Anti-Oxidation Nitrogen Cabinet 98L 1%-60% RH ATOMFAIR®

$950.00

Heavy Item Pricing: Prices for this heavy item are net prices (ex-factory / ex-warehouse) and exclude logistics or shipping fees.

Heavy Item Shipping: The final shipping cost will be calculated based on the product’s physical characteristics, including weight and volume, the selected transport mode, such as land, air, or sea freight, and the actual shipping distance. We arrange shipment from the nearest available global warehouse based on your delivery address, current stock levels, and logistical arrangements.

Due to fluctuations in global oil prices and market dynamics, please contact inquiry@atomfair.com to obtain an accurate real-time shipping quote and your order total before placing your order.

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

98 L anti-oxidation nitrogen cabinet with 1%-60% RH control, 448 × 400 × 688 mm body, Honeywell sensing, 0-50 L/min N2 flow and 3 shelves. Order now.

SKU: AF-EI-E-AONC-STD0-098L
Category:
Brands:

98L Anti-Oxidation Nitrogen Cabinet

Research-grade laboratory product

Product Overview

The 98 L configuration uses a standard white cabinet body, a humidity control range of 1%-60% RH, outer dimensions of 448 × 400 × 688 mm, inner dimensions of 446 × 372 × 598 mm and 3 adjustable shelves.

This anti-oxidation nitrogen cabinet is designed for oxidation-sensitive and moisture-sensitive materials that benefit from a controlled low-humidity nitrogen atmosphere. It helps reduce moisture absorption, oxidation, optical haze, solderability loss and storage instability during inspection staging, daily handling and long-term preservation.

Typical application areas include research laboratories, electronics workshops, optical part storage rooms, powder and film storage areas, technical archives and quality-control spaces that require organized nitrogen-assisted dry storage. This body type suits general laboratories, inspection rooms and organized storage areas.

The cabinet combines 1.2 mm galvanized steel cabinet with white exterior panels, tempered-glass viewing doors and magnetic sealing, Honeywell temperature and humidity sensing, fully automatic computer control, temperature and humidity display, perforated adjustable shelves and 0-50 L/min nitrogen-flow adjustment for repeatable daily operation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-AONC98
Product Family Anti-Oxidation Nitrogen Cabinet
Cabinet Body Standard white cabinet body
Nominal Capacity 98 L
Humidity Control Range 1%-60% RH
Outer Dimensions (W × D × H) 448 × 400 × 688 mm
Inner Dimensions (W × D × H) 446 × 372 × 598 mm
Adjustable Shelf Quantity 3
Cabinet Material 1.2 mm galvanized steel cabinet with white exterior panels and 5 mm tempered-glass viewing doors
Control Mode Fully automatic computer control
Display and Monitoring Display-based monitoring for temperature, humidity and operating status
Temperature Display Range -9°C to 99°C
Humidity Display Range 0%-99% RH
Humidity Indication Accuracy ±3% RH
Annual Sensor Drift 0.3%
Sensor Honeywell temperature and humidity sensor
Nitrogen Flow Control 0-50 L/min
Alarm Function Over-humidity alarm support
Suitable Stored Materials Oxidation-sensitive electronic components, optical parts, powders, films and laboratory materials

Key Features and Advantages

  • 1.2 mm galvanized steel cabinet construction with 5 mm tempered-glass viewing panels, magnetic door sealing and a lockable cabinet structure.
  • Honeywell temperature and humidity sensor with ±3% RH humidity indication accuracy and 0.3% annual drift.
  • Fully automatic computer control with temperature display range of -9°C to 99°C and humidity display range of 0%-99% RH.
  • Perforated adjustable shelves support orderly material staging and internal circulation.
  • Nitrogen-control arrangement with 0-50 L/min flow adjustment for controlled cabinet-atmosphere management.

Optional Items and Consultation

  • Anti-static cabinet body upgrade with ESD-compliant exterior coating for electrostatic-control environments.
  • Internal high-brightness LED lighting for improved visibility in cabinet interiors.
  • Stainless steel cabinet-body upgrade for cleaner or more corrosion-conscious storage environments.
  • Electronic dehumidification module that can operate together with the gas-filling unit to reduce nitrogen use.
  • Nitrogen generator configuration for applications that prefer an on-site nitrogen supply.
  • RS485 communication interface for PC-side monitoring and recorded cabinet-status management.
  • Over-humidity alarm device that triggers when measured humidity exceeds the configured set value.
  • If optional items are required, please contact inquiry@atomfair.com.
APPLICATION SCOPE: Suitable for research laboratories, electronics workshops, optical storage rooms, powder and film storage areas, technical archives and quality-control environments that require controlled nitrogen-assisted dry storage for oxidation-sensitive and moisture-sensitive materials.
HANDLING & STORAGE: Install the cabinet on a stable indoor surface, keep the door closed during normal use, distribute stored items evenly across the 3 shelf levels, protect structural and sealing components during movement, and use reinforced wooden-crate packaging when shipment protection is required. Verify stable gas-supply conditions before operation.
IMPORTANT NOTICE: Confirm the correct model, cabinet body type, capacity and optional accessories before ordering. Inspect the cabinet after delivery, verify level installation and door sealing, and do not exceed the stated shelf-loading or application conditions. Confirm utility conditions such as power and gas connections before formal use.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, configuration review, accessory matching or application-specific guidance, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The cabinet maintains a controlled low-humidity nitrogen atmosphere for oxidation- and moisture-sensitive materials. Proper operation requires stable gas supply, level installation, and routine monitoring of humidity and temperature.

