316L Stainless Steel Powder-Sintered Filter Plate, 20 µm Filtration Rating, Ø100 × 25 mm, 20 PPI, 1/2 pcs
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For filtration-grade selection, dimensional confirmation, material compatibility or custom configuration review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Operating pressure, temperature, compatibility, and cleaning constraints for this 316L sintered filter plate are defined in this document. These constraints apply only to the Ø100 × 25 mm, 20 µm, 20 PPI variable product configuration.
- Operating Limits: Keep normal use temperature at or below 500 °C and maximum working pressure at or below 3 MPa.
- Process Compatibility: Confirm target flow, working pressure, temperature, media compatibility, and through-pore requirements before installation or ordering.
- Pressure Handling: Increase pressure gradually and avoid rapid pressurization to protect the sintered porous structure.
- Cleaning Compatibility: Select cleaning methods compatible with the retained material and process medium, including clean-fluid backwashing, clean-gas backblowing, ultrasonic cleaning, dilute acid or alkali, oxidizing agents, surfactants, or enzymes.
- Surface Protection: Avoid impact, scratching, or concentrated tool pressure on the porous surface during cleaning and handling.
This procedure covers installation, pressure ramp-up, and regeneration cleaning for the Atomfair AF-SP20-A20 sintered filter plate. Only source-stated operational actions are included to avoid unsupported maintenance guidance.
Required Equipment: Clean-fluid backwashing system, Clean-gas backblowing system, Ultrasonic cleaner, Validated chemical cleaning agents
- Verify compatibility
Verify that the process medium, working pressure, temperature, and through-pore requirement are compatible with the 316L filter plate before installation. - Install with correct flow direction
Install the plate in the filter housing with flow from the outside surface toward the clean side. - Ramp pressure gradually
Increase the differential pressure gradually during startup to avoid rapid pressurization. - Regenerate the filter
Initiate a validated backblowing or backwashing procedure when filtration efficiency falls below 50%. - Clean the porous surface
Clean the porous surface using a compatible physical or chemical method while avoiding impact, scratching, or concentrated tool pressure.
What is the maximum working pressure and temperature for the 316L stainless steel powder-sintered filter plate with 20 µm rating?
The filter plate has a maximum working pressure of ≤3 MPa and a normal use temperature of ≤500 °C. These limits are based on the 316L stainless steel powder-sintered construction, which provides mechanical rigidity and elevated-temperature service capability for liquid, gas, and process-filtration assemblies.
Can this 20 µm sintered filter plate be cleaned and reused, and what cleaning methods are compatible?
Yes, the powder-sintered metallic media is cleanable and reusable. Compatible cleaning methods include backblowing, backwashing, ultrasonic cleaning, and chemical cleaning with dilute acid, dilute alkali, oxidizing agents, surfactants, or enzymes. Avoid surface damage, rapid pressurization, and incompatible cleaning chemicals to maintain performance.
What are the key dimensional and structural specifications of the Ø100 × 25 mm 20 PPI filter plate?
The filter plate has a diameter of 100 mm and thickness of 25 mm, with a 20 PPI porous structure providing 1.27 mm nominal pore spacing, 30–45% porosity, and 4.4–5.6 g/cm³ bulk density. The 316L material density is 8.0 g/cm³, and the plate features uniform interconnected flow-through pores for stable gas or liquid passage with low initial resistance.
This 316L stainless steel powder-sintered filter plate provides 20 µm filtration with a 20 PPI porous structure, offering low initial resistance and regenerability via backblowing, backwashing, ultrasonic, or chemical cleaning. The porous surface is fragile, requiring careful handling, and operating conditions must be pre-verified for compatible application.
Positive
- Low Initial Resistance with Uniform Pores: The uniform interconnected pore network supports stable gas or liquid passage with low initial resistance, reducing pressure drop across the filter plate.
- Multiple Regeneration Options: The powder-sintered metallic media can be regenerated by compatible backblowing, backwashing, ultrasonic cleaning, or chemical cleaning, enabling repeated use.
Trade-offs
- Fragile Porous Surface Requires Careful Handling: The porous surface can be damaged by impact, scratching, or concentrated tool pressure; pressure must be increased gradually and a validated cleaning procedure used if filtration efficiency drops below 50%.
- Pre-Verification of Operating Conditions Required: Flow rate, working pressure, temperature, media compatibility, through-pore requirement, and dimensional tolerance must be confirmed before ordering to ensure proper fit and performance.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).