190 L Gas-Jacket 90 °C Sterilization CO2 Incubator, High-End Touchscreen Series
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a dedicated AC 220 V, 50 Hz power supply and must be operated within an ambient temperature range of 5 to 30 °C. The packed unit must be kept upright during transport, and the chamber must remain accessible for cleaning and inspection.
- Power Supply Requirement: The incubator requires a dedicated AC 220 V, 50 Hz power supply with adequate capacity for the 750 W rated power.
- Ambient Temperature Range: The incubator must be operated within an ambient temperature range of +5 to +30 °C to maintain specified performance.
- Transport Orientation: The packed incubator must be kept upright during transport and handled with suitable lifting equipment to avoid internal damage.
- Sterilization Cycle Safety: The 90 °C sterilization cycle must be performed with the chamber empty and all internal components rated for high-temperature exposure.
- Chamber Accessibility: The chamber, sensors, shelves, filters, doors, and control interfaces must remain accessible for routine cleaning and inspection.
This procedure describes the initial installation and safety verification of the CO2 incubator. Follow these steps to ensure proper placement, power connection, and operational readiness.
Required Equipment: Lifting equipment
- Transport the incubator
Transport the packed incubator upright using suitable lifting equipment to the installation location. - Confirm space and power
Confirm the available space matches the external dimensions (708 x 710 x 1030 mm) and provide a dedicated AC 220 V, 50 Hz power supply. - Ensure accessibility
Ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces are accessible for cleaning, inspection, and operation.
What is the CO2 recovery time of the 190 L Gas-Jacket CO2 incubator after a door opening?
The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications.
Can the Atomfair AF-CO2H-190G incubator be used for hypoxic or hyperoxic cell culture experiments?
Yes, the incubator supports optional zirconia O2 control from 1% to 90%, allowing both hypoxic and hyperoxic culture conditions. This option must be specified at purchase as it is not included in the base configuration.
What are the space and power requirements for installing the 190 L CO2 incubator?
The incubator requires external dimensions of 708 × 710 × 1030 mm (W × D × H) and a power supply of AC 220 V, 50 Hz at 750 W. The working ambient temperature must be between +5 and +30 °C. Ensure the installation space allows access to the chamber, sensors, and controls as per the handling instructions.
The 190 L Gas-Jacket CO2 incubator (model AF-CO2H-190G) provides ±0.1°C temperature stability, ±0.1% CO2 accuracy with infrared sensor, and 90°C high-temperature sterilization, supporting advanced cell culture and optional O2-controlled cultivation with traceable monitoring via touchscreen interface.
Positive
- Infrared CO2 Sensing with Fast Recovery: CO2 control accuracy of ±0.1% and recovery to 5% within 3 minutes after a 30-second door opening ensure stable gas conditions during routine access.
- 90°C Sterilization for Contamination Control: High-temperature and high-humidity sterilization at 90°C supports chamber hygiene and reduces contamination risk in long-term culture workflows.
Trade-offs
- Ambient Temperature and Power Supply Requirements: The unit requires a working ambient temperature of +5 to +30°C and a dedicated AC 220 V, 50 Hz power supply, limiting placement and infrastructure compatibility.
- Optional Feature Dependence for Advanced Workflows: O2 control, humidity display, and wireless alarm are optional accessories; the base configuration does not include these functions, requiring separate selection and procurement.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).