CO2 Incubator 240 L Gas-Jacket 90 °C Sterilization ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

240 L gas-jacket CO2 incubator with 90 °C sterilization, 1000 W power, ±0.1 °C stability, 0-20% CO2 control and touchscreen records. Order now.

SKU: AF-LE-E-RHRW-0240-24RH
Category:
Brands:

240 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
Product Overview

240 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series is designed for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows. Touchscreen trend charts, CO2 control with optional O2 monitoring, and sterilization variants for advanced culture workflows. The configuration provides RT + 3 to 55 °C, 1000 W rated power, a working chamber of 600 × 630 × 670 mm (W × D × H), and external dimensions of 790 × 840 × 940 mm (W × D × H).

The control and chamber design support practical laboratory operation: Large touchscreen interface with curve display and record review. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching.

This equipment is suited to laboratories that need advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2H-240G
Product Family CO2 Incubator, High-End Touchscreen Series
Configuration 240 L Gas-Jacket 90 °C Sterilization
Rated Operating Power 1000 W
Working Chamber Size 600 × 630 × 670 mm (W × D × H)
Overall Dimensions 790 × 840 × 940 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 3 to 55 °C
Working Ambient Temperature +5 to +30 °C
Temperature Uniformity ±0.3 °C at 37 °C
Temperature Stability ±0.1 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
O2 Option Optional zirconia O2 control from 1% to 90%
Relative Humidity Natural evaporation, 90% or higher, with optional humidity display
Controller Large touchscreen interface with curve display and record review
Optional Accessories and Functions Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching
Performance Features
  • The touchscreen controller supports trend curves, alarm review, and 72-hour running record lookup according to the product design. This makes real-time parameter review and routine operation easier in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Infrared CO2 sensing and optional O2 control support advanced gas-environment culture workflows. This allows the configuration to match documentation, communication and monitoring needs in advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • RHP models use 90 °C high-temperature and high-humidity sterilization, while selected RWP(90) models add UV and 90 °C sterilization support. This supports chamber hygiene and contamination-control routines for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • An environmental temperature monitoring system and heated outer door support stable chamber control and reduced condensation. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • Optional wireless alarm, account permissions, external temperature and CO2 monitoring, and automatic cylinder switching are listed. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
  • Alarm coverage includes power failure, CO2 deviation, door opening, and multiple temperature sensor conditions. This helps operators identify abnormal conditions during unattended or extended advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows.
APPLICATION SCOPE: Suitable for advanced cell culture, CO2-controlled incubation, optional O2-managed cultivation, and traceable incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 790 × 840 × 940 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Zirconia O2 control; humidity display; wireless alarm; account permissions; external temperature and CO2 monitoring; automatic cylinder switching. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a stable AC 220V 50Hz power supply and an ambient temperature between +5°C and +30°C to maintain specified performance. The unit must be installed in a location with sufficient clearance for the external dimensions of 790 × 840 × 940 mm and access to the chamber for cleaning and maintenance.

  • Transport Constraint: Transport the unit upright using suitable lifting equipment to avoid internal damage.
  • Power Supply Constraint: Ensure the power supply matches the required AC 220V 50Hz specification.
  • Ambient Temperature Constraint: Operate the incubator only in an ambient temperature range of +5°C to +30°C.
  • CO2 Concentration Constraint: Use a CO2 supply capable of maintaining concentrations between 0% and 20%.
  • Sterilization Constraint: Decontaminate the chamber using the 90°C high-temperature high-humidity sterilization cycle when required.

How quickly does the 240L gas-jacket CO2 incubator recover CO2 concentration after a door opening, and what uniformity can be expected at 37°C?

The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as stated in the specifications. Temperature uniformity is ±0.3°C at 37°C, and temperature stability is ±0.1°C, supported by the gas-jacket design and heated outer door to reduce condensation.

Can the Atomfair AF-CO2H-240G incubator support hypoxic cell culture with O2 control, and what optional accessories are required?

Yes, the incubator supports optional O2-managed cultivation via a zirconia O2 control system that can regulate O2 from 1% to 90%. This requires the optional Zirconia O2 control accessory. Additionally, optional humidity display, external temperature and CO2 monitoring, and automatic cylinder switching are available to support advanced gas-environment workflows.

What are the power supply and installation space requirements for the 240L gas-jacket CO2 incubator?

The incubator requires an AC 220V, 50Hz power supply with a rated operating power of 1000W. The external dimensions are 790 × 840 × 940 mm (W × D × H), and the working ambient temperature range is +5 to +30°C. Before installation, confirm available space and provide the required power supply.

The 240L Gas-Jacket CO2 incubator delivers tight temperature control (±0.3°C uniformity, ±0.1°C stability at 37°C) and rapid CO2 recovery (≤3 minutes to 5% after door opening), supporting reproducible advanced cell culture workflows. However, the 220V/50Hz power requirement and narrow ambient temperature range (+5 to +30°C) impose infrastructure and environmental constraints that must be verified before deployment.

Positive

  • Tight temperature uniformity and stability: At 37°C, the incubator maintains ±0.3°C uniformity and ±0.1°C stability, ensuring reproducible thermal conditions for sensitive cell culture applications.
  • Fast CO2 recovery after door opening: CO2 concentration recovers to 5% within 3 minutes following a 30-second door opening, minimizing disruption to the gas environment during sample access.

Trade-offs

  • Specific power supply requirement: The unit requires AC 220V/50Hz power, which may necessitate electrical infrastructure modifications in laboratories with 110V/60Hz or non-standard supply.
  • Limited ambient operating temperature range: The incubator is specified for ambient temperatures between +5°C and +30°C; operation outside this range may compromise temperature control accuracy.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).