Fixed-Volume Mini Pipette 50 μL ISO 8655-2 ATOMFAIR®

$2.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fixed-volume single-channel mini pipette for 50 μL transfers, with ±0.25 μL systematic error, ±0.15 μL random error and ISO 8655-2 calibration reference.

SKU: AF-EI-L-MINP-K050-SC00
Category: ,
Tags:
Brands:

Description

Mini Pipette Single-channel 50 µL Pipette

Product Type: Fixed-volume mini pipette
Research-grade liquid handling platform

Product Overview

Mini Pipette Single-channel 50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 50 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 50 µL working range, Fixed volume increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 50 µL with Fixed volume increment.
  • Sterilization suitability: Not suitable for high-temperature sterilization.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MINI-PIPETTE-50-µL
Product Family Mini Pipette
Channel count Single-channel
Volume range 50 µL
Increment Fixed volume
Test volume(s) 50 µL
Systematic error At 50 µL: ±0.25 µL (±0.5%)
Random error At 50 µL: ±0.15 µL (±0.3%)
Sterilization suitability Not suitable for high-temperature sterilization
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Fixed-volume pipette technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette is not suitable for high-temperature sterilization and requires calibration per ISO 8655-2 to maintain specified accuracy. Use only compatible tips to ensure proper sealing and volume delivery.

  • Sterilization Limitation: The pipette cannot be sterilized by autoclaving and must be cleaned using low-temperature methods.
  • Calibration Requirement: User calibration must be performed against ISO 8655-2 reference to verify systematic error within ±0.25 µL and random error within ±0.15 µL at the 50 µL test volume.
  • Tip Compatibility: Only tips specifically designed for this pipette model should be used to avoid leakage and inaccurate volume transfer.
  • Fixed-Volume Constraint: The pipette delivers a fixed 50 µL volume and cannot be adjusted for other volumes.

How does the fixed volume of 50 µL on the Atomfair Mini Pipette affect its accuracy and precision compared to adjustable pipettes?

The fixed volume eliminates user adjustment variability, delivering consistent systematic error of ±0.25 µL (±0.5%) and random error of ±0.15 µL (±0.3%) at 50 µL as per ISO 8655-2. This ensures high repeatability for single-volume tasks like PCR setup, but the pipette cannot be adjusted for other volumes, unlike adjustable models.

Can the Atomfair Mini Pipette 50 µL be autoclaved for sterilization between uses?

No, the product specification states it is not suitable for high-temperature sterilization. Alternative sterilization methods such as chemical disinfection or UV exposure must be used for aseptic applications.

What calibration standard is used for the Atomfair Mini Pipette 50 µL and what is the recommended calibration interval?

The pipette is calibrated per ISO 8655-2, as indicated in the technical specifications. The product description does not specify a calibration interval; laboratories should follow their own standard operating procedures based on usage frequency and quality assurance requirements.

The Atomfair Mini Pipette Single-channel 50 µL offers fixed-volume dispensing with verified accuracy (±0.5% systematic error) and precision (±0.3% random error) at 50 µL, making it suitable for PCR setup and routine liquid handling. However, it is not autoclavable and is limited to a single fixed volume.

Positive

  • Accurate fixed-volume dispensing: Systematic error at 50 µL is ±0.25 µL (±0.5%) and random error is ±0.15 µL (±0.3%), ensuring reliable liquid transfer for routine analytical workflows.
  • Suitable for PCR setup: The 50 µL fixed volume is well-suited for single-tube sample preparation, reagent addition, and PCR or qPCR setup.

Trade-offs

  • Not autoclavable: The pipette is not suitable for high-temperature sterilization, requiring alternative sterilization methods or single-use tips for aseptic applications.
  • Fixed volume limitation: The 50 µL volume is fixed with no adjustment capability, restricting its use to applications requiring exactly 50 µL transfers.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).