Programmable LED Light Incubator, 800 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The incubator requires a 2700 W, 220 V 50 Hz power suppy and an ambent workng envirnment of +5 to 30 °C. The installation space must accommodate external dimensions of 1475 × 890 × 1780 mm with accessible service areas.
- Power Suppy Requirement: The incubator must be connected to a dedicated AC 220 V 50 Hz supply rated for 2700 W continuous load.
- Installation Space Requirement: The installation location must provide a minimum footprint of 1475 × 890 × 1780 mm with clearance for air circulation and service access.
- Ambient Operating Environment: The ambient temperature must remain within +5 to 30 °C to maintain specified performance and avoid compressor damage.
- Handling During Transport: Transport the chamber upright using suitable lifting equipment to prevent damage to compressors and internal components.
- Optional Accessory Pre-selection: Select all required optional accessories prior to ordering as post-installation modifications are not supported.
Follow these steps to position and connect the incubator for first use. Ensure that the installation space and power supply meet the specified requirements before unpacking.
Required Equipment: Suitable lifting equipment
- Confirm installation space
Confirm that the installation location provides the required 1475 × 890 × 1780 mm footprint with access to service areas. - Prepare power supply
Prepare a dedicated AC 220 V 50 Hz electrical outlet rated for 2700 W continuous load. - Transport chamber to site
Transport the packed chamber upright to the installation site using suitable lifting equipment.
Why does the temperature control range differ between lighting-on and lighting-off conditions in the Atomfair 800 L LED light incubator?
The temperature range is 10 to 50°C with lighting and 0 to 50°C without lighting because the LED lighting system generates heat, raising the minimum achievable temperature when lights are active. The unit uses two imported compressors with alternating operation for stable performance, but the lighting heat load limits the lower end under illuminated conditions.
How does the two-compressor alternating design support continuous long-duration operation in the Atomfair 800 L incubator?
The incubator uses two imported compressors that automatically alternate to prevent overheating or wear, enabling continuous chamber operation over weeks or months. This design supports dependable low-temperature performance and long-duration running stability, as stated in the performance features, and is key for uninterrupted cultivation programs.
Can the Atomfair 800 L LED light incubator be configured for CO2-enriched plant growth applications?
Yes, the unit supports an optional CO2 inlet and infrared CO2 controller, which enable atmosphere control for specialized plant-growth workflows. When the optional atmosphere-control package is selected, the chamber integrates the infrared CO2 sensor with the programmable controller, as specified in the technical specifications and optional accessories.
The Atomfair AF-M2B0800 Programmable LED Light Incubator provides 800 L capacity with dual-imported-compressor alternating operation for stable long-duration performance, but lacks active humidity control and requires 2700 W power supply, making it suitable for plant growth and climate-controlled cultivation where humidity is not critical.
Positive
- Dual alternating compressor design: Two imported compressors automatically alternate to support continuous long-duration operation, enhancing reliability for weeks-long cultivation programs.
- Multi-segment programmable control: 30 program segments allow independent temperature, humidity, light intensity, and time settings, enabling complex environmental profiles for incubation and stability studies.
Trade-offs
- No active humidity control: This configuration lacks active humidity control; humidity deviation is only specified as ±5%RH to 7%RH, limiting use in applications requiring precise moisture regulation.
- High power requirement: The unit consumes 2700 W at 220 V, 50 Hz, requiring dedicated electrical infrastructure and careful installation planning to avoid overloading circuits.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).