500 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The 500 L CO2 Incubator requires a stable AC 220 V, 50 Hz power supply and an ambient temperature range of +5 to +30 °C for reliable operation. Installation space must accommodate its 880 × 860 × 1500 mm external dimensions, and the unit must be kept upright during transport using suitable lifting equipment.
- Power Supply Constraint: The incubator must be connected to a dedicated AC 220 V, 50 Hz power outlet with proper grounding.
- Ambient Temperature Constraint: Operate the incubator only within an ambient temperature range of +5 to +30 °C to ensure stable temperature control.
- Installation Space Constraint: Provide a clear installation area that accommodates the external dimensions of 880 × 860 × 1500 mm (W × D × H) with adequate clearance for ventilation and access.
- Transport and Handling Constraint: Keep the packed incubator upright at all times and use suitable lifting equipment to prevent impact damage during transport.
These steps guide the installation, power connection, CO₂ supply setup, and initial sterilization of the incubator. Proper execution ensures safe operation and optimal cell culture conditions.
Required Equipment: Suitable lifting equipment, Gas regulator (optional accessory)
- Confirm Installation Site
Confirm that the installation site meets the space and power supply requirements specified in the technical specifications. - Unpack and Position
Unpack the incubator and place it on a level, stable surface at the prepared location. - Connect Power Supply
Connect the incubator to the AC 220 V, 50 Hz power supply using the provided power cord. - Connect CO₂ Supply
Connect the CO₂ supply line to the gas inlet using an appropriate regulator. - Set Operating Parameters
Set the desired temperature and CO₂ concentration on the LCD controller. - Initiate Sterilization Cycle
Initiate a 90 °C high-temperature and high-humidity sterilization cycle to prepare the chamber for use. - Verify Alarm Functions
Verify that the over-temperature, CO₂ deviation, and door-open alarms are functional before loading samples.
How quickly does the 500 L CO2 incubator recover CO2 concentration after a door opening?
The incubator recovers to 5% CO2 within no more than 3 minutes after a 30-second door opening, enabled by infrared CO2 sensing and gas-jacket PID control. This rapid recovery supports stable conditions during frequent door openings in cell culture workflows.
What sterilization method does the ATOMFAIR 500 L CO2 incubator use, and is it compatible with sensitive sensors?
The incubator uses a 90 °C high-temperature and high-humidity sterilization cycle that treats the chamber and internal components. The process is designed to inactivate contaminants without damaging the infrared CO2 sensor or other components, ensuring reliable operation after each cycle.
What are the power supply and ambient temperature requirements for the 500 L CO2 incubator?
The incubator requires AC 220V, 50Hz power supply with a rated power of 1450W. It operates in ambient temperatures from +5 to +30°C. Ensure the installation location meets these specifications and provides adequate space for the 880 × 860 × 1500 mm external dimensions.
This 500 L gas-jacket CO2 incubator provides IR-based CO2 control with ±0.1% accuracy and rapid recovery after door openings, plus a 90 °C high-humidity sterilization cycle and optional HEPA filtration for contamination-sensitive cell culture. Installation requires AC 220 V/50 Hz power, +5 to +30 °C ambient conditions, and 880 × 860 × 1500 mm floor space.
Positive
- IR CO2 sensing with rapid recovery: Infrared CO2 control maintains ±0.1% accuracy and restores 5% CO2 within 3 minutes after a 30-second door opening, supporting frequent-access cell culture workflows.
- 90 °C sterilization and inlet filtration: A 90 °C high-temperature, high-humidity sterilization cycle treats the chamber and internal components, while CO2 inlet microbial filtration and optional HEPA filtration help maintain cleaner chamber conditions.
Trade-offs
- Fixed 220 V/50 Hz power requirement: The incubator is specified for AC 220 V, 50 Hz at 1450 W rated power; laboratory electrical infrastructure must be confirmed as compatible before installation.
- Site and ambient prerequisites: External dimensions are 880 × 860 × 1500 mm, operating ambient must remain within +5 to +30 °C, and chamber, sensors, shelves, filters, doors, and test ports must stay accessible for routine cleaning and inspection.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).