  • Installation Surface Requirement: The cabinet must be placed on a stable indoor surface to prevent door misalignment and seal failure.
  • Door Sealing Integrity: Magnetic door sealing must remain intact and free of debris to maintain the controlled atmosphere.
  • Nitrogen Flow Adjustment: Nitrogen flow must be adjusted between 0 and 50 L/min to achieve and sustain the desired humidity level.
  • Humidity Sensor Accuracy: The Honeywell sensor provides ±3% RH accuracy with an annual drift of 0.3%, requiring periodic verification.
  • Shelf Load Distribution: Stored items must be evenly distributed across the three adjustable shelves to ensure uniform gas circulation.

Initial setup involves placing the cabinet on a stable surface and connecting a regulated nitrogen supply. After verifying sensor readings, adjust the flow rate to maintain the desired humidity setpoint.

  1. Position the Cabinet
    Install the cabinet on a level indoor surface and verify that it is stable and the door seals properly.
  2. Connect Nitrogen Supply
    Connect a regulated nitrogen source to the cabinet inlet, then set the flow rate between 0 and 50 L/min using the control knob.
  3. Set Humidity Setpoint
    Use the automatic computer control interface to set the desired humidity setpoint within the 1%–60% RH range.
  4. Arrange Stored Materials
    Distribute items evenly across the three adjustable shelves to promote uniform gas circulation and prevent overloading.
  5. Monitor and Adjust
    Close the door and monitor the display for temperature and humidity; if the humidity exceeds the setpoint, check the sealing and nitrogen flow.

What is the practical impact of the ±3% RH sensor accuracy on the low-humidity storage capability of the 98L Anti-Oxidation Nitrogen Cabinet for materials requiring <5% RH?

The Honeywell sensor has ±3% RH accuracy, so at a set point of 5% RH the actual cabinet humidity may range from 2% to 8% RH. This is suitable for many oxidation-sensitive materials, but for those requiring strict control below 5% RH the variance may be a limitation. The cabinet's humidity control range is 1%–60% RH, and the sensor's 0.3% annual drift supports long-term stability.

Can the 98L Anti-Oxidation Nitrogen Cabinet be used with a central nitrogen supply system, or does it require a dedicated nitrogen generator?

The cabinet accepts nitrogen via a 0–50 L/min flow adjustment valve and can be connected to a central nitrogen supply if the pressure and flow are compatible. An optional nitrogen generator is also available for on-site generation. Additionally, an optional RS485 interface enables integration with a PC monitoring system for centralized control.

What are the critical installation steps and safety considerations for operating the 98L Anti-Oxidation Nitrogen Cabinet with compressed nitrogen?

The cabinet must be placed on a stable indoor surface, with power and gas connections verified before use. Stored items should be evenly distributed on the three adjustable shelves. Nitrogen is an asphyxiant, so adequate ventilation is required. The cabinet has a magnetic door seal to minimize leakage, and an over-humidity alarm can be configured. For shipment, use reinforced wooden crate packaging.

The 98L Anti-Oxidation Nitrogen Cabinet uses a Honeywell sensor with ±3% RH accuracy and automatic 0-50 L/min nitrogen flow control for precise atmosphere management, but requires external nitrogen and power infrastructure and is limited to a minimum humidity of 1% RH.

Positive

  • Honeywell sensor with ±3% RH accuracy: The Honeywell temperature and humidity sensor provides ±3% RH indication accuracy and 0.3% annual drift, enabling reliable long-term humidity monitoring in the nitrogen cabinet.
  • Automatic nitrogen flow control 0-50 L/min: Fully automatic computer control with 0-50 L/min nitrogen flow adjustment allows repeatable, controlled cabinet-atmosphere management for oxidation-sensitive materials.

Trade-offs

  • Requires external nitrogen supply and power: The cabinet depends on a stable external nitrogen gas supply and power connection for operation, which must be verified before use and adds infrastructure requirements.
  • Humidity limited to 1%-60% RH range: The humidity control range is specified as 1%-60% RH, meaning the cabinet cannot achieve ultra-low humidity levels below 1% RH, which may be a constraint for certain moisture-sensitive materials.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).