeated chamber hygiene routines.

Trade-offs

  • Power supply constraint: Requires AC 220 V, 50 Hz power supply, which may not be compatible with 110 V or 60 Hz lab infrastructure.
  • Limited ambient temperature range: Operates only within +5 to +30 °C ambient temperature, restricting placement in unconditioned or high-temperature lab environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).