Atomfair OilDetect 369 Fully Automatic Infrared Oil Analyzer
Product Overview
Atomfair OilDetect 369 Fully Automatic Infrared Oil Analyzer is a professional instrument specially designed for the measurement of oil, petroleum hydrocarbons, animal and vegetable oils in water. Developed in accordance with relevant international testing standards, it has the advantages of stable performance, high measurement accuracy and fast detection speed. It is widely used in laboratories, third-party testing institutions, research institutes, sewage treatment plants and other scenarios in petroleum, petrochemical, smelting, environmental protection, hydrology and water conservancy industries, providing efficient and reliable solutions for various water quality oil content detection.
Working Principle
Based on the principle of like dissolves like, oil substances in water are extracted into tetrachloroethylene, and oil measurement is realized after oil-water separation; petroleum hydrocarbons measurement can be completed after oil substances pass through the magnesium silicate adsorption column. Oil substances have absorption characteristics at the spectral bands with wave numbers of 2930cm⁻¹ (stretching vibration of C-H bond in CH₂ group), 2960cm⁻¹ (stretching vibration of C-H bond in CH₃ group) and 3030cm⁻¹ (stretching vibration of C-H bond in aromatic hydrocarbons). The instrument conducts qualitative and quantitative analysis of oil substances by utilizing the absorption and conversion of spectral energy.
Core Advantages
Accurate Detection
Strong Stability: Adopting cast aluminum base with natural stress aging treatment, excellent optical stability, mechanical positioning error less than 1 wave number.
Accurate Detection of Aromatic Hydrocarbons: Effectively detect benzene and toluene, the detection error of standard samples with different ratios is less than 3%, which meets the actual water sample detection requirements.
Multiple Guarantees for Accuracy: Simulate manual detection process to rinse pipelines and cuvettes; equipped with zero tracking technology, real-time zero adjustment, accurately locate and eliminate errors, making the influence of mechanical error and temperature drift close to zero.
Intelligent & Efficient
Fully Automatic Operation: Automatically complete the whole process operations such as tetrachloroethylene purity inspection, extractant addition, liquid-liquid extraction, oil-water separation, animal and vegetable oil separation, oil measurement, pipeline cleaning and automatic reagent recovery, without excessive manual intervention.
Multi-parameter Synchronous Measurement: Support simultaneous or separate measurement of three parameters: total oil, petroleum hydrocarbons, animal and vegetable oils. Adopt three-wave number correction coefficient method without additional standard curve drawing.
Flexible Sample Processing: Freely set 1-N sample positions and support discontinuous measurement; equipped with special sampling bottles, the volume can be read directly, samples can be directly loaded for extraction without secondary transfer.
Rapid Analysis: The whole detection process only takes about 10 minutes, and the extraction efficiency is more than 98%, which greatly improves the detection efficiency.
Adapt to Complex Water Quality: Applicable to various high-impurity water quality, can be directly tested on the machine without manual pretreatment and filtration; for high-concentration samples, when the detection result exceeds the threshold, the instrument will automatically dilute by a fixed multiple to ensure measurement accuracy.
Easy Operation
Multi-channel Communication Connection: Support Bluetooth, WiFi and wired communication, seamless connection with computers, mobile terminals and remote data platforms to achieve efficient data transmission and management.
Real-time Spectrum Display: Full wave number measurement and real-time spectrum display, convenient for users to fully grasp sample information, meeting the needs of both quantitative measurement and qualitative analysis.
Professional Software Support: Equipped with special oil measurement software (software copyright applied), integrating spectrum scanning, analysis, calculation and storage. The operation is simplified, flexible and visualized, supporting urgent sample addition and reducing operation difficulty.
Safe & Reliable
Personnel Health Protection: The instrument is designed with a special waste gas treatment channel to avoid staff contact with tetrachloroethylene, no need to use in a fume hood.
Classified Waste Liquid Treatment: Automatically store extractant and water samples in different waste liquid bottles respectively, reduce the amount of waste liquid treatment and lower environmental protection pressure.
Technical Parameters
Technical Index Specification Parameters
Wavelength Range 2941nm~4167nm
Wave Number Scanning Range 3400~2400cm⁻¹
Wave Number Accuracy ±1cm⁻¹
Wave Number Repeatability ±1cm⁻¹
Detection Limit 0.06 mg/L
Spectrum Resolution ±1cm⁻¹
Repeatability 1%
Accuracy 1%
Absorbance Range 0.0-2.000
Extraction Efficiency >95%
Number of Sample Positions 7/11 (Two configurations optional)
Number of Cleaning Positions 1
Extraction Ratio (100~5):1
Sample Addition Error 0.05ml
Measurement Range 0.24-100mg/L
Baseline Drift 1%/4h
Oil-water Separation Method Membrane Separation
Error of Different Ratios <3%
Maximum Water Sample Volume 750mL
Automatic Reagent Inspection Supported
Magnesium Silicate Switching Mode Manual & Automatic (Two configurations optional)
Overall Dimension (mm) Pretreatment device: 530×450×722; Main unit: 540×310×200
Weight (kg) Pretreatment device: 25; Main unit:14
If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.
