LED Plant Growth Chamber, 962 L
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, installation-space review, power-supply confirmation or configuration support, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The chamber requires a stable AC 220V, 50 Hz power supply with sufficient capacity (4300 W) and must be installed in a well-ventilated area with ambient temperature between 0 and 35°C. The unit must remain upright during transport and handling to prevent compressor damage and ensure long-duration reliability.
- Power Requirement: The chamber draws up to 4300 W and must be connected to a dedicated AC 220V, 50 Hz circuit.
- Ambient Operating Environment: The chamber is designed to operate in ambient temperatures from 0 to 35°C without additional cooling.
- Handling Constraint: The unit must be kept upright at all times during transport and unpacking to avoid damage to the dual compressors.
- Ventilation Requirement: Clearances around the chamber must allow unobstructed airflow through the air inlets and exhaust paths.
Follow these steps to safely install, power, and configure the chamber for first use. The procedure covers site preparation, unpacking, electrical connection, and controller programming to achieve stable environmental conditions.
Required Equipment: Suitable lifting equipment, Dedicated AC 220V, 50 Hz power supply
- Confirm site suitability
Confirm that the installation site provides the required clearances for the external dimensions of 870 x 1220 x 2060 mm and adequate ventilation. - Unpack chamber
Unpack the chamber using suitable lifting equipment while keeping the unit upright to avoid compressor damage. - Connect power
Connect the chamber to a dedicated AC 220V, 50 Hz power outlet rated for at least 4300 W. - Install shelves and light decks
Install the adjustable shelves and configure the three light decks according to the cultivation plan. - Program controller
Program the 7-inch touchscreen controller with the required temperature, lighting intensity, and time segments for the desired cultivation cycle. - Verify environmental set points
Verify that the internal chamber environment reaches the set points (5-45°C without light) before loading samples.
How does the LED lighting configuration affect the temperature control range of the 962 L plant growth chamber?
The temperature control range depends on the lighting load. Without light, the chamber operates from 5 to 45 °C. With single-layer light, the range shifts to 10 to 45 °C, and with double-layer light, it further narrows to 15 to 45 °C. This trade-off occurs because the high-output LED modules add heat load to the system, raising the minimum achievable temperature.
Does the standard AF-PGC0962 configuration provide active humidity control for plant growth studies?
No, this configuration does not include active humidity control. The specification notes 'No active humidity control stated for this configuration,' though the chamber does monitor humidity with a deviation of ±3%RH at 80%RH. For workflows requiring active regulation, an H-series configuration or optional CO₂ inlet and infrared CO₂ controller accessories may be considered, but explicit humidity control is not standard on this unit.
What are the power and space installation requirements for the 962 L LED plant growth chamber?
The chamber requires a 4300 W power supply at AC 220 V, 50 Hz. Externally, it measures 870 x 1220 x 2060 mm, so installation space must accommodate these dimensions while keeping air inlets, exhaust paths, and shelves accessible for maintenance. The working environment should be 0 to 35 °C, and the unit uses dual imported compressors with a long-duration operation design that may require adequate ventilation.
The LED Plant Growth Chamber, 962 L offers a large stainless-steel interior with modular LED lighting and dual-compressor cooling, but users must account for temperature range shifts due to lighting heat load and the lack of active humidity control in this base configuration.
Positive
- Large 962L capacity with modular LED lighting: The 962-liter working volume combined with three light decks and a circulation-air design supports uniform illumination across multiple layers, enabling scalable cultivation and climate simulation workflows.
- Dual imported compressors for long-duration stability: Dual imported compressors with energy-saving cooling control are designed for continuous operation, providing reliable low-temperature performance and stable environmental conditions for extended plant growth or incubation studies.
Trade-offs
- Temperature range shifts with active lighting: The temperature control range is 5 to 45°C without light, but shifts to 10 to 45°C with single-layer light and 15 to 45°C with double-layer light, requiring users to account for heat load from the LED modules when setting experimental conditions.
- No active humidity control in this base configuration: This LED lighting configuration lacks active humidity control; humidity deviation is only specified at ±3%RH at 80%RH, limiting its suitability for protocols that demand precise and independent humidity regulation.