Electronic Pipette 20-200μL Autoclavable 5 Modes ATOMFAIR®

$1,493.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 20-200μL electronic pipette with ±0.8% accuracy & 0.2μL increment. Autoclavable at 121°C. Five operating modes. Order now.

SKU: AFMSVDVK890
Category:
Tags:
Brands:

Description

ATOMFAIR® ATOMFAIR-PIP284 ELECTRONIC PIPETTE

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® Atomfair-PIP284 Electronic Pipette is an elite, micro-volumetric fluid management instrument engineered for exceptional dispensing accuracy across biological and clinical workflows. Serving as a highly responsive 200μL Liquid Handler, this electronic device completely bypasses the piston variations common in legacy manual pipettes. It features five specialized fluidic configurations, including an ultra-slow, smooth delivery script optimized specifically for precise gel electrophoresis loading and viscous sample handling. Built with a modular, quick-release architecture, it integrates an autoclavable lower section to guarantee strict biological isolation and prevent cross-contamination, offering material and life science laboratories an ergonomic, off-grid solution for high-throughput sample processing.

Technical Specifications

PARAMETER DETAILS
Product Model Atomfair-PIP284 (Version V2.0 | Release: 2024-01-27)
Volumetric Range 20 μL – 200 μL Continuous Electronic Control
Adjustment Increment 0.2 μL Fine Adjustment Intervals
System Accuracy (A) ≤ ±0.8% or ≤ ±1.6 μm Absolute Error Bound
Coefficient of Variation (CV) ≤ 0.2% or ≤ 0.4 μL Reproducibility Limit
Sterilization Standard Lower Module Fully Autoclavable at 121 °C for 20 minutes
Battery Cell Autonomy High-Capacity Rechargeable Core (Up to 4000 Cycles Per Full Charge)
Charging System Power 220V Euro-Style Dedicated Charging Adapter
Calibration Method Tool-Free Digital Panel Self-Calibration Interface
Instrument Net Weight 0.5 kg Balanced Lightweight Chassis
Alternative Options Explore our related catalog or custom dimensions. For urgent technical custom requests or bulk inquiries, please contact our support team.

Key Features & Advantages

  • Five Programmable Kinematic Modes: Features pre-configured digital scripts including PIP (Standard Transfer), PIPmix (Acoustic Sample Mixing), RevPIP (High-Viscosity Reversed Mode), GEL (Smooth Electrophoresis Profiling), and DISP (Multi-Alloquot Dispensing).
  • Tool-Free Electronic Calibration: Outfitted with an on-board software calibration system, allowing instant adjustments to maintain Grade-A precision bounds without physical disassembly keys.
  • Ergonomic Fatigue Mitigation: Incorporates an adjustable radial finger hook mechanism to relieve hand tendon strain during high-frequency, continuous multi-well plating cycles.
  • Universal Tip Interfacing: Universal lower cone coupling parameters support error-free seals with leading third-party pipette tip configurations via modular adapters.

APPLICATION SCOPE: Perfectly optimized for multi-channel ELISA immunoassays, gel loading, high-viscosity battery electrolyte micro-sampling, academic biochemistry diagnostics, and general food matrix analysis workflows.
PACKAGING: Shipped in a secure laboratory-grade box containing the 0.5 kg lightweight pipette body, 220V European charging dock, replacement adapters, and a certified calibration validation report.
IMPORTANT NOTICE: Detach the electronic upper handle completely prior to placing the lower fluidic assembly into an autoclave chamber. Never expose the LCD telemetry screen or charging ports to 121 °C high-pressure steam cycles.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The lower assembly of this electronic pipette is autoclavable at 121°C for 20 minutes, but repeated sterilization may affect calibration or seal integrity. Tip compatibility is ensured via mechanical adapters, with standard pipette tips within 20–200 μL being required for proper function.

  • Autoclave Sterilization Constraint: Autoclave the detachable lower part at 121°C for 20 minutes for sterilization and allow it to cool before reassembly.
  • Tip Compatibility Constraint: Use the supplied adapter to accommodate different pipette tip brands, but ensure tips are rated for 20–200 μL volume range.

How does the accuracy of the Atomfair electronic pipette vary across its volume range given the dual specification of ≤ ±0.8% or ≤ ±1.6 μL?

At the upper end of the 20–200 μL range, accuracy is governed by the ±0.8% specification (≤ ±1.6 μL at 200 μL), while at lower volumes the absolute limit of ±1.6 μL applies, corresponding to up to 8% error at 20 μL. The repeatability (CV) is ≤0.2% or ≤0.4 μL, ensuring precise performance across the range.

Can the Atomfair electronic pipette be used with standard universal pipette tips, or does it require proprietary tips?

The pipette is compatible with different tip brands via supplied adapters, but the description does not list specific tip models or dimensions. Users should test fit with their existing tips before routine use. The five operating modes (including RevPIP for high-viscosity or foaming liquids and GEL for gel electrophoresis) address diverse liquid handling constraints, but tip compatibility remains a separate verification step.

What are the sterilization and power requirements for the Atomfair electronic pipette?

Only the detachable lower part is autoclavable at 121 °C for 20 minutes; the electronic upper assembly must not be autoclaved. The pipette is powered by a rechargeable battery providing up to 4000 uses per full charge and requires a 220V Euro-style charger, which may necessitate a voltage converter for 110V laboratory power supplies.

The Atomfair Electronic Pipette 20-200μL provides five operating modes and an autoclavable lower assembly for versatile liquid handling in biology and chemistry labs. Users should note the 220V power requirement and the limitation that only the lower part is autoclavable.

Positive

  • Five versatile operating modes: Includes PIP, PIPmix, RevPIP, GEL, and DISP modes for standard pipetting, sample mixing, high-viscosity liquids, gel electrophoresis loading, and multiple dispensing.
  • Autoclavable lower assembly: The detachable lower part can be sterilized at 121°C for 20 minutes, ensuring aseptic liquid handling for sensitive applications.

Trade-offs

  • Non-autoclavable upper electronics: Only the lower part is autoclavable; the electronic upper assembly requires alternative cleaning methods, limiting full sterilization.
  • 220V power requirement: The pipette uses a 220V Euro-style charger, necessitating a voltage converter for operation in 110V regions or compatible infrastructure.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).