Programmable LCD Light Incubator, 450 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a stable power supply of AC 220 V, 50 Hz and an ambient working environment of +5 to 30 °C. Continuous operation beyond 180 hours may require proper installation conditions to ensure reliable performance.
- Temperature Range: No-light mode operates from 4 to 50 °C; illuminated mode operates from 10 to 50 °C.
- Power Supply: Unit must be connected to AC 220 V, 50 Hz power source with a capacity of 2050 W.
- Working Environment: Ambient temperature must be maintained between +5 and 30 °C for proper operation.
- Continuous Operation: Recommended continuous operation schedule is not less than 180 hours under proper installation conditions.
- Over-Temperature Protection: Independent over-temperature alarm system stops the unit and alerts users when abnormal temperature conditions occur.
Confirm installation space and prepare the specified power supply before positioning the unit. Use suitable lifting equipment, keep the chamber upright, and ensure all access points are clear for maintenance.
Required Equipment: Suitable lifting equipment
- Confirm installation space
Confirm installation space against the external dimensions of 950 x 850 x 1850 mm. - Prepare power supply
Prepare the specified power supply of AC 220 V, 50 Hz with a capacity of 2050 W. - Position the chamber
Use suitable lifting equipment to unload and position the chamber, keeping it upright at all times. - Ensure access for maintenance
Ensure air inlets, test ports, shelving, drain areas, doors, and controller surfaces remain accessible for cleaning and maintenance.
What temperature range and illumination control does the 450 L programmable LCD light incubator provide?
In no-light mode the chamber controls from 4 to 50 °C; with illumination active the range narrows to 10 to 50 °C. Temperature resolution is 0.1 °C and fluctuation/uniformity is ±1 °C. Illumination is adjustable in six steps from 0 to 25000 lx using the LCD microcomputer controller.
Can the MGC-450BP light incubator be configured with CO2 control, data logging, or alarm accessories?
Yes, optional accessories include an RS232/485 communication interface and software, embedded printer, USB data storage, wireless alarm system, CO2 inlet, infrared CO2 controller, and light-intensity detection and control system. These options support documented workflows and alarm notification. No active humidity control is stated for this configuration.
What installation space, power supply, and operating environment are required for the 450 L light incubator?
Plan for external dimensions of 950 x 850 x 1850 mm and a 2050 W power requirement on AC 220 V, 50 Hz. The specified working environment is +5 to 30 °C, and continuous operation of not less than 180 hours is recommended under proper installation conditions. Keep air inlets, test ports, shelving, drain areas, doors, and controller surfaces accessible for cleaning and maintenance.
Programmable LCD light incubator with 450L capacity, 304 stainless steel interior, fluorine-free cooling, and programmable temperature/light control for microbial culture, plant cultivation, and seed testing. Requires 2050W, 220V/50Hz supply, and lacks active humidity control.
Positive
- Fluorine-free cooling with imported compressor: The fluorine-free cooling design with imported compressor and fan components supports efficient chamber running, long service life, and stable low-temperature performance during repeated use.
- 304 stainless steel interior with rounded corners: 304 stainless steel interior construction with rounded corners and removable shelving improves cleaning efficiency, chamber hygiene, and sample layout flexibility for long-duration laboratory use.
Trade-offs
- No active humidity control: This configuration does not include active humidity control, limiting its use in workflows requiring precise humidity regulation; users must rely on external monitoring or optional accessories.
- High power consumption and specific power supply: The unit requires 2050 W at AC 220 V, 50 Hz, which may necessitate a dedicated circuit and restricts installation to facilities with compatible electrical infrastructure.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).