LFP & NCM811 Research Electrode Sheet Combo ATOMFAIR®

$237.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research grade LFP and NCM811 electrode sheet combo with 15.6, 24, and 60 mg/cm2 areal densities on aluminum foil, 5 pieces per pack. Order now.

SKU: AF-BM-S-C811LFP-ANS-5P
Category:
Brands:

ATOMFAIR® HIGH-PURITY ELECTRODE SHEET MULTI-SYSTEM COMBO PACK

RESEARCH GRADE MATERIAL | LFP & NCM811 COMBINATION BATCH

Product Overview

This premium Electrode Sheet Combo Pack provides a highly cost-effective, ready-to-use solution for advanced battery R&D. By pairing mainstream high-nickel ternary (NCM811) and lithium iron phosphate (LFP) systems, this kit eliminates labor-intensive slurry coating, rolling, and initial cutting phases. Strictly calibrated areal densities ensure consistent quality, baseline testing control, variable elimination, and electrolyte validation platform benefits across all coin cells, pouch cells, and small-scale experimental cell configurations.

Specification Details (5 Pieces per Pack, 3 Packs Total)

SYSTEM AREAL DENSITY STRUCTURE QUANTITY APPLICATION REMARKS
NCM811 24 mg/cm² Single-Side Coating 5 Pieces Ideal for single-side half-cell and counter electrode testing protocols.
NCM811 60 mg/cm² Double-Side Coating 5 Pieces Suitable for full-cell and high-load long-term cycle testing parameters.
LFP 15.6 mg/cm² Single-Side Coating 5 Pieces Perfect for conventional C-rate, routine cycling, and low-temperature performance profiles.
2. Core Material Parameters
Substrate Matrix Premium Aluminum Foil (conventional current collector, custom changes fully supported on demand).
Visual Properties Uniformly distributed active material deposition; zero exposed base foil borders, no dark spot anomalies, no powder shedding.
Physical Format Default square layout pieces (custom dimension cutting and pre-punched sizing options available upon request).
Manufacturing Rules Processed under strict laboratory research grade standard compliance to minimize intra-batch fluctuations.
Storage Parameters Store sealed inside a dedicated dry environment or glove box; recommended dew point threshold ≤ -40°C, isolated from light and ambient oxygen.


Product Selling Points & Scenarios

  • Precise Spec Calibration: Strictly regulated loading boundaries compatible with coin cells (CR2032/2025), pouch cell prototypes, and small cylindrical test cells.
  • Ready-to-Use Architecture: Pre-formed dry electrodes eliminate mixing, mechanical rolling, or specialized slot cutting, minimizing laboratory labor overheads.
  • Cost-Effective Combination: Integrated one-stop procurement of both NCM811 and LFP technologies, providing an economical alternative to individual batch setups.
  • Academic & Industrial Versatility: Ideal for university basic characterization, corporate additive evaluation, rate testing, impedance mapping, and formula debugging.

PACKAGING & LOGISTICS: Delivered as a combined 3-pack kit. Individual packages feature heavy-duty aluminum-plastic vacuum sealing accompanied by chemical desiccants. Outer transit cartons incorporate premium shockproof buffering. Both room temperature and cold-chain shipping options are supported.
USAGE GUIDANCE: Electrodes are supplied in a clean, fully dehydrated state. Unpack and handle exclusively inside an argon-filled glove box environment. Assemble cells immediately following containment release to prevent atmospheric moisture absorption or active surface oxidation paths. Take extra care during custom die-cutting to avoid micro-burrs or localized powder shedding along structural edges.
AFTER-SALES & WARRANTY TERMS: These materials are highly customized experimental consumables; standard unconditional returns are not supported absent verifiable manufacturing defects. Please inspect vacuum integrity and check specifications within 24 hours of arrival. Free replacement is guaranteed for documented transit damage, vacuum leakage, or incorrect configuration fulfillment. We provide standard technical usage data but assume no liability for cell assembly variations or outlying equipment test parameters.

TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or custom combination inquiries.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Defines the storage, atmospheric, and handling constraints for the Atomfair NCM811/LFP electrode sheet combo pack. Electrode sheets must remain sealed in a dry, oxygen-free environment until transferred to an argon-filled glove box, and must be assembled into cells promptly after unpacking.

