316L Stainless Steel Powder-Sintered Filter Plate, 50 µm Filtration Rating, Ø100 × 25 mm, 20 PPI, 1/2 pcs
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For filtration-grade selection, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This document outlines operational constraints for the 316L stainless steel powder-sintered filter plate. Adherence to these limits ensures safe and effective filtration performance.
- Temperature Limit: The normal use temperature must not exceed 500°C.
- Pressure Limit: The maximum working pressure must not exceed 3 MPa.
- Flow Direction: Flow should be directed from the outside surface toward the clean side.
- Cleaning Compatibility: Cleaning must use compatible methods such as backblowing, backwashing, ultrasonic, or chemical cleaning.
- Handling Precautions: Avoid impact, scratching, and rapid pressurization to prevent damage to the porous structure.
This procedure guides safe installation, operation, and cleaning of the filter plate. Follow each step to maintain filtration efficiency and avoid damage.
Required Equipment: Backwashing system, Backblowing system, Ultrasonic cleaner
- Confirm compatibility
Confirm the filter plate's filtration rating, dimensions, and operating conditions against your system requirements before installation. - Install with correct flow direction
Install the plate ensuring flow direction is from the outside surface toward the clean side. - Gradually increase pressure
Increase the operating pressure gradually to avoid damaging the porous structure. - Monitor filtration efficiency
Monitor filtration efficiency and if it falls below 50%, initiate a cleaning procedure. - Select cleaning method
Select a cleaning method based on the retained material and process medium, such as backwashing, backblowing, ultrasonic, or chemical cleaning. - Handle with care
Handle the plate with care to avoid impact, scratching, or concentrated tool pressure on the porous surface.
What is the maximum working pressure and temperature for the 316L powder-sintered filter plate with 50 µm rating?
The filter plate has a normal use temperature of ≤500 °C and a maximum working pressure of ≤3 MPa. These limits apply to the Ø100 × 25 mm, 20 PPI, 316L stainless steel powder-sintered construction, which maintains mechanical rigidity and stable pore structure within these operating conditions.
Can this 50 µm sintered filter plate be cleaned and reused, and what methods are compatible?
Yes, the metallic porous body supports regeneration through backblowing, backwashing, ultrasonic cleaning, and suitable chemical cleaning procedures such as dilute acid, dilute alkali, oxidizing agents, surfactants, or enzymes. The manufacturer advises avoiding impact, scratching, concentrated tool pressure on the porous surface, and incompatible cleaning chemicals to maintain reusability.
What is the difference between the 50 µm filtration rating and the 20 PPI pore density on this filter plate?
The 50 µm filtration rating specifies the particle size retained by the sintered powder structure, while the 20 PPI (pores per inch) describes the macro-porous spacing with a nominal pore spacing of 1.27 mm. The 20 PPI structure provides interconnected flow paths with 30–45% porosity and 4.4–5.6 g/cm³ bulk density, supporting permeability alongside the precise particle retention defined by the 50 µm rating.
This Ø100 × 25 mm 316L powder-sintered filter plate combines a 50 µm filtration rating with a 20 PPI interconnected pore structure for cleanable liquid and gas filtration, but requires upfront confirmation of process conditions and careful regeneration to maintain performance.
Positive
- Sintered 316L with interconnected through-pore network: The 50 µm filtration rating and 20 PPI structure provide stable pores, 1.27 mm nominal pore spacing and 30–45% porosity, supporting particle retention with low initial resistance during gas or liquid passage.
- Reusable, weldable self-supporting porous plate: Rigid 316L construction can be welded, bonded or mechanically integrated, and regenerated by backblowing, backwashing, ultrasonic or compatible chemical cleaning for repeat service.
Trade-offs
- Requires process-condition confirmation before installation: Flow, working pressure, temperature, media compatibility, through-pore requirement and dimensional tolerance must be confirmed before ordering because through-pore rate depends on required flow and pressure conditions.
- Needs careful operation and validated cleaning: Pressure must be increased gradually; if filtration efficiency falls below 50%, a validated backblowing or backwashing procedure is required. Avoid impact, scratching or concentrated tool pressure on the porous surface, and use compatible cleaning chemicals.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).