The incubator requires a stable AC 220 V or 110 V, 50 Hz power supply and adequate clearance for the 668 × 675 × 752 mm external dimensions. Door recovery time must not exceed 5 minutes after a 30-second opening at 37 °C to maintain temperature uniformity.
- Power Supply Requirement: Confirm the available power supply matches the specified AC 220 V or 110 V, 50 Hz before installation.
- Spatial Clearance: Ensure the installation space accommodates the external dimensions of 668 × 675 × 752 mm for proper ventilation and access.
- Temperature Recovery Constraint: Maintain door openings to under 30 seconds to ensure the chamber recovers to set temperature within 5 minutes at 37 °C.
- Sensor Accuracy: Dual Pt100 sensors must be kept accessible for calibration to maintain temperature accuracy of ±0.2 °C.
Position the incubator on a level surface with adequate clearance and connect to the specified power supply. Configure the temperature setpoint and circulation fan settings via the 7-inch touchscreen controller before loading samples.
Required Equipment: 7-inch intelligent touchscreen controller, Adjustable shelves
- Position the Incubator
Place the incubator on a level, stable surface with at least 10 cm clearance around all sides for airflow. - Connect Power Supply
Connect the incubator to a grounded AC 220 V or 110 V, 50 Hz power outlet using the provided cable. - Set Temperature Parameters
Use the touchscreen controller to set the desired temperature within the 5 to 65 °C range and confirm the setpoint. - Adjust Circulation Fan
Set the adjustable circulation fan speed to balance chamber uniformity and sample protection from airflow. - Load Samples
Place samples on the adjustable shelves, ensuring they do not block the internal air circulation or sensors. - Verify Door Seal
Close the glass inner door and outer door firmly, then confirm the door recovery time is within 5 minutes at 37 °C. - Enable Alarms
Activate high and low temperature alarms via the controller to receive audible and visual notifications during operation.
What are the temperature control and recovery performance characteristics of the Atomfair 100 L semiconductor cooling incubator?
The Atomfair AF-SCLI-100 incubator provides a temperature control range of 5 to 65 °C with an accuracy of ±0.2 °C and uniformity of ±0.5 °C at both 37 °C and 25 °C. Door recovery time is specified as no more than 5 minutes after a 30-second opening at 37 °C, enabled by the Peltier semiconductor cooling and rapid recovery design.
Which optional communication and monitoring interfaces are available for the AF-SCLI-100 incubator?
The incubator supports optional printer or RS485 communication interface, USB data export, electronic signature function, and a smart App control system. These optional accessories and functions are selected according to the required workflow, as noted in the product's technical specifications.
What are the power supply requirements and alarm features of the 100 L semiconductor cooling incubator?
The incubator requires AC 220 V or 110 V, 50 Hz power supply. It includes high and low temperature alarms that provide audible and visual notification during operation. The chamber is constructed from 304 stainless steel with adjustable shelves and a glass inner door, and a password lock is standard for security.
The 100 L Semiconductor Cooling Low-Temperature Incubator (AF-SCLI-100) utilizes Peltier thermoelectric cooling for compressor-free temperature control from 5 to 65°C with ±0.2°C accuracy and ≤5 min door recovery, designed for low-temperature microorganism cultivation, sample storage, and plant breeding applications.
Positive
- Peltier Semiconductor Cooling System: Provides both cooling and heating without a compressor, enabling efficient low-temperature operation from 5 to 65°C with reduced mechanical complexity and vibration.
- Rapid Door Recovery: Recovers to set temperature within 5 minutes after a 30-second door opening at 37°C, supporting workflow continuity and sample stability.
Trade-offs
- Power Supply Requirements: Requires a dedicated AC 220V or 110V, 50Hz supply; lab must verify available voltage and circuit capacity before installation.
- Optional Accessories Not Included: UV sterilization, communication interfaces, USB export, and electronic signature must be ordered separately based on specific workflow needs.