Four-Sided Programmable Climate Chamber 429 L ATOMFAIR®

$6,050.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 429 L climate chamber with 5–60 °C control, 50–90%RH humidity, four-sided 0–18000 lux lighting and programmable LCD control. Order now.

SKU: AF-LE-E-QHXF-0429-460F
Category:
Brands:

Four-Sided Programmable Climate Chamber, 429 L
Research-grade laboratory product
Product Overview

Four-Sided Programmable Climate Chamber, 429 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 429 l of usable space, 5 to 60 C, 50%rh to 90%rh humidity control and 0 to 18000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet combines a visible glass inner door, cleanable stainless-steel surfaces and a high-light four-side illumination layout for demanding plant-growth work. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and four-sided lighting, with an internal working room of 600 x 650 x 1000 mm and an external footprint of 845 x 1000 x 1875 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The four-sided lighting configuration gives a stronger illumination environment for cultivation and photoresponse tests while keeping the same programmable climate-control framework. The stated input power is 1200 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-QHX460F
Capacity 429 L
Temperature Control Range 5 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 1 C
Humidity Range 50%RH to 90%RH
Humidity Deviation +/- 8%RH
Light Intensity 0 to 18000 Lux (6 levels)
Lighting Faces 4 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 1200 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 600 x 650 x 1000 mm
External Dimensions 845 x 1000 x 1875 mm
Net Weight 219 Kg
Shelves / Trays 2 shelves
Program Function Programmable temperature, light, humidity and time control
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; performance data are measured under no-load conditions, ambient temperature 20 C and ambient humidity 50%RH
Optional Accessories and Functions RS485/232 interface and communication software; liquid crystal program controller; wireless alarm system; embedded printer
Performance Features
  • Four-sided illumination supports stronger and more even exposure for plant-growth work. This supports repeatable plant-growth and photoperiod experiments.
  • Programmable climate control helps coordinate temperature, light and humidity in one chamber. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • Mirror-finish stainless-steel surfaces and a glass inner door support observation and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Liquid crystal program control makes multi-step cycles easier to edit and review. This supports staged testing and repeatable control curves.
  • Wireless alarm, printer and communication options help document the process. This helps protect samples and alerts operators when abnormal conditions occur.
  • The family is suitable for experiments that need stronger lighting than the standard climate-chamber version. This supports repeatable plant-growth and photoperiod experiments.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber level, maintain stable ambient conditions and confirm the chosen control and accessory package before installation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. Performance notes are based on no-load testing at 20 C and 50%RH ambient humidity. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The chamber requires stable ambient conditions and a dedicated power supply to maintain specified performance. When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to prevent operational issues.

  • Ambient temperature constraint: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C.
  • Performance validation conditions: All performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity.
  • Installation requirements: The unit must be kept level on a stable surface with adequate clearance for ventilation and door operation.
  • Power supply specification: The chamber requires a 1200W, AC220V 50Hz power supply with proper grounding.
  • Transport and handling: The chamber must be transported upright and unpacked with care to avoid damage to internal components.

This procedure outlines the necessary steps for safely installing and initializing the climate chamber. Following these steps ensures proper operation and adherence to the chamber's environmental constraints.

  1. Unload upright
    Keep the chamber upright during unloading and positioning to prevent damage to the refrigeration system and glass door.
  2. Position level
    Place the chamber on a level surface and ensure stable ambient conditions with adequate clearance for airflow.
  3. Confirm configuration
    Confirm the selected control and accessory package before installation to ensure correct setup.
  4. Connect power
    Connect the chamber to a dedicated AC220V 50Hz power supply capable of 1200W continuous load.
  5. Verify ambient temperature
    If the set temperature is 10°C or below, verify the ambient temperature does not exceed 26°C to maintain performance.

What is the practical humidity control accuracy of the AF-QHX460F climate chamber, and how does the specified ±8%RH deviation affect experiments requiring tight moisture regulation?

The chamber's humidity control range is 50%RH to 90%RH with a deviation of ±8%RH. This means that at a setpoint of 70%RH, the actual humidity may vary between 62% and 78%RH. Users should anticipate this tolerance when designing experiments that require precise humidity stability, particularly for long-term plant growth or material testing where moisture levels are critical. The specification is stated under no-load conditions at 20°C and 50%RH ambient humidity.

Can the four-sided programmable climate chamber be integrated with external data logging or monitoring systems for remote experiment tracking?

Yes, the chamber supports optional RS485/232 interface and communication software, allowing integration with external data logging and monitoring systems. Additionally, an optional wireless alarm system and embedded printer are available for real-time alerts and documentation. These accessories must be specified at the time of configuration, as they are not included by default.

What are the critical ambient temperature limitations when operating the chamber at low set temperatures, and how does this affect laboratory placement?

When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain performance. This is a critical operational constraint that limits placement in labs with high ambient temperatures or near heat sources. The chamber's performance data are measured under no-load conditions at 20°C ambient temperature and 50%RH ambient humidity, so deviations from these conditions may affect actual performance. Users should ensure adequate environmental control in the lab, especially for cooling applications.

The AF-QHX460F four-sided programmable climate chamber provides 429 L of conditioned space with coordinated temperature (5–60 °C), humidity (50–90%RH), and six-level illumination up to 18,000 lux, making it well suited for plant-growth and photoresponse work; however, low-temperature set points require ambient temperatures no higher than 26 °C and humidity control is limited to the 50–90%RH band.

Positive

  • Four-sided illumination up to 18,000 lux: Four-face lighting delivers 0–18,000 lux in six levels for stronger and more even exposure in plant-growth, photoperiod, and photoresponse experiments.
  • Programmable temperature, light, humidity, time: The LCD microcomputer controller coordinates temperature, light, humidity, and time with a 0–9999 min timer range, supporting multi-step climate cycles for cultivation and conditioning workflows.

Trade-offs

  • Low-temperature set point ambient limit: When the set temperature is 10 °C or below, ambient temperature must not exceed 26 °C; performance data are measured under no-load conditions at 20 °C and 50%RH ambient humidity.
  • Humidity control limited to 50–90%RH: The chamber's humidity range is 50%RH to 90%RH with ±8%RH deviation, so it cannot provide drier conditions for applications requiring sub-50%RH environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).