Programmable Climate Chamber 600 L, 5-60 °C ATOMFAIR®

$4,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 600 L programmable climate chamber with 5-60 °C temperature control, 50-90%RH humidity, 0-10000 lux lighting and 1200 W input. Order now.

SKU: AF-LE-E-QHXT-0600-600T
Category:
Brands:

Programmable Climate Chamber, 600 L
Research-grade laboratory product
Product Overview

Programmable Climate Chamber, 600 L is a practical chamber for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection. It brings together 600 l of usable space, No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C, 50%rh to 90%rh humidity control and 0 to 10000 lux (6 levels) illumination, so the chamber can keep samples in a steady, repeatable working condition.

The cabinet uses top lighting, a visible glass inner door and a cleanable stainless-steel chamber to support both observation and repeatable environmental control. The cabinet uses a mirror-finish stainless-steel inner chamber, a tempered-glass inner door, a cold-rolled steel exterior and top lighting, with an internal working room of 675 x 800 x 1100 mm and an external footprint of 920 x 955 x 1795 mm. That combination of chamber size, shell build and liner material makes the unit easier to place, clean and use in routine laboratory work.

The series is designed to simulate natural climate conditions with programmable temperature, light and humidity control for plant and biological experiments. The stated input power is 1200 W, and the timer range is 0 to 9999 min. It is well suited to the day-to-day work listed above, including culture, incubation, climate simulation or illuminated growth tasks, depending on the family.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model AF-QHX600T
Capacity 600 L
Temperature Control Range No-light mode: 5 to 60 C; illuminated mode: 10 to 60 C
Temperature Resolution 0.1 C
Temperature Uniformity +/- 2 C
Humidity Range 50%RH to 90%RH
Humidity Deviation +/- 8%RH
Light Intensity 0 to 10000 Lux (6 levels)
Lighting Faces 2 faces
Controller LCD microcomputer programmable controller
Chamber Material Mirror-finish stainless-steel inner chamber
Exterior Shell Cold-rolled steel shell with electrostatic powder coating
Power / Input 1200 W
Power Supply AC220V 50Hz
Timer Range 0 to 9999 min
Internal Dimensions 675 x 800 x 1100 mm
External Dimensions 920 x 955 x 1795 mm
Net Weight 192 Kg
Shelves / Trays 2 shelves
Program Function Programmable temperature, light, humidity and time control
Configuration Note When set temperature is 10 C or below, ambient temperature should not exceed 26 C; when temperature setpoint is above 40 C, humidity setpoint should generally not exceed 80%
Optional Accessories and Functions RS485/232 interface and communication software; embedded printer; USB data storage; wireless alarm system; CO2 inlet; CO2 controller; light-intensity detection and control system
Performance Features
  • Programmable control of temperature, light, humidity and time supports simulated natural-climate workflows. This is useful for cultivation, conditioning and biological workflows that need moisture control.
  • The top lighting structure is useful for germination and plant-growth experiments. This supports repeatable plant-growth and photoperiod experiments.
  • Self-diagnosis, over-temperature self-limiting and power-off memory help protect the chamber and the samples. This helps preserve operation settings after power interruptions.
  • The embedded screen and menu-style operation make multi-parameter control easy to follow. This supports more reliable day-to-day chamber use.
  • Mirror-finish stainless-steel surfaces and a glass inner door support visibility and cleaning. This helps with cleaning, corrosion resistance and long-term laboratory use.
  • Multiple optional interfaces and atmosphere accessories extend the chamber to more advanced test methods. This supports more reliable day-to-day chamber use.
APPLICATION SCOPE: Suitable for plant growth, tissue culture, seed germination, cultivation, seedling raising, microbial culture and preservation, medicinal-material and building-material testing, insect rearing and quality inspection in universities, laboratories, research institutes and quality-control environments that need controlled chamber performance.
HANDLING: Keep the chamber away from direct heat sources, maintain stable room temperature and confirm the selected accessory package before installation. Every unit is shipped with reinforced packaging for transport safety; keep the unit upright during unloading and positioning.
IMPORTANT NOTICE: When the set temperature is 10 C or below, ambient temperature should not exceed 26 C. When the temperature setpoint is above 40 C, humidity setpoints should generally not exceed 80%. Performance notes are based on no-load testing at 20 C and 50%RH ambient humidity. Any quoted amount refers to the chamber body only and does not include freight. Freight should be confirmed separately according to the delivery destination.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

When the set temperature is 10°C or below, ambient temperature must not exceed 26°C to maintain stable chamber performance. When the temperature setpoint exceeds 40°C, humidity setpoints should generally not exceed 80% RH to prevent condensation or component stress.