The instrument requires the use of tetrachloroethylene as an extractant, a hazardous solvent that must be handled with care; the built‑in waste gas treatment channel and classified waste liquid bottles minimize operator exposure and environmental impact. The optical system uses a cast‑aluminum base with natural stress aging and zero‑tracking technology to maintain accuracy despite mechanical and thermal drift.
- Tetrachloroethylene Handling: Tetrachloroethylene is used as the extraction solvent; the instrument includes a waste gas treatment channel to avoid direct contact, and the extractant is automatically recovered and stored in a dedicated waste liquid bottle.
- Waste Liquid Segregation: The instrument automatically separates extractant and water samples into different waste liquid bottles to reduce treatment volume and environmental burden.
- High‑Concentration Sample Auto‑Dilution: When the measurement result exceeds the threshold, the instrument automatically dilutes the sample by a fixed multiple to maintain accuracy.
Load the water sample directly into the provided special sampling bottle, place it in the instrument, and set the desired sample positions via the software. The instrument then automatically performs reagent inspection, extraction, separation, measurement, and cleaning without manual intervention.
Required Equipment: Atomfair OilDetect 369 Fully Automatic Infrared Oil Analyzer, Special sampling bottle (supplied), Tetrachloroethylene extractant
- Load Sample
Fill the special sampling bottle with the water sample and place it into the instrument's sample position. - Configure Parameters
Use the professional oil measurement software to set the number and order of sample positions and select the parameters to measure. - Start Analysis
Initiate the automatic analysis sequence; the instrument will inspect the tetrachloroethylene purity, add extractant, perform liquid‑liquid extraction, separate phases, measure the oil content, and clean the system. - Monitor Results
Observe the real‑time spectrum display and the final measured values for total oil, petroleum hydrocarbons, and animal/vegetable oils as they appear on the software interface.
What is the detection limit of the Atomfair OilDetect 369 and how does it handle samples exceeding the measurement range?
The detection limit is 0.06 mg/L with a standard measurement range of 0.24–100 mg/L. When a sample exceeds the upper threshold, the instrument automatically applies a fixed dilution factor to bring the concentration within range, ensuring accuracy without manual re-preparation.
Can the OilDetect 369 measure total oil, petroleum hydrocarbons, and animal/vegetable oils in a single run, and does it require sample filtration for turbid waters?
Yes, it supports simultaneous or separate measurement of all three parameters using a three-wave number correction method without additional calibration curves. The instrument is designed for high-impurity water and can process samples directly without manual pretreatment or filtration, using membrane separation for oil-water separation.
What safety measures are integrated to minimize operator exposure to tetrachloroethylene during automated oil analysis?
A dedicated waste gas treatment channel routes fumes away from the operator, eliminating the need for a fume hood. The system also automatically stores extractant and water samples in separate waste liquid bottles, reducing hazardous waste handling and environmental burden.
The Atomfair OilDetect 369 is a fully automatic infrared oil analyzer that extracts oil from water into tetrachloroethylene and quantifies total oil, petroleum hydrocarbons, and animal/vegetable oils via three-wave-number spectral analysis. Its cast aluminum base with natural stress aging ensures optical stability, while automated dilution and waste segregation support high-impurity water samples and safe operation without a fume hood.
Positive
- High optical stability and accuracy: The cast aluminum base with natural stress aging provides excellent optical stability with mechanical positioning error less than 1 cm⁻¹, and the three-wave-number correction method achieves detection error under 3% for different aromatic ratios, ensuring reliable quantitative results.
- Fully automated and efficient workflow: The instrument automates tetrachloroethylene purity inspection, extraction, oil-water separation, measurement, pipeline cleaning, and reagent recovery, completing the full process in about 10 minutes with extraction efficiency over 98%, significantly reducing manual intervention and improving throughput.
Trade-offs
- Requires specific solvent and waste management: The analyzer relies on tetrachloroethylene as the extraction solvent, which is a hazardous chemical. Although the instrument includes a waste gas treatment channel and segregated waste liquid bottles, users must still handle and dispose of the solvent and waste streams according to environmental and safety regulations.
- Limited measurement range and sample volume: The measurement range is 0.24-100 mg/L with a maximum water sample volume of 750 mL, and the extraction ratio is fixed at (100~5):1. High-concentration samples require automatic dilution, which may extend analysis time and add complexity for samples exceeding the upper limit.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).