Anti-Oxidation Nitrogen Cabinet 730 L ESD ATOMFAIR®

$1,950.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

730 L anti-oxidation nitrogen cabinet with anti-static body, 1%-60% RH control, 0-50 L/min N2 flow, 5 shelves, and Honeywell sensing. Order now.

SKU: AF-EI-E-AONC-ESD0-730L
Category:
Tags:
Brands:

730L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 730 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 600 × 690 × 1830 mm, inner dimensions of 555 × 640 × 1660 mm and 5 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC730F
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 730 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 600 × 690 × 1830 mm
Inner Dimensions (W × D × H) 555 × 640 × 1660 mm
Adjustable Shelf Quantity 5
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 5 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires a stable indoor surface, a clean nitrogen supply, and proper sealing to maintain a controlled low-humidity atmosphere for oxidation-sensitive materials. The anti-static cabinet body and tempered-glass doors impose electrostatic discharge and structural integrity constraints during handling and storage.

  • Environmental Installation: Install the cabinet on a stable indoor surface and ensure the door seals properly before operation.
  • Nitrogen Supply: Verify stable gas-supply conditions with a flow rate of 0-50 L/min before operation to maintain the required humidity range.
  • Load Distribution: Distribute stored items evenly across the five adjustable shelves to avoid overloading and maintain internal circulation.
  • ESD Compatibility: Use the anti-static cabinet body for electrostatic-sensitive materials to prevent damage from static discharge.
  • Sensor Accuracy: Account for the annual sensor drift of 0.3% when monitoring humidity; recalibrate as needed for critical applications.

Follow these steps to install the cabinet, connect utilities, and load materials for safe and effective dry storage. Proper setup ensures the cabinet maintains the required low-humidity nitrogen atmosphere for oxidation-sensitive materials.

Required Equipment: Nitrogen gas supply line with adjustable flow regulator, Electrical power connection (standard outlet), Spirit level for verifying cabinet levelness, Anti-static gloves for handling ESD-sensitive materials

  1. Inspect and Verify
    Inspect the cabinet after delivery for any damage and verify that the door seals are intact.
  2. Position and Level
    Place the cabinet on a stable indoor surface and use a spirit level to ensure it is level.
  3. Connect Nitrogen Supply
    Connect the nitrogen gas supply to the cabinet's inlet and set the flow rate between 0 and 50 L/min.
  4. Connect Power
    Plug the cabinet into a standard electrical outlet and turn on the power to activate the automatic control.
  5. Configure Humidity Control
    Set the desired humidity control range using the computer control panel, typically between 1% and 60% RH.
  6. Load Materials
    Distribute stored materials evenly across the five adjustable shelves, ensuring they do not exceed the shelf load limit.
  7. Monitor and Maintain
    Keep the door closed during normal operation and monitor the temperature and humidity display for any deviation.

How does the anti-static cabinet body compare to the optional stainless steel upgrade for ESD-sensitive material storage?

The standard anti-static cabinet body uses a 1.2 mm galvanized steel cabinet with an anti-static exterior coating, providing electrostatic discharge (ESD) protection suitable for ESD-sensitive material handling. The optional stainless steel cabinet-body upgrade offers superior corrosion resistance and a cleaner storage environment, but it does not inherently provide ESD protection. The choice depends on whether ESD control or corrosion resistance is the higher priority for your stored oxidation-sensitive and moisture-sensitive materials.

Can this 730L nitrogen cabinet be integrated with an on-site nitrogen generator or external monitoring system?

Yes, the cabinet supports an optional nitrogen generator configuration for on-site nitrogen supply. Additionally, an optional RS485 communication interface is available for PC-side monitoring and recorded cabinet-status management. These options allow the cabinet to be integrated into a broader nitrogen infrastructure and digital monitoring system for controlled atmosphere storage.

What are the infrastructure and handling requirements for installing this 730L anti-oxidation nitrogen cabinet?

The cabinet must be installed on a stable indoor surface with verified power and nitrogen gas connections. During normal use, the door should remain closed, stored items should be distributed evenly across the five adjustable shelves, and the cabinet should not be subjected to loads or conditions beyond its specifications. Before operation, stable gas-supply conditions must be confirmed. During movement, protect structural and sealing components, and use reinforced wooden-crate packaging for shipment.

This 730L anti-oxidation nitrogen cabinet with anti-static body, five adjustable shelves, and Honeywell sensor provides controlled low-humidity storage for ESD-sensitive materials, but requires stable nitrogen supply and cannot achieve humidity below 1% RH.

Positive

  • Anti-static cabinet for ESD protection: The anti-static exterior coating and cabinet body are explicitly designed for electrostatic-control areas, making it suitable for handling ESD-sensitive materials without additional grounding mats.
  • High-accuracy Honeywell sensor with low drift: The Honeywell temperature and humidity sensor provides ±3% RH accuracy and 0.3% annual drift, ensuring reliable monitoring for long-term storage of sensitive materials.

Trade-offs

  • Requires stable nitrogen supply: Operation depends on a stable gas supply and proper utility connections (power and gas), which must be verified before use to maintain controlled atmosphere conditions.
  • Humidity cannot go below 1% RH: The humidity control range is limited to 1%-60% RH, so it cannot achieve sub-1% RH levels that may be needed for extremely moisture-sensitive applications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).