316L Stainless Steel Powder-Sintered Filter Plate, 50 µm Filtration Rating, Ø50 × 5 mm, 30 PPI, 1/5/10 pcs
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For filtration-grade selection, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This document defines the operational limits and maintenance constraints for the 50 µm, 30 PPI 316L sintered filter plate. Adherence to these constraints is required to prevent media damage and maintain filtration performance.
- Pressure and Temperature Limits: Operate within a maximum working pressure of 3 MPa and a normal use temperature of 500 °C to avoid structural failure.
- Flow Direction Requirement: Direct flow from the outside surface toward the clean side to prevent pore blockage and media damage.
- Cleaning Compatibility: Select cleaning methods based on the retained material, using compatible options such as backwashing, backblowing, ultrasonic cleaning, or approved chemical agents.
- Handling Precautions: Avoid impact, scratching, or concentrated tool pressure on the porous surface to prevent compromising filtration integrity.
This procedure outlines the steps for initial installation, pressure ramp-up, and cleaning of the sintered filter plate. Following these steps ensures safe operation and extends the service life of the porous media.
Required Equipment: Clean filter housing, Pressure gauge, Backwashing or backblowing system, Ultrasonic cleaner (optional)
- Inspect the plate
Inspect the filter plate for any visible damage or contamination before installation. - Install the plate
Install the plate into the filter housing, ensuring the flow direction is from the outside surface toward the clean side. - Increase pressure gradually
Increase the system pressure gradually to the operating level, not exceeding the 3 MPa maximum working pressure. - Monitor filtration efficiency
Monitor filtration efficiency during operation and check for any pressure drop or flow reduction. - Initiate cleaning when efficiency drops
Initiate a validated backblowing or backwashing procedure if filtration efficiency falls below 50%. - Perform chemical cleaning if needed
Perform chemical cleaning with compatible agents such as dilute acid, dilute alkali, or surfactants if backwashing is insufficient. - Rinse and dry the plate
Rinse the plate thoroughly with clean fluid and dry it completely before storage or reuse.
What is the maximum working pressure and temperature for the 316L stainless steel powder-sintered filter plate with 50 µm filtration rating?
The maximum working pressure is ≤3 MPa, and the normal use temperature is ≤500 °C. These limits are based on the 316L stainless steel powder-sintered construction with a bulk density of 4.4–5.6 g/cm³ and porosity of 30–45%, as specified in the product technical specifications.
Can this 50 µm filter plate be cleaned and reused, and what cleaning methods are compatible?
Yes, the powder-sintered metallic media can be regenerated by compatible backblowing, backwashing, ultrasonic cleaning, or chemical cleaning procedures. The product description explicitly states that cleanable porous construction supports repeat use when surface damage, rapid pressurization, and incompatible cleaning chemicals are avoided.
What is the nominal pore spacing and porosity of the 30 PPI porous structure in this filter plate?
The 30 PPI porous structure has a nominal pore spacing of 0.85 mm and a porosity range of 30–45%. These parameters are directly stated in the technical specifications for the AF-SP30-C50 model, supporting particle retention while maintaining gas or liquid permeability.
This 316L powder-sintered filter plate offers a 50 µm filtration rating with a 30 PPI interconnected porous structure, enabling low initial resistance and cleanable reuse via backblowing or ultrasonic cleaning, while requiring careful pressure ramp-up and validated cleaning protocols to avoid damage.
Positive
- Cleanable metallic porous media: The powder-sintered 316L construction supports regeneration by backblowing, backwashing, ultrasonic cleaning, or compatible chemical procedures, enabling repeated use in laboratory and process filtration assemblies.
- High temperature and pressure tolerance: Rated for normal use up to 500 °C and a maximum working pressure of 3 MPa, the filter plate is suitable for elevated-temperature and moderate-pressure filtration applications without loss of structural integrity.
Trade-offs
- Mechanical handling sensitivity: The porous surface must be protected from impact, scratching, or concentrated tool pressure; pressure must be increased gradually to avoid structural damage, and filtration efficiency below 50% requires validated backblowing or backwashing procedures.
- Pre-order compatibility verification required: Filtration rating, PPI, porosity, through-pore requirement, flow, working pressure, temperature, and media compatibility must be confirmed before ordering, as the through-pore rate is not specified and depends on the operating conditions.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).