190 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This incubator must be installed in a space that accommodates its external dimensions and provides a stable AC 220 V, 50 Hz power supply. Operation is restricted to ambient temperatures between +5 and +30 °C with chamber components kept accessible for cleaning and inspection.
- Power Supply Requirement: Connect the incubator only to the specified AC 220 V, 50 Hz power supply.
- Ambient Temperature Limit: Operate the incubator only within the stated working ambient temperature range of +5 to +30 °C.
- Chamber Access: Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation.
- Transport Orientation: Keep the packed unit upright during transport and use suitable lifting equipment to reduce movement and impact risk.
- Sterilization Cycle: Use the 90 °C high-temperature and high-humidity sterilization cycle to treat the chamber and internal components during maintenance.
Confirm the installation site accommodates the incubator's external dimensions and provides the specified AC 220 V, 50 Hz power supply before unpacking. Keep the packed unit upright during transport and use suitable lifting equipment to move it into position.
Required Equipment: Suitable lifting equipment
- Confirm Installation Space
Confirm that the installation space accommodates the incubator's external dimensions and provides access for cleaning and operation. - Transport Unit Safely
Keep the packed unit upright during transport and use suitable lifting equipment to move it into position. - Position Incubator
Position the incubator so that the chamber, sensors, shelves, filters, doors, test ports and control interfaces remain accessible. - Connect Power Supply
Connect the incubator to the specified AC 220 V, 50 Hz power supply. - Set Control Parameters
Set the temperature and CO2 control setpoints to the values required for the cell culture workflow. - Verify Recovery Performance
Verify that CO2 concentration recovers to 5% within no more than 3 minutes after a 30-second door opening. - Monitor Alarms
Monitor over-temperature, CO2 deviation, and prolonged door-opening alarms during unattended operation.
How quickly does the Atomfair AF-CO2C-190 CO2 incubator recover CO2 concentration after a 30-second door opening?
The CO2 recovery time is no more than 3 minutes to return to 5% CO2 after a 30-second door opening, as specified in the technical specifications. This rapid recovery is supported by the infrared CO2 sensor and gas-jacket PID control system.
What sterilization method does the 190 L Professional Cell Culture Series CO2 incubator use, and how does it affect workflow?
The incubator uses a 90 °C high-temperature and high-humidity sterilization cycle that treats the chamber and internal components. This allows for repeated cleaning and contamination control without requiring chemical agents, supporting dependable maintenance in cell culture workflows.
What are the power supply and ambient temperature requirements for operating the Atomfair AF-CO2C-190 incubator?
The incubator requires AC 220 V, 50 Hz power supply and an ambient working temperature range of +5 to +30 °C. The external dimensions are 708 × 710 × 1030 mm, so adequate space and ventilation must be provided. These infrastructure requirements must be reviewed before installation.
This 190 L CO2 incubator offers infrared CO2 sensing with rapid recovery (≤3 min to 5% CO2 after 30 s door opening) and a 90°C high-temperature sterilization cycle, but requires a 220 V 50 Hz power supply and relies on passive natural evaporation for humidity control, with optional display only.
Positive
- Infrared CO2 sensing with rapid recovery: Infrared CO2 sensor achieves ±0.1% control accuracy and recovers to 5% CO2 in under 3 minutes after a 30-second door opening, supporting stable conditions in frequent-access workflows.
- 90°C high-temperature sterilization cycle: A 90°C high-temperature and high-humidity sterilization cycle treats the chamber and internal components, enabling routine decontamination without chemical agents.
Trade-offs
- Fixed 220V 50Hz power requirement: The incubator is designed for AC 220 V, 50 Hz supply only, limiting direct deployment in regions with 110 V or 60 Hz infrastructure without a step-up transformer or frequency converter.
- Passive humidity control via natural evaporation: Relative humidity is maintained by natural evaporation, achieving ≥90% RH but without active control or feedback; optional humidity display is available but does not enable regulation.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).