80 L Water-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator requires a controlled ambient environment of +5 to +30 °C and a stable AC 220 V, 50 Hz power supply. The unit must be kept upright during transport and positioned with adequate clearance for chamber access and maintenance.
- Environmental Requirements: Operate the incubator within an ambient temperature range of +5 to +30 °C to ensure specified temperature control performance.
- Power Supply: Connect the incubator to a dedicated AC 220 V, 50 Hz power source that meets the 680 W rated power requirement.
- Installation Clearance: Provide sufficient space around the 550 × 520 × 764 mm (W × D × H) unit to allow full door opening and access to the chamber, sensors, and control interfaces.
- Transport Orientation: Keep the packed incubator upright during transport and use suitable lifting equipment to prevent impact or tilting.
This procedure covers the initial setup, sterilization, and operational verification of the incubator for routine cell culture use. Follow these steps to ensure safe and reliable operation.
Required Equipment: CO2 gas supply with regulator, Cleaning supplies (lint-free cloth, 70% ethanol), Calibrated thermometer, CO2 analyzer
- Verify Installation
Confirm the incubator is placed on a level surface with adequate clearance and connected to a dedicated AC 220 V, 50 Hz power supply. - Connect Gas Supply
Connect the CO2 gas supply to the inlet port using a regulator and ensure the supply pressure is set according to the manufacturer's specifications. - Perform Sterilization Cycle
Run the UV sterilization cycle before first use to decontaminate the chamber interior and reduce microbial load. - Set Temperature and CO2
Set the temperature to 37 °C and the CO2 concentration to 5% using the control panel, and allow the chamber to stabilize. - Verify Recovery Times
Open the door for 30 seconds, close it, and confirm the temperature recovers to 37 °C within 8 minutes and CO2 recovers to 5% within 3 minutes. - Load Culture Vessels
Place culture vessels on the shelves, ensuring adequate airflow between them and avoiding overloading the chamber. - Monitor and Maintain
Regularly check the chamber temperature, CO2 concentration, and humidity, and clean the interior and door gaskets as needed to maintain performance.
What is the CO2 recovery time specification after a 30-second door opening for the 80L water-jacket incubator?
The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications for this water-jacket model.
Can this CO2 incubator be ordered with HEPA filtration and a communication interface?
Yes, optional HEPA filtration and a communication interface are listed as available accessories. Other optional functions include a humidity display, printer, and gas regulator to tailor the configuration to specific documentation and monitoring needs.
What is the maximum ambient temperature for reliable operation of this incubator?
The working ambient temperature range is specified as +5 to +30 °C. Operating the incubator outside this range may affect temperature control and recovery performance.
The 80 L water-jacket CO2 incubator with UV sterilization and IR sensor offers precise CO2 control (±0.1% accuracy) and rapid recovery times (CO2 ≤3 min, temperature ≤8 min), but relies on passive humidity control via natural evaporation and requires specific ambient (5–30°C) and power supply (220V/50Hz) conditions.
Positive
- Infrared CO2 sensing with ±0.1% accuracy: The infrared sensor provides stable CO2 control within ±0.1% accuracy, supporting repeatable culture conditions.
- Fast recovery after door opening: CO2 concentration recovers to 5% within 3 minutes and temperature to 37°C within 8 minutes after a 30-second door opening, minimizing disturbance to cultures.
Trade-offs
- Passive humidity control via natural evaporation: Relative humidity is achieved through natural evaporation only, without active humidification, which may lead to fluctuations in dry environments.
- Restricted ambient temperature and power requirements: The unit requires a working ambient temperature of 5–30°C and a specific power supply of AC 220V/50Hz, limiting installation locations without voltage regulation or HVAC.