SpectraCore UV 3102 UV-Visible Spectrophotometer, 190-1100 nm, 2.0 nmProduct Type: UV-Visible Spectrophotometer
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Operate the instrument within the specified voltage range and in a clean, dry environment to maintain optical stability. Avoid direct exposure to the UV light source to prevent eye or skin injury.
- Electrical Safety: Connect the instrument to a grounded power outlet matching the rated voltage and frequency to prevent electrical hazards.
- Optical Radiation Hazard: Ensure the sample compartment lid is closed during operation to contain UV radiation from the deuterium lamp.
Initialize the instrument by powering on and allowing the lamps to warm up for at least 30 minutes. Configure the measurement parameters and place the sample in the cell holder for analysis.
Required Equipment: Cuvette for sample, Power cable
- Power On
Press the power switch on the rear panel and wait for the touch screen to initialize. - Set Parameters
Select the wavelength range, bandwidth, and measurement mode from the touch screen interface. - Run Measurement
Place the cuvette in the 4-position cell holder and press the start button to acquire data.
How does the photometric repeatability of the SpectraCore UV 3102 vary with absorbance range, and what are the implications for quantitative analysis of high-concentration samples?
The SpectraCore UV 3102 specifies photometric repeatability of ±0.001 A from 0 to 0.5 A and ±0.0015 A from 0.5 to 1 A. This 50% increase in uncertainty at higher absorbance levels means that measurements near 1 A are less precise, which should be accounted for when quantifying concentrated samples that push absorbance into the upper end of the photometric range.
Does the SpectraCore UV 3102 support long-pathlength cuvettes for trace analysis, and what accessories are required for compatibility?
The standard configuration includes a 4-position cell holder for 10 mm pathlength cells. An optional fixed long-cell holder is available for extended pathlengths, but the product description does not specify the maximum pathlength or reference codes. Contact the manufacturer to confirm compatibility with your specific cuvette dimensions and to order the appropriate holder.
What are the electrical power requirements for the SpectraCore UV 3102, and does it require a voltage selector or dedicated circuit?
The SpectraCore UV 3102 operates on 110/220 V, 50/60 Hz, with a power consumption of 120 W. The product description does not indicate whether the power supply is auto-ranging or requires manual voltage selection, so verify the voltage configuration with the manufacturer before installation to ensure proper integration into your laboratory's electrical infrastructure.
The SpectraCore UV 3102 is a double-beam UV-Vis spectrophotometer with a fixed 2.0 nm bandwidth covering 190-1100 nm, offering ±0.3 nm wavelength accuracy and ≤0.001 A/h stability for routine absorbance and transmittance measurements. Its deuterium lamp requires periodic replacement, and the fixed bandwidth limits resolution for high-precision spectral analysis.
Positive
- Double beam optical system for stable measurements: The double beam design compensates for source fluctuations and environmental drift, enabling reliable long-term absorbance and transmittance measurements without frequent baseline correction.
- High wavelength accuracy and stability: Wavelength accuracy of ±0.1 nm at 656.1 nm and ±0.3 nm full range, combined with photometric stability ≤0.001 A/h at 500 nm, ensures reproducible quantitative analysis.
Trade-offs
- Deuterium lamp requires periodic replacement: The deuterium lamp used for UV measurements has a finite operational lifetime; routine replacement is necessary to maintain UV performance, and the user must plan for consumable costs and downtime.
- Fixed 2.0 nm bandwidth limits resolution flexibility: The instrument has a fixed spectral bandwidth of 2.0 nm, which may not be suitable for applications requiring narrower bandpass for fine spectral detail or for methods that demand variable slit widths.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.