Low-Temperature Biological Safety Incubator 120 L ATOMFAIR®

$5,000.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

120 L biological safety incubator with HEPA filtration, 4–65 °C control, ±0.1 °C stability, 1500 W power, and 304 stainless-steel chamber. Order now.

SKU: AF-LE-E-BSLT-0120-B100
Category:
Brands:

120 L Biological Safety Low-Temperature Incubator with HEPA Filtration
Research-grade laboratory product
Product Overview

120 L Biological Safety Low-Temperature Incubator with HEPA Filtration is designed for low-temperature biological safety cultivation, sample holding, microbiology work, and clean chamber incubation workflows. HEPA filtration, six-side heating, UV sterilization, and stainless-steel chamber construction for cleaner low-temperature cultivation workflows. The configuration provides 4 to 65 °C, with the minimum chamber temperature 20 °C below ambient, 1500 W rated power, a working chamber of 505 × 600 × 420 mm (W × H × D), and external dimensions of 693 × 875 × 753 mm (W × H × D).

The control and chamber design support practical laboratory operation: 7-inch color touchscreen controller. 304 stainless-steel chamber and shelves

The product supports repeatable incubation workflows through the family-specific control, airflow, sterilization, monitoring and alarm functions shown in the technical specifications. Available optional functions include 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system.

This equipment is suited to laboratories that need low-temperature biological safety cultivation, sample holding, microbiology work, and clean chamber incubation workflows, with installation, power supply, chamber access and selected configuration reviewed before use.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-BSLI-120
Product Family Biological Safety Low-Temperature Incubator
Configuration 120 L
Rated Operating Power 1500 W
Working Chamber Size 505 × 600 × 420 mm (W × H × D)
Overall Dimensions 693 × 875 × 753 mm (W × H × D)
Controller 7-inch color touchscreen controller
Temperature Control Range 4 to 65 °C, with the minimum chamber temperature 20 °C below ambient
Temperature Stability ±0.1 °C at 37 °C
Temperature Uniformity ±0.5 °C at 37 °C
Heating Method Six-side heating
Sterilization Method UV sterilization
Timing Range 0 to 5999 min
Standard Shelves 3 shelves
Power Supply AC 220 V, 50 Hz
Chamber Material 304 stainless-steel chamber and shelves
Optional Accessories and Functions 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system
Performance Features
  • The chamber includes a standard HEPA filter for filtering bacteria and dust particles from circulating air. This helps maintain cleaner chamber air for contamination-sensitive low-temperature biological safety cultivation, sample holding, microbiology work, and clean chamber incubation workflows.
  • Six-side heating helps reduce condensation inside the chamber and supports a cleaner cultivation environment. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • A color touchscreen controller presents set values and operating status in one screen. This makes real-time parameter review and routine operation easier in low-temperature biological safety cultivation, sample holding, microbiology work, and clean chamber incubation workflows.
  • A stainless-steel inner chamber and rounded internal corners support repeated cleaning and maintenance. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
  • USB data export, test-port access, password locking, and optional electronic signature and App monitoring support documentation workflows. This allows the configuration to match documentation, communication and monitoring needs in low-temperature biological safety cultivation, sample holding, microbiology work, and clean chamber incubation workflows.
  • An optional 90 °C high-temperature and high-humidity sterilization cycle can sterilize the inner chamber and internal components. This supports repeated cleaning, sample organization and dependable laboratory maintenance.
APPLICATION SCOPE: Suitable for low-temperature biological safety cultivation, sample holding, microbiology work, and clean chamber incubation workflows in universities, research institutes, quality-control laboratories and other scientific workflows where controlled incubation conditions are required.
HANDLING: Before installation, confirm the available space against the 693 × 875 × 753 mm (W × H × D) external dimensions and provide the required power supply shown in the technical specifications. Keep the chamber, sensors, shelves, filters, doors, test ports and control interfaces accessible for cleaning, inspection and operation. During transport, every incubator is protected with reinforced packaging to reduce movement and impact risk; keep the packed unit upright and use suitable lifting equipment.
IMPORTANT NOTICE: Select optional accessories and functions according to the required workflow: 90 °C high-temperature and high-humidity sterilization system; UV sterilization system; independent over-temperature controller; embedded printer; USB data storage; RS485 interface and communication software; electronic signature function; smart App control system. Any displayed amount refers to the incubator body only and does not include freight. Freight is quoted separately; please contact us for shipping confirmation.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The incubator requires a controlled environment with ambient temperature at least 20 °C below the set chamber temperature to achieve the minimum 4 °C operating point. HEPA filtration and UV sterilization are integral to maintaining chamber cleanliness for contamination-sensitive workflows.

