Vacuum Drying Oven 25L Explosion-Proof SUS304 ATOMFAIR®

$1,199.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

SUS304 stainless steel chamber vacuum drying oven, 25L capacity, 250°C max temperature, vacuum ≤133Pa. Explosion-proof glass door. Order now.

SKU: AFMSASDP427
Category:
Brands:

Description

ATOMFAIR® VACUUM DRYING OVEN MODEL ATOMFAIR-VDO856

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® Vacuum Drying Oven (Model: Atomfair-VDO856) is a precision-engineered laboratory instrument optimized for high-performance thermal sample desiccation, chemical sterilization, and controlled atmospheric heat treatment profiles. Serving as a robust 25L Laboratory Sterilizer chamber, this system provides absolute environmental confinement to safely treat moisture-sensitive compounds, polymers, and advanced electronic components under intense vacuum depths. It incorporates a heavy-duty structural envelope paired with a dual-layer explosion-proof observation door, granting researchers an unobstructed, secure sightline into active vacuum test runs. Built for extensive durability, this compact system ensures minimal temperature drift and exceptional structural sealing for demanding academic and corporate R&D laboratories.

Technical Specifications

PARAMETER DETAILS
Product Model Atomfair-VDO856 (Version V2.0)
Internal Capacity 25 L Optimized Rectangular Chamber
Temperature Range RT + 10 ~ 250 °C Nominal Range
Temperature Uniformity ± 1.0 °C Spatial Variance Boundary
Temperature Resolution 0.1 °C Digital Resolution
Ultimate Vacuum Degree ≤ 133 Pa (-0.1 MPa Relative Negative Pressure Boundary)
Inner Chamber Metallurgy SUS304 Corrosion-Resistant Stainless Steel
Exterior Surface Coating High-Temperature Electrostatic Powder Coating Protective Armor
Chassis Sealing Gasket Integrated Molded High-Temperature Silicone Seals
Electrical Power Standard 1.4 kW Maximum Rating
Voltage & Frequency Requirements Single-Phase AC 220V / 50 Hz Nominal Input
External Dimensions (L × W × H) 430 × 320 × 340 mm
Equipment Net Weight 50 kg
Alternative Options Explore our related catalog or custom dimensions. For urgent technical custom requests or bulk inquiries, please contact our support team.

Key Features & Advantages

  • Volumetric Spatial Optimization: Features a specialized rectangular internal geometry that maximizes effective tray space, allowing dense multi-sample loading compared to traditional cylindrical cavities.
  • Dual-Layer Tempered Containment: Equipped with a heavy-duty dual-pane tempered safety glass window assembly, keeping active experimental observation safe without compromising thermal isolation.
  • Adjustable Hermetic Door Tension: Features an elastic structural door latch link paired with an integrated high-temperature silicone gasket to maintain reliable airtight performance.
  • SUS304 Structural Metallurgy: Constructed with a premium grade stainless steel core shell protected by an exterior high-temperature electrostatic powder jacket, providing excellent protection against wear.

APPLICATION SCOPE: Crafted specifically for industrial and mining laboratories, university material processing, oxygen-free sample baking, moisture testing, and medical grade tool serialization scripts.
PACKAGING: Encased in an export-grade 430 × 320 × 340 mm structural outer container packed with molded corner shock buffers to preserve calibration values during international transport.
IMPORTANT NOTICE: Never venture over the absolute maximum 250 °C operating boundary threshold. Ensure the high-temperature silicone seal path is thoroughly inspected for debris before drawing down the ultimate ≤ 133 Pa negative pressure system.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This oven operates at high temperatures and under vacuum, requiring strict thermal and pressure management. Electrical safety grounding and adequate ventilation are necessary to mitigate fire or explosion hazards.

  • Thermal Safety: Allow the oven to cool below 50°C before opening the door to prevent thermal shock and burns.
  • Vacuum Integrity: Do not exceed the maximum rated vacuum degree to avoid structural stress on the chamber and door seal.
  • Electrical Hazard: Connect the oven only to a grounded power outlet matching the rated voltage and current to prevent electrical shock.
  • Material Compatibility: Use only materials that are stable under vacuum and at the set temperature to avoid decomposition or off-gassing.
  • Ventilation Requirement: Place the oven in a well-ventilated area to dissipate heat and any potential fumes from the process.

Set up the oven on a stable, level surface and connect it to a grounded power source. Follow sequential steps to load samples, apply vacuum, heat, and cool before retrieval.

Required Equipment: Vacuum pump with compatible hose and fittings, Heat-resistant gloves and safety goggles

  1. Prepare Workspace
    Position the oven on a stable, non-flammable surface and ensure the area is well-ventilated.
  2. Connect Power
    Verify the power cord is inserted into a grounded outlet matching the required voltage and power rating.
  3. Set Temperature
    Turn on the oven and use the digital controller to set the desired operating temperature.
  4. Load Samples
    Place the samples inside the chamber, ensuring they are arranged for uniform heat and vacuum exposure.
  5. Seal Chamber
    Close the door securely and tighten the handle to achieve an airtight seal using the silicone gasket.
  6. Apply Vacuum
    Connect the vacuum pump to the oven port and activate it until the chamber reaches the desired vacuum level.
  7. Finalize Process
    After the treatment cycle ends, turn off heating, slowly release the vacuum, allow the chamber to cool, then open the door.

At what vacuum level can the Atomfair-VDO856 achieve its specified temperature uniformity of ±1.0°C?

The Atomfair-VDO856 achieves ±1.0°C temperature uniformity across its 25L chamber when operating at a vacuum of ≤133Pa (-0.1MPa), as specified in the technical specifications. This ensures consistent heat distribution during vacuum drying processes.

What is the minimum achievable temperature in the Atomfair-VDO856, and is it suitable for drying heat-sensitive materials?

The oven's temperature range is RT+10 to 250°C, meaning the minimum setpoint is 10°C above ambient room temperature. It is not suitable for heat-sensitive materials that require drying below ambient temperature; for such applications, a refrigerated vacuum oven would be necessary.

What are the electrical requirements for installing the Atomfair-VDO856?

The Atomfair-VDO856 requires a 220V/50Hz single-phase power supply with a power consumption of 1.4kW. Ensure the electrical outlet matches these specifications and that the circuit is capable of handling the load, as the oven is designed for 50Hz operation only.

The Atomfair-VDO856 25L Vacuum Drying Oven offers a rectangular SUS304 chamber and explosion-proof glass door for safe observation, but its moderate vacuum level and elevated minimum temperature constrain its use to general drying and sterilization tasks at moderate vacuum.

Positive

  • Rectangular chamber maximizes usable space: The rectangular design of the working chamber increases effective internal volume compared to cylindrical vacuum ovens, allowing more efficient sample placement and batch processing.
  • Explosion-proof glass with stainless steel chamber: Double-layer tempered explosion-proof glass door enables safe visual monitoring of samples, while the SUS304 stainless steel interior resists corrosion and facilitates cleaning.

Trade-offs

  • Moderate ultimate vacuum: With a specified vacuum degree of ≤133 Pa, this oven is not suitable for high-vacuum applications such as electron microscopy sample preparation or advanced thin-film deposition.
  • Limited low-temperature range: The minimum operating temperature of RT+10°C precludes use for vacuum drying of heat-sensitive materials that require temperatures near or below ambient.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).