Three-Sided Strong-Light Climate Chamber, 1500 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires specific environmental conditions for safe and accurate operation. Failure to observe these constraints may affect performance or damage samples.
- Low-Temperature Ambient Limit: When set temperature is 10C or below, ambient temperature must not exceed 26C.
- Operating Environment Range: The work environment must remain within 5C to 40C and below 90% relative humidity.
- Installation Surface and Ventilation: Place the chamber on a level surface and ensure adequate ventilation space around the cabinet.
- Power Supply Requirement: The chamber requires a 2000W, AC220V 50Hz power supply connection.
Follow these steps to prepare the chamber for operation. Proper setup ensures reliable performance and sample safety.
- Keep Upright
Keep the chamber upright during unloading and positioning to prevent damage. - Level the Chamber
Place the chamber on a level surface to ensure stability and proper operation. - Verify Ambient Conditions
Confirm that the ambient temperature and humidity are within the specified operating limits of 5C to 40C and below 90%RH. - Ensure Ventilation
Leave enough ventilation space around the cabinet to allow adequate airflow.
Why is the temperature control range narrower in illuminated mode (10–60 °C) than in no-light mode (5–60 °C)?
The illuminated mode generates additional heat from the three-sided strong-light system, which raises the minimum achievable temperature. The product specification explicitly states a no-light range of 5 to 60 °C and an illuminated range of 10 to 60 °C, reflecting this thermal load. Researchers planning low-temperature light experiments must account for this 5 °C offset.
What ambient temperature constraint applies when operating the chamber at a set temperature of 10 °C or below?
When the set temperature is 10 °C or lower, the ambient room temperature must not exceed 26 °C. This condition is stated in the product's configuration note and performance data section. It is critical for maintaining stable low-temperature operation and preventing chamber overwork or drift.
What power supply and installation requirements must be met for the 1500 L climate chamber?
The chamber requires a 220 V, 50 Hz AC power supply with a 2000 W input. Installation requires a level floor, adequate ventilation space around the cabinet, and an ambient environment of 5–40 °C with relative humidity below 90 %RH. The unit weighs 480 kg and must be kept upright during transport and positioning.
The Atomfair Three-Sided Strong-Light Climate Chamber (1500 L) delivers 18000 lx from three sides and includes built-in humidification for high-temperature/high-humidity operation, but its ±2°C temperature uniformity and ambient temperature restrictions (≤26°C at low setpoints) require careful lab placement for reliable performance.
Positive
- Three-sided strong-light illumination: Three-sided lighting provides up to 18000 lx, supporting high-light cultivation and photoperiod experiments with repeatable conditions.
- Built-in humidification for high humidity: Integrated humidification enables high-temperature and high-humidity operation, useful for biological workflows and conditioning tasks requiring moisture control.
Trade-offs
- Temperature uniformity ±2°C: The specified ±2°C temperature uniformity may limit precision for experiments requiring tight thermal gradients across the 1500 L chamber.
- Ambient temperature constraints at low setpoints: When set temperature is 10°C or below, ambient temperature must not exceed 26°C; performance data are under no-load conditions, so real-world thermal loads may affect stability.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).