26 L Water-Jacket UV Sterilization CO2 Incubator, IR Sensor Economy Series
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a controlled ambient environment of +5 to +30 °C and a stable AC 220 V, 50 Hz power supply. The unit must be kept upright during transport and positioned with adequate clearance for chamber, sensor, and filter access.
- Environmental and Power Requirements: Confirm the installation space accommodates the 440 × 410 × 544 mm external dimensions and that the power supply matches the specified AC 220 V, 50 Hz requirement.
- Transport and Positioning: Keep the packed unit upright during transport and use suitable lifting equipment to avoid impact or movement damage.
- Accessibility for Maintenance: Maintain access to the chamber, sensors, shelves, filters, doors, test ports, and control interfaces for cleaning, inspection, and operation.
This procedure covers the initial setup, power-on, and operational verification of the incubator for routine cell culture use. Follow these steps to ensure safe and repeatable incubation conditions.
Required Equipment: AC 220 V, 50 Hz power supply, CO2 gas supply with regulator (if used)
- Position the incubator
Place the incubator on a level surface with sufficient clearance for the external dimensions and access to the chamber, sensors, and controls. - Connect the power supply
Connect the incubator to a grounded AC 220 V, 50 Hz power outlet that matches the rated power of 250 W. - Set the temperature
Set the temperature controller to the desired setpoint within the range of RT + 5 to 55 °C, typically 37 °C for cell culture. - Set the CO2 concentration
Set the CO2 controller to the desired percentage within the 0 to 20% range, typically 5% for mammalian cell culture. - Verify recovery performance
After a 30-second door opening, confirm the CO2 level recovers to 5% within 3 minutes and the temperature recovers to 37 °C within 8 minutes. - Monitor humidity
Check that relative humidity reaches 90% or higher through natural evaporation, adding water to the humidity pan as needed. - Perform routine hygiene checks
Inspect and clean the chamber, shelves, and door gaskets regularly, and verify the UV sterilization function if contamination control is required.
How fast does the Atomfair AF-CO2E-026W CO2 incubator recover CO2 and temperature after a 30-second door opening?
The CO2 concentration recovers to 5% within 3 minutes, and the temperature recovers to 37 °C within 8 minutes after a 30-second door opening, as specified in the technical data. This rapid recovery supports stable conditions for cell culture workflows.
What optional accessories and functions are available to extend the monitoring and data logging capabilities of the 26 L water-jacket CO2 incubator?
The incubator supports optional humidity display, printer, communication interface, gas regulator, and HEPA filtration. These accessories enable real-time monitoring, data recording, and integration with laboratory information systems for contamination-sensitive cell culture applications.
What are the critical installation and handling requirements for the Atomfair 26 L water-jacket CO2 incubator?
The incubator requires an AC 220 V, 50 Hz power supply, an ambient temperature range of +5 to +30 °C, and a clear space for its external dimensions of 440 × 410 × 544 mm. During transport, it must be kept upright, use reinforced packaging, and be moved with suitable lifting equipment to prevent damage.
The 26 L water-jacket CO2 incubator with IR sensor provides precise CO2 control (±0.1% accuracy) and rapid recovery (3 minutes to 5% CO2 after door opening), but its limited temperature range (RT+5 to 55°C) and passive humidity control (natural evaporation) require careful lab environment planning for routine cell culture.
Positive
- Infrared CO2 sensor with rapid recovery: CO2 control accuracy of ±0.1% and recovery to 5% within 3 minutes after a 30-second door opening support stable, reproducible culture conditions.
- Water-jacket with UV sterilization: Water-jacket construction provides thermal stability and uniformity, while built-in UV sterilization offers an additional contamination control layer for routine cell culture workflows.
Trade-offs
- Narrow temperature and ambient range: Operating temperature limited to RT+5 to 55°C, with a required ambient temperature of +5 to +30°C, restricting use in hot environments or for high-temperature applications.
- Passive humidity control only: Relative humidity is achieved through natural evaporation (≥90% RH) without active regulation; optional humidity display does not provide control, which may be insufficient for humidity-sensitive cultures.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).