  • Dry Storage: Store sealed electrode packs in a dedicated dry environment or glove box at a dew point no higher than -40°C, isolated from light and ambient oxygen.
  • Atmospheric Sensitivity: Open the electrode packages only inside an argon-filled glove box to prevent moisture absorption and active surface oxidation.
  • Assembly Timing: Assemble the electrode sheets into cells immediately after containment release to prevent atmospheric moisture absorption and active surface oxidation.
  • Die-Cutting Care: Take extra care during custom die-cutting to avoid micro-burrs or localized powder shedding along structural edges.

Describes the required sequence for unpacking and assembling the supplied dry electrode sheets in an inert atmosphere. Perform all container-opening and cell-assembly steps inside an argon-filled glove box with a dew point no higher than -40°C.

Required Equipment: Argon-filled glove box

  1. Inspect
    Inspect the incoming vacuum-sealed packs for transit damage, vacuum leakage, or incorrect configuration upon arrival.
  2. Transfer
    Transfer the sealed electrode packs into the argon-filled glove box before opening their vacuum packaging.
  3. Verify
    Verify the glove box dew point is no higher than -40°C before opening the sealed packs.
  4. Unpack
    Unpack the electrode sheets only inside the argon-filled glove box immediately after containment release.
  5. Assemble
    Assemble the intended coin, pouch, or small-scale test cells immediately after unpacking to prevent moisture absorption and active surface oxidation.

How do the areal densities of the NCM811 and LFP electrodes in this combo pack affect cell design and testing protocols?

The NCM811 electrodes are available in single-side (24 mg/cm²) and double-side (60 mg/cm²) coatings, while LFP is single-side at 15.6 mg/cm². The NCM811 single-side is ideal for half-cell and counter electrode testing, double-side for full-cell high-load long-term cycling, and LFP for conventional C-rate, routine cycling, and low-temperature performance profiles. This combination allows researchers to evaluate different chemistries and loading conditions within a single kit.

What are the specific cell format and environmental compatibility requirements for using these pre-coated electrode sheets?

These electrodes are designed for coin cells (CR2032/2025), pouch cell prototypes, and small cylindrical test cells. They must be handled exclusively in an argon-filled glove box after unpacking, and storage requires a sealed dry environment with dew point ≤ -40°C, isolated from light and ambient oxygen. Immediate cell assembly upon containment release is recommended to prevent atmospheric moisture absorption or active surface oxidation.

What are the critical storage and handling parameters to prevent degradation of these research-grade electrode sheets?

The electrodes must be stored sealed in a dry environment or glove box with dew point ≤ -40°C, protected from light and ambient oxygen. They are supplied in a clean, fully dehydrated state; unpack and handle only inside an argon-filled glove box. Custom die-cutting should be performed carefully to avoid micro-burrs or localized powder shedding along structural edges. Vacuum integrity should be inspected within 24 hours of arrival, and free replacement is available for documented transit damage or vacuum leakage.

This combo pack provides research-grade pre-coated NCM811 and LFP electrodes with calibrated areal densities (NCM811: 24 and 60 mg/cm²; LFP: 15.6 mg/cm²) on aluminum foil, ready for coin cell and pouch cell assembly, but requires strict inert atmosphere handling and storage below -40°C dew point to prevent degradation.

Positive

  • Precise Areal Density Calibration: Electrode sheets feature strictly calibrated areal densities (NCM811: 24 and 60 mg/cm²; LFP: 15.6 mg/cm²) ensuring consistent loading for reliable baseline testing and electrolyte validation across coin cell and pouch cell configurations.
  • Ready-to-Use Dry Electrode Format: Pre-formed dry electrodes eliminate slurry coating, rolling, and initial cutting steps, reducing labor overhead and enabling direct deployment in academic and industrial R&D workflows.

Trade-offs

  • Strict Dry Storage Requirement: Electrodes must be stored sealed in a dedicated dry environment or glove box with dew point ≤ -40°C, isolated from light and ambient oxygen, to prevent moisture absorption and surface oxidation.
  • Handling Sensitivity to Moisture and Oxygen: Unpacking and handling require an argon-filled glove box; cells must be assembled immediately after containment release to avoid atmospheric contamination. Extra care is needed during die-cutting to prevent micro-burrs or powder shedding.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).