80 L CO2 Incubator, Professional Cell Culture Series with IR CO2 Control
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
Operate the incubator within the specified ambient temperature range of +5 to +30 °C and ensure the power supply matches AC 220 V, 50 Hz. Keep the chamber and internal components accessible for cleaning and periodically perform the 90 °C sterilization cycle to prevent contamination.
- Power Supply Requirements: The incubator requires a dedicated AC 220 V, 50 Hz power supply with proper grounding to avoid electrical hazards.
- Ambient Conditions: Maintain working ambient temperature between +5 and +30 °C to ensure stable temperature control and prevent overheating.
- Sterilization Protocol: Perform the 90 °C high-temperature and high-humidity sterilization cycle to treat the chamber and internal components before initial use and after contamination events.
- Transport and Handling: Keep the packed unit upright during transport and use suitable lifting equipment to avoid damage to the internal components.
- Accessibility for Maintenance: Ensure the chamber, sensors, shelves, filters, doors, test ports, and control interfaces are accessible for cleaning, inspection, and operation.
Follow these steps to install, sterilize, and set up the incubator for cell culture workflows. Ensure all safety checks are completed before introducing samples.
- Confirm Installation Space and Power
Verify the installation area provides at least 590 × 687 × 790 mm of clear space and a dedicated AC 220 V, 50 Hz power outlet. - Position and Level the Incubator
Place the incubator on a level, stable surface and ensure the chamber doors open freely without obstruction. - Connect Power and Check Display
Plug the power cord into the grounded outlet and turn on the main power switch, then confirm the LCD display activates. - Perform Sterilization Cycle
Initiate the 90 °C high-temperature and high-humidity sterilization cycle to decontaminate the chamber and internal components before first use. - Set Temperature and CO2 Parameters
Use the control panel to set the desired temperature, typically 37 °C, and CO2 concentration, typically 5%, for cell culture. - Allow Chamber to Stabilize
Wait for the temperature and CO2 levels to reach the set points, typically within 8 minutes for temperature and 3 minutes for CO2 after a door opening. - Monitor Alarms During Operation
Regularly check the alarm system for over-temperature, CO2 deviation, or prolonged door opening to ensure safe and stable incubation conditions.
How quickly does the AF-CO2C-080 CO2 incubator recover CO2 and temperature after a 30-second door opening?
The CO2 recovers to 5% in no more than 3 minutes, and the temperature recovers to 37°C in no more than 8 minutes after a 30-second door opening, as specified in the technical specifications. This rapid recovery supports frequent door-opening workflows in cell culture applications.
Can the AF-CO2C-080 be configured for low-oxygen (hypoxic) cell culture?
Yes, O2 control is available as an optional accessory for the AF-CO2C-080. The base model provides infrared CO2 control from 0 to 20%, and the optional O2 control module can be added to support hypoxic or low-oxygen incubation workflows.
What sterilization method does the AF-CO2C-080 use and how does it affect chamber maintenance?
The incubator uses a 90°C high-temperature and high-humidity sterilization cycle to treat the chamber and internal components. This allows repeated cleaning and decontamination without chemical disinfectants, reducing contamination risk and supporting routine laboratory maintenance.
This 80 L CO2 incubator features infrared CO2 sensing for rapid recovery (≤3 minutes to 5% CO2 after door opening) and 90°C high-temperature sterilization for contamination control, with noted constraints of a 220 V/50 Hz power requirement and a +5 to +30°C ambient temperature range.
Positive
- Fast CO2 recovery after door opening: Infrared CO2 sensing enables recovery to 5% CO2 in no more than 3 minutes following a 30-second door opening, supporting stable conditions in frequent-access workflows.
- 90°C high-temperature sterilization cycle: A 90°C high-temperature and high-humidity sterilization cycle treats the chamber and internal components, aiding decontamination and maintenance without chemical agents.
Trade-offs
- Ambient temperature range limitation: The incubator requires a working ambient temperature of +5 to +30°C, restricting placement to climate-controlled laboratory environments.
- Fixed AC 220 V, 50 Hz power supply: The unit operates on AC 220 V, 50 Hz only, which may require a dedicated circuit or voltage conversion in laboratories with incompatible electrical infrastructure.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.