155 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires an ambient temperature range of +5 to +30 °C and a stable AC 220 V, 50 Hz power supply. The 90 °C sterilization cycle and high-humidity operation necessitate chamber and sensor access for cleaning and inspection.
- Temperature Recovery Constraint: Temperature recovery to 37 °C after a 30-second door opening must not exceed 8 minutes.
- CO2 Recovery Constraint: CO2 recovery to 5% after a 30-second door opening must not exceed 3 minutes.
- Sterilization Cycle Constraint: The 90 °C high-temperature and high-humidity sterilization cycle requires the chamber to be empty and all internal components accessible.
- Installation Space Constraint: Installation requires a clear space accommodating the 670 × 767 × 880 mm external dimensions and accessible chamber, sensors, shelves, filters, doors, test ports, and control interfaces.
Confirm the installation space and power supply before unpacking. Perform the 90 °C sterilization cycle prior to first use to ensure chamber cleanliness.
Required Equipment: AC 220 V, 50 Hz power supply, Suitable lifting equipment for transport
- Verify Installation Space
Confirm the available space accommodates the 670 × 767 × 880 mm external dimensions and provides access to all chamber components. - Connect Power Supply
Connect the incubator to a stable AC 220 V, 50 Hz power outlet with the correct rated capacity. - Perform Sterilization Cycle
Initiate the 90 °C high-temperature and high-humidity sterilization cycle with the chamber empty to decontaminate internal surfaces. - Set Temperature and CO2 Parameters
Set the desired temperature within RT + 3 to 55 °C and CO2 concentration within 0 to 20% using the LCD display and PID controller. - Load Samples and Close Door
Place culture vessels on the shelves, ensuring even spacing for airflow, and close the inner glass and outer doors securely. - Monitor Recovery After Door Opening
Verify that temperature recovers to setpoint within 8 minutes and CO2 recovers to setpoint within 3 minutes after a door opening. - Enable Alarm Monitoring
Confirm that over-temperature, CO2 deviation, and prolonged door opening alarms are active for unattended operation.
What is the temperature uniformity and stability of the Atomfair 155 L CO2 incubator at 37°C?
The temperature uniformity is ±0.3°C at 37°C, and temperature stability is ±0.1°C, as specified in the technical specifications for the 155 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control.
What optional communication and data export options are available for this incubator?
Optional accessories include a printer and a communication interface for data export, along with an LCD display for real-time parameter review. These options support laboratory data logging and integration with external systems.
What are the external dimensions and power requirements for installing this 155 L CO2 incubator?
The external dimensions are 670 × 767 × 880 mm (W × D × H), and it requires AC 220 V, 50 Hz power supply with a rated power of 750 W. Adequate space and power should be confirmed before installation.
The 155 L CO2 Incubator (AF-CO2C-155) provides infrared CO2 sensing with ±0.1% accuracy and rapid recovery, plus 90°C sterilization, making it suitable for contamination-sensitive cell culture. However, it requires a controlled ambient temperature (5–30°C) and relies on passive humidity without active control.
Positive
- Infrared CO2 Sensing with Rapid Recovery: Infrared sensor provides ±0.1% CO2 control accuracy and recovers to 5% within 3 minutes after a 30-second door opening, supporting stable conditions during frequent access.
- 90°C High-Temperature Sterilization: A 90°C high-humidity sterilization cycle treats the chamber and internal components, enabling reliable decontamination between experiments.
Trade-offs
- Ambient Temperature Range Constraint: The incubator requires a working ambient temperature of +5 to +30°C, which may necessitate laboratory HVAC adjustment or location planning.
- Passive Humidity Without Active Control: Relative humidity is achieved by natural evaporation and is not actively controlled; humidity display is an optional accessory, limiting precise humidity management.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).