Description
Mini Pipette Single-channel 25 µL PipetteProduct Type: Fixed-volume mini pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This document outlines technical constraints and handling requirements for the fixed-volume 25 µL mini pipette. Compliance with calibration reference and sterilization limitations is essential for maintaining measurement accuracy and device integrity.
- Calibration Compliance: The pipette must be calibrated according to ISO 8655-2 with systematic error not exceeding ±0.125 µL and random error not exceeding ±0.075 µL at 25 µL test volume.
- Sterilization Incompatibility: The pipette is not suitable for high-temperature sterilization; alternative sterilization methods must be evaluated if required.
- Tip Compatibility: Only compatible pipette tips should be used to ensure stable tip fit and accurate volume delivery.
- Volume Increment: The pipette has a fixed volume increment of 25 µL, limiting use to single-volume applications without adjustment.
How do the systematic and random error specifications at 25 µL (±0.5% and ±0.3%) impact the reliability of quantitative PCR setup?
The fixed 25 µL volume delivers a systematic error of ±0.125 µL (±0.5%) and a random error of ±0.075 µL (±0.3%) at the test volume, as specified in the technical table. These tolerances ensure reproducible dispensing for PCR and qPCR workflows where volume consistency directly affects reaction efficiency and Ct values. Routine calibration per ISO 8655-2 is required to maintain this performance over time.
What calibration infrastructure is required to maintain ISO 8655-2 compliance for the Atomfair 25 µL fixed-volume pipette?
The pipette includes a user calibration reference indicated in the technical table per ISO 8655-2, meaning users must follow gravimetric calibration procedures with a calibrated balance and controlled environmental conditions appropriate for 25 µL. No internal factory adjustment is described, so in-lab calibration planning and periodic verification are needed to maintain traceable accuracy. The fixed-volume design simplifies calibration because only one test volume (25 µL) must be checked.
Can the Atomfair 25 µL mini pipette be sterilized by autoclaving, and what are the alternative decontamination methods?
No, this pipette is explicitly marked as not suitable for high-temperature sterilization. Therefore autoclaving or dry-heat sterilization is not recommended. Alternative decontamination methods such as chemical disinfection (e.g., 70% ethanol or proprietary pipette decontamination solutions) should be used, following the manufacturer's guidance for materials compatibility.
This fixed-volume 25 µL single-channel mini pipette delivers acceptable accuracy and precision for routine liquid handling but is not autoclavable, restricting sterilization options, and its fixed volume limits flexibility.
Positive
- Accurate fixed-volume liquid handling: Systematic error of ±0.5% and random error of ±0.3% at 25 µL ensures reliable and reproducible liquid transfer for routine assays.
- Single-channel for routine workflows: The single-channel format is ideal for single-tube sample preparation, serial dilution, and PCR setup, simplifying process integration.
Trade-offs
- Not autoclavable: The pipette is not suitable for high-temperature sterilization, requiring alternative low-temperature disinfection methods, which may limit use in aseptic workflows.
- Fixed volume inflexibility: The 25 µL fixed volume increment prevents volume adjustment, necessitating separate pipettes for different volumes.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).