CO2 Incubator 150 L Water-Jacket UV 950 W ATOMFAIR®

$7,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 150 L water-jacket CO2 incubator with UV sterilization, infrared sensing, 950 W power, 0-20% CO2 control and 3 shelves. Order now.

SKU: AF-LE-E-CHCW-0150-15CW
Category:
Brands:

150 L Water-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series
Research-grade laboratory product
Product Overview

150 L Water-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series is designed for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows. Infrared CO2 control with gas-jacket or water-jacket chamber options and sterilization variants for different culture workflows. The configuration provides RT + 5 to 55 °C, 950 W rated power, a working chamber of 500 × 500 × 650 mm (W × D × H), and external dimensions of 650 × 615 × 914 mm (W × D × H).

The control and chamber design support practical laboratory operation: laboratory controller. laboratory chamber construction The model includes 3 shelves.

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include Humidity display; printer; communication interface; gas regulator; optional HEPA filtration.

This equipment is suited to laboratories that need cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-CO2E-150W
Product Family CO2 Incubator, IR Sensor Economy Series
Configuration 150 L Water-Jacket UV Sterilization
Rated Operating Power 950 W
Working Chamber Size 500 × 500 × 650 mm (W × D × H)
Overall Dimensions 650 × 615 × 914 mm (W × D × H)
Shelf Configuration 3 shelves
Power Supply AC 220 V, 50 Hz
Temperature Control Range RT + 5 to 55 °C
Working Ambient Temperature +5 to +30 °C
CO2 Control Range 0 to 20%
CO2 Control Accuracy ±0.1% with infrared sensor
CO2 Recovery Time No more than 3 minutes to recover to 5% after a 30-second door opening
Temperature Recovery Time No more than 8 minutes to recover to 37 °C after a 30-second door opening
Relative Humidity Natural evaporation, 90% or higher
Optional Accessories and Functions Humidity display; printer; communication interface; gas regulator; optional HEPA filtration
Performance Features
  • Infrared CO2 sensing supports stable CO2 control in routine culture workflows. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Gas-jacket, water-jacket, UV sterilization, and 90 °C sterilization variants are available within this product family. This supports chamber hygiene and contamination-control routines for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Microbial filtration at the gas inlet helps reduce contamination risk in the chamber atmosphere. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Door heating, circulation control, and optional HEPA filtration support cleaner culture operation. This helps maintain cleaner chamber air for contamination-sensitive cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • Optional humidity display, printer, communication interface, and gas regulator accessories are listed. This allows the configuration to match documentation, communication and monitoring needs in cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
  • The family is described as a value-focused upgrade line for routine non-medical laboratory use. This supports controlled, repeatable operation for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows.
APPLICATION SCOPE: Suitable for cell culture, CO2-controlled incubation, and temperature-humidity-sensitive cultivation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 650 × 615 × 914 mm (W × D × H) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: Humidity display; printer; communication interface; gas regulator; optional HEPA filtration. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator must be operated in an ambient temperature range of +5 to +30°C with a dedicated AC 220 V, 50 Hz power supply. The installation site must provide sufficient clearance for the unit's external dimensions and allow access for cleaning and maintenance.

  • Transport Constraint: During transport, keep the packed unit upright and use suitable lifting equipment to prevent damage.
  • Accessibility Constraint: Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation.

This procedure covers the recommended installation and transport steps for the CO2 incubator to ensure safe setup and prevent damage. Follow these steps to prepare the unit for operation.

  1. Transport Upright
    Keep the packed unit upright during transport and use suitable lifting equipment to move it.
  2. Confirm Installation Space
    Confirm the available space against the 650 × 615 × 914 mm external dimensions before installation.
  3. Provide Power Supply
    Provide the required power supply of AC 220 V, 50 Hz according to the technical specifications.
  4. Maintain Accessibility
    Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation.

What is the CO2 recovery time specification for the 150 L water-jacket UV sterilization CO2 incubator after a 30-second door opening?

The CO2 recovery time is no more than 3 minutes to recover to 5% CO2 after a 30-second door opening, as stated in the technical specifications. This rapid recovery minimizes disruption to cell culture environments.

What optional accessories are available for monitoring and data communication on this CO2 incubator?

Optional accessories include humidity display, printer, communication interface, gas regulator, and optional HEPA filtration. These allow the incubator to be configured for data logging, remote monitoring, and enhanced air cleanliness.

What are the ambient temperature and power supply requirements for installing this incubator?

The incubator requires an ambient temperature range of +5 to +30 °C and a power supply of AC 220 V, 50 Hz. The external dimensions are 650 × 615 × 914 mm, so adequate space must be provided for installation and access.

The 150 L water-jacket CO2 incubator with infrared sensor provides rapid CO2 recovery (≤3 min to 5% after 30-s door opening) and temperature recovery (≤8 min to 37°C after 30-s door opening), supporting stable culture conditions. Operational constraints include a narrow ambient temperature range (+5 to +30°C) and reliance on natural evaporation for humidity control.

Positive

  • Fast CO2 recovery after door opening: CO2 recovery time no more than 3 minutes to 5% after a 30-second door opening, enabled by infrared sensor and gas control.
  • Rapid temperature recovery with water jacket: Temperature recovery time no more than 8 minutes to 37°C after a 30-second door opening, demonstrating effective thermal mass.

Trade-offs

  • Requires controlled ambient temperature: Working ambient temperature range is +5 to +30°C; operation outside this range may affect performance and requires climate-controlled laboratory environment.
  • Humidity via natural evaporation only: Relative humidity is achieved through natural evaporation with no active control; optional humidity display is available but not included, limiting precise humidity monitoring.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).