  • Ambient Temperature Constraint: Maintain ambient temperature below 26°C when operating the chamber at setpoints of 10°C or lower.
  • High-Temperature Humidity Limit: Limit humidity setpoints to 80% RH or below when the chamber temperature exceeds 40°C.
  • Power Interruption Recovery: The power-off memory function preserves programmed settings after an unexpected power loss.
  • Over-Temperature Self-Limiting: The over-temperature self-limiting system protects samples and chamber components from thermal runaway.

Position the chamber away from direct heat sources on a level surface with adequate ventilation. Program temperature, humidity, light intensity, and time parameters via the LCD microcomputer controller before loading samples.

Required Equipment: LCD microcomputer programmable controller, Reinforced packaging for transport

  1. Position the chamber
    Place the chamber on a level, stable surface away from direct heat sources and ensure ambient temperature does not exceed 26°C for low-temperature operation.
  2. Connect power supply
    Connect the chamber to a grounded AC220V 50Hz power outlet rated for at least 1200 W.
  3. Program the controller
    Set temperature, humidity, light intensity, and time parameters using the LCD microcomputer programmable controller menu.
  4. Load samples
    Place samples on the stainless-steel shelves, ensuring adequate airflow around each item.
  5. Start the program
    Initiate the programmed cycle and verify that temperature, humidity, and light levels stabilize within the specified tolerances.

What are the ambient temperature and humidity limitations when operating the Atomfair AF-QHX600T climate chamber at extreme setpoints?

When the set temperature is 10 °C or below, the ambient temperature must not exceed 26 °C. When the temperature setpoint is above 40 °C, the humidity setpoint should generally not exceed 80% RH. These constraints are specified in the configuration notes to ensure reliable chamber operation.

Can the AF-QHX600T 600 L programmable climate chamber be integrated with external data logging or CO2 control systems?

Yes, the chamber supports several optional accessories including an RS485/232 interface with communication software, an embedded printer, USB data storage, a wireless alarm system, a CO2 inlet, a CO2 controller, and a light-intensity detection and control system. These options extend the chamber for advanced monitoring and atmosphere control.

What are the power, space, and handling requirements for installing the Atomfair AF-QHX600T climate chamber?

The chamber requires an AC220V 50 Hz power supply with 1200 W input. Its external dimensions are 920 x 955 x 1795 mm and net weight is 192 kg. It must be kept away from direct heat sources, maintained in a stable room temperature environment, and kept upright during unloading and positioning to avoid damage.

The Atomfair AF-QHX600T 600 L programmable climate chamber provides controlled temperature, humidity, and illumination for plant growth and biological experiments, with a top lighting design and stainless steel chamber. Its operating envelope includes constraints at low set temperatures requiring limited ambient temperature and at high set temperatures limiting humidity, which users must account for in experimental design.

Positive

  • Programmable multi-parameter control: The chamber supports programmable control of temperature, light, humidity, and time, enabling simulated natural-climate workflows essential for plant growth, tissue culture, and germination experiments.
  • Top lighting with visible glass door: Top-mounted illumination and a tempered-glass inner door allow unobstructed observation of samples while maintaining stable environmental conditions, and the mirror-finish stainless-steel chamber is easily cleaned and corrosion-resistant.

Trade-offs

  • Ambient temperature constraint at low setpoints: When the set temperature is 10°C or below, the ambient temperature must not exceed 26°C to maintain performance, requiring stable laboratory cooling infrastructure.
  • Humidity limitation at high temperature: At setpoints above 40°C, humidity should generally not exceed 80% RH, constraining high-temperature, high-humidity experiments and requiring careful experimental design.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).