  • Power Supply Requirement: The unit must be connected to an AC 220 V, 50 Hz power supply with sufficient capacity for the 1500 W rated operating power.
  • Installation Space Requirement: Installation requires clear floor space accommodating the 693 × 875 × 753 mm external dimensions with accessible clearance for chamber doors, test ports, and control interfaces.
  • Sterilization Compatibility: Optional 90 °C high-temperature and high-humidity sterilization cycle is compatible only when the corresponding accessory is installed and configured.
  • Transport Orientation Constraint: During transport, the packed incubator must remain upright and be handled with suitable lifting equipment to prevent internal damage.

This procedure covers initial installation, power connection, and basic operation of the incubator for low-temperature biological safety cultivation. Follow these steps to ensure proper chamber conditioning and workflow readiness.

Required Equipment: AC 220 V, 50 Hz power supply, 7-inch color touchscreen controller

  1. Position the Incubator
    Place the incubator on a level, stable surface with adequate clearance around the 693 × 875 × 753 mm footprint for door access and ventilation.
  2. Connect Power Supply
    Connect the unit to a dedicated AC 220 V, 50 Hz power outlet rated for at least 1500 W to ensure stable operation.
  3. Set Temperature Parameters
    Use the touchscreen controller to set the desired temperature within the 4 to 65 °C range, ensuring the ambient temperature is at least 20 °C below the set point.
  4. Activate Sterilization Cycle
    If using the optional high-temperature sterilization, initiate the 90 °C high-humidity cycle via the controller before loading samples.
  5. Load Samples onto Shelves
    Arrange samples on the 304 stainless-steel shelves, ensuring even spacing for uniform airflow and temperature distribution.
  6. Enable Monitoring Functions
    Configure USB data export or optional App monitoring to log chamber conditions for documentation and compliance.

What is the minimum chamber temperature achievable in a 25°C ambient room with this 120 L biological safety low-temperature incubator?

The incubator can achieve a minimum chamber temperature of 20°C below ambient, with a control range of 4 to 65°C. In a 25°C ambient room, the minimum achievable chamber temperature is 5°C, as specified by the temperature control range and the 20°C-below-ambient constraint.

How does six-side heating contribute to contamination control in this incubator?

Six-side heating heats all interior surfaces, reducing temperature gradients that cause condensation. This helps maintain a cleaner cultivation environment by minimizing moisture buildup, which is critical for contamination-sensitive workflows such as microbiology and clean chamber incubation.

What power supply specifications are required for installation of the AF-BSLI-120 incubator?

The incubator requires AC 220 V, 50 Hz power supply with a rated operating power of 1500 W. The source does not list support for 110 V or 60 Hz, so the power supply must be confirmed before installation to ensure compatibility.

This 120 L biological safety low-temperature incubator provides HEPA filtration, six-side heating, and a 304 stainless steel chamber for contamination-sensitive cultivation at 4–65 °C with ±0.1 °C stability, but requires a 220 V/50 Hz supply and its minimum temperature depends on ambient conditions (20 °C below ambient).

Positive

  • HEPA filtration for clean chamber air: Standard HEPA filter removes bacteria and dust from circulating air, supporting contamination-sensitive low-temperature biological safety cultivation and microbiology work.
  • Six-side heating reduces condensation: Heating on all six sides helps minimize internal condensation, maintaining a cleaner cultivation environment and supporting repeated cleaning and maintenance.

Trade-offs

  • Temperature range depends on ambient: Minimum chamber temperature is 20 °C below ambient, so achievable low temperatures are constrained by the laboratory environment; for example, at 25 °C ambient the minimum is 5 °C, not 4 °C.
  • Requires specific power supply: The incubator is specified for AC 220 V, 50 Hz only, which may require voltage conversion or dedicated circuit installation in regions with different mains power.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).