Four-Sided Programmable Climate Chamber, 272 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
Operate the chamber only on a level surface within stable ambient conditions. When the set temperature is 10°C or below, ensure ambient temperature does not exceed 26°C to maintain performance.
- Ambient Temperature Limitation: When the set temperature is 10°C or below, ambient temperature must not exceed 26°C.
- Level Placement: Position the chamber on a level, stable surface to ensure proper operation.
- Upright Transport: Keep the chamber upright during unloading and positioning to avoid damage.
- Power Supply Requirement: Connect the chamber to a dedicated AC220V 50Hz power supply with a 1000 W capacity.
Position the chamber on a level surface and maintain stable ambient conditions. Confirm the control and accessory package before connecting to the power supply.
- Unload and Position
Keep the chamber upright during unloading and positioning to prevent damage. - Level the Chamber
Position the chamber on a level surface in a stable ambient environment. - Verify Ambient Conditions
Verify that the ambient temperature and humidity are within the recommended operating range. - Confirm Configuration
Confirm the control and accessory package configuration before installation.
What are the temperature uniformity and humidity deviation specifications for the Atomfair AF-QHX280F climate chamber under standard operating conditions?
The chamber achieves temperature uniformity of ±1°C and humidity deviation of ±8%RH under no-load conditions with an ambient temperature of 20°C and ambient humidity of 50%RH. These figures, measured according to the source, define the expected control precision for reproducible plant growth and tissue culture experiments.
What ambient temperature restriction applies when operating the AF-QHX280F chamber at low set temperatures?
When the set temperature is 10°C or below, the ambient room temperature must not exceed 26°C. This limitation, explicitly stated in the product documentation, is necessary to maintain proper temperature control and avoid performance degradation.
What power supply and installation space requirements are needed for the Atomfair AF-QHX280F climate chamber?
The chamber requires a single-phase AC220V 50Hz power supply with an input power of 1000 W. It has external dimensions of 800 x 900 x 1675 mm and a net weight of 182 kg, so a level, stable surface with adequate floor space and power infrastructure is essential. The source also advises keeping the unit level and maintaining stable ambient conditions.
The Atomfair AF-QHX280F is a 272 L four-sided illuminated climate chamber with programmable temperature, humidity, and light control, suitable for plant growth and cultivation. Key trade-offs include a restricted ambient temperature range at low set points and a ±8%RH humidity deviation that may limit use in high-precision applications.
Positive
- Four-sided uniform illumination: Four-sided lighting provides stronger and more even exposure for plant growth and photoperiod experiments, supporting repeatable cultivation conditions.
- Programmable multi-parameter control: LCD microcomputer controller enables coordinated programming of temperature, humidity, light intensity, and time for multi-step cycles and staged testing.
Trade-offs
- Ambient temperature constraint at low set points: When set temperature is 10 °C or below, ambient temperature must not exceed 26 °C to maintain specified performance; higher ambient conditions may cause instability.
- Moderate humidity control tolerance: Humidity deviation is ±8%RH, which may be insufficient for applications requiring tight moisture regulation, such as certain biological assays or material conditioning protocols.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.