Anti-Oxidation Nitrogen Cabinet 160 L ESD ATOMFAIR®

$1,050.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

160 L anti-oxidation nitrogen cabinet with anti-static body, 1%-60% RH control, 450 × 450 × 1010 mm size, Honeywell sensor and 3 shelves. Order now.

SKU: AF-EI-E-AONC-ESD0-160L
Category:
Tags:
Brands:

160L Anti-Oxidation Nitrogen Cabinet, Anti-Static Cabinet Body

Research-grade laboratory product

Product Overview

The 160 L configuration uses a anti-static cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 450 × 450 × 1010 mm, inner dimensions of 405 × 420 × 840 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type is suitable for electrostatic-control areas and ESD-sensitive material handling.

The cabinet combines 1.2 mm galvanized steel cabinet with anti-static exterior coating, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC160F
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Anti-static cabinet body
Nominal Capacity 160 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 450 × 450 × 1010 mm
Inner Dimensions (W × D × H) 405 × 420 × 840 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with anti-static exterior coating and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet requires a stable indoor surface, a continuous nitrogen supply (0-50 L/min), and power connection for automatic control. Proper sealing of the magnetic door and even distribution of stored materials are necessary to maintain the specified humidity range and prevent damage.

  • Stable Installation: Position the cabinet on a level, stable surface to ensure door alignment and sealing integrity.
  • Nitrogen Supply: Verify a stable nitrogen supply with flow adjustment between 0 and 50 L/min before operation.
  • Even Loading: Distribute stored items evenly across the three adjustable shelves to avoid exceeding the shelf-load capacity.
  • Door Sealing: Keep the cabinet door closed during normal use and inspect the magnetic seal regularly for airtightness.
  • Utility Conditions: Confirm power and gas connections are correctly configured before formal use of the cabinet.

Follow these steps to install, configure, and begin using the nitrogen cabinet for controlled storage of oxidation-sensitive materials. Proper setup ensures accurate humidity control and extends the lifespan of stored items.

  1. Position the cabinet
    Position the cabinet on a stable level surface near a nitrogen supply source and power outlet.
  2. Connect nitrogen supply
    Connect the nitrogen supply line to the cabinet's flow control inlet and set the flow rate between 0 and 50 L/min.
  3. Power on the cabinet
    Plug the cabinet into a suitable power source and turn on the automatic control system.
  4. Verify system status
    Verify that the temperature and humidity display shows readings within the expected range and the door seals properly.
  5. Load materials
    Load oxidation-sensitive materials evenly onto the adjustable shelves, ensuring the door can close fully.

What is the practical impact of the ±3% RH humidity indication accuracy on maintaining ultra-low humidity conditions near 1% RH for oxidation-sensitive materials?

At a 1% RH setpoint, the ±3% RH accuracy means the actual chamber humidity could range from 0% to 4% RH. This tolerance is acceptable for general oxidation-sensitive storage, but applications requiring tighter control (e.g., below 2% RH) may benefit from the optional electronic dehumidification module to reduce reliance on nitrogen purge alone.

Can the over-humidity alarm be integrated with external building management systems or is it limited to local alerts?

The standard over-humidity alarm provides local indication only. For remote monitoring or integration with external management systems, the optional RS485 communication interface is required, which enables PC-side status logging and alarm notification. The product description does not specify the alarm's electrical output type, so direct BMS integration may require additional adaptation.

What nitrogen supply specifications are needed to reliably achieve the full 0-50 L/min flow adjustment range?

The product description does not specify required nitrogen purity or supply pressure. For reliable operation up to 50 L/min, a clean, dry nitrogen source with a pressure regulator capable of maintaining stable flow is necessary. Users should verify supply compatibility with the manufacturer, as inadequate pressure or impurities may compromise humidity control and cabinet atmosphere stability.

This 160L anti-oxidation nitrogen cabinet with anti-static body provides a controlled low-humidity nitrogen atmosphere for oxidation- and moisture-sensitive materials, featuring Honeywell sensor accuracy and adjustable nitrogen flow, but requires external nitrogen supply and careful environmental planning.

Positive

  • Precision humidity sensing with low drift: Honeywell temperature and humidity sensor provides ±3% RH indication accuracy and only 0.3% annual drift, ensuring reliable long-term humidity control for stored materials.
  • Adjustable nitrogen flow for atmosphere control: 0-50 L/min nitrogen flow adjustment combined with fully automatic computer control allows precise management of cabinet atmosphere, reducing oxidation and moisture absorption.

Trade-offs

  • Requires external nitrogen supply: Operation depends on a stable external nitrogen gas supply; users must verify gas-supply conditions before use, adding infrastructure and ongoing consumable costs.
  • Standard body not corrosion-resistant: The standard anti-static coating on galvanized steel may not be suitable for corrosive environments; a stainless steel upgrade is optional and requires additional procurement.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).