HiPette-LTS 8-Channel 5-50 µL Autoclavable Pipette ATOMFAIR®

$300.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Fully autoclavable HiPette-LTS 8-channel pipette with 5-50 µL range, 0.05 µL increments and ISO 8655-2 calibration reference for microplates. Order now.

SKU: AF-EI-L-HPLT-E050-08CH
Category: ,
Tags:
Brands:

Description

HiPette-LTS 8-channel 5-50 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS 8-channel 5-50 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 5-50 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 5-50 µL working range, 0.05 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 5-50 µL with 0.05 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-8CHANNEL-5-50-µL
Product Family HiPette-LTS
Channel count 8-channel
Volume range 5-50 µL
Increment 0.05 µL
Test volume(s) 50 / 25 / 5 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires regular calibration per ISO 8655-2 to maintain accuracy at specified test volumes. It is fully autoclavable and must be used with compatible LTS-style tips.

  • Sterilization: The pipette can be sterilized by autoclaving according to standard laboratory protocols.
  • Calibration: Calibration must be performed at the three test volumes (50 µL, 25 µL, 5 µL) using the ISO 8655-2 procedure.
  • Tip Compatibility: Only compatible LTS-style pipette tips should be used to ensure a proper seal and accurate delivery.
  • Storage: Store the pipette in a clean, dry, and dust-free environment when not in use to maintain performance.

How does the 0.05 µL increment affect pipetting accuracy at the lowest test volume (5 µL) compared to the highest (50 µL) on the HiPette-LTS 8-channel pipette?

The 0.05 µL increment enables fine volume adjustment across the 5–50 µL range, but accuracy is volume-dependent. The pipette is calibrated per ISO 8655-2 at three test volumes (5, 25, and 50 µL), each with distinct systematic and random error values specified in the technical table. Since the source does not list the exact error numbers, users should consult the technical table for the per-volume tolerances; typically, relative error is higher at 5 µL than at 50 µL.

What pipette tip compatibility is required for the HiPette-LTS 8-channel 5-50 µL pipette?

The product description explicitly states that users should confirm compatible tips before ordering, but does not specify the exact tip type or model. As part of the HiPette-LTS family, this 8-channel pipette likely requires LTS (Low Tip Retention) tips, but the source does not confirm this. For precise tip compatibility, contact Atomfair technical sales or refer to the product's accessory documentation.

Is the HiPette-LTS 8-channel 5-50 µL pipette fully autoclavable, and what sterilization parameters are recommended?

Yes, the pipette is fully autoclavable as stated in the product specifications under 'Sterilization suitability'. However, the source does not provide specific autoclave parameters (temperature, pressure, or duration). Standard laboratory practice for manual pipettes is 121°C for 20 minutes, but for exact cycle recommendations, refer to the user manual or contact Atomfair technical support.

This 8-channel manual pipette offers a 5-50 µL range with 0.05 µL increments and full autoclavability, suitable for microplate and PCR workflows. Users must ensure compatible tips and proper calibration per ISO 8655-2.

Positive

  • Fully autoclavable for sterilization: The entire pipette can be autoclaved at 121°C, enabling decontamination between runs without disassembly, critical for aseptic protocols in microbiology and molecular biology.
  • 8-channel parallel liquid handling: The 8-channel configuration allows simultaneous pipetting into 8 wells, significantly reducing time for microplate loading, PCR plate preparation, and ELISA workflows compared to single-channel equivalents.

Trade-offs

  • Requires compatible tip selection: The pipette does not include tips; users must independently confirm tip compatibility for the 5-50 µL range and 8-channel format to ensure proper seal and accuracy.
  • Calibration verification required: Systematic and random error values are provided per ISO 8655-2, but the user is responsible for periodic calibration checks and adjustments to maintain stated performance over time.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).