PLUG-IN VACUUM RELEASE TRAY 400 GRID LOW ADHESION,5pcsRESEARCH GRADE MATERIAL
|
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||
This vacuum release tray requires a compatible vacuum station and pump system for sample release. The product is packaged under dry inert nitrogen gas to prevent contamination and must be stored in a clean, dry environment to maintain adhesive integrity.
- Vacuum Station Compatibility: The tray must be used exclusively with a compatible vacuum station and vacuum pump to activate the release mode for sample removal.
- Handling and Storage Conditions: Store the double-vacuum-sealed tray in a cleanroom environment at ambient temperature and avoid exposure to moisture or particulates until use.
- ESD Protection Requirements: The integrated anti-static and conductive components require proper grounding of the workstation to prevent electrostatic discharge damage to sensitive samples.
- Sample Detachment Protocol: Apply vacuum gradually to release the low-adhesion platform without causing micro-shifting or residue transfer on delicate samples.
- Ordering Specifications for Mesh: Alternative mesh densities or colors must be explicitly stated in the order remarks, as the default configuration is white 16 mesh.
This procedure describes the safe and effective use of the vacuum release tray to detach samples without damage. The tray must be paired with a compatible vacuum station and pump to achieve controlled release.
Required Equipment: Compatible Vacuum Station, Compatible Vacuum Pump
- Place the tray on the vacuum station
Position the atomfair vacuum release tray onto the vacuum station, ensuring the tray’s base aligns with the station’s sealing interface. - Connect the vacuum pump
Attach the vacuum pump hose to the station’s port and verify a secure, leak-free connection. - Activate the vacuum pump
Turn on the pump and gradually increase vacuum pressure until the tray’s low-adhesion platform releases the samples. - Remove released samples
Once the samples are detached, carefully lift them from the tray using cleanroom tweezers or a vacuum wand.
How does the 400-grid compartment size and low adhesion platform prevent micro-shifting and residue transfer for delicate samples?
The 400-grid array with 1.52×1.44 mm compartments provides precise cell-by-cell isolation, while the low surface energy adhesive platform eliminates microscopic residue and stress marks upon sample detachment. This prevents thin-film peeling or device deformation, as stated in the product's Key Features.
What external equipment is required to operate the vacuum release function of this tray?
The vacuum release tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system to activate Release Mode for sample removal. The product description explicitly links to Atomfair's Vacuum Station and Vacuum Pump models as required infrastructure.
What storage and handling conditions preserve the low adhesion and ESD properties of these trays?
The trays are shipped double-vacuum sealed under dry inert nitrogen to guarantee zero contamination during transport. The integrated anti-static matrices and conductive polymer backings provide ESD dissipation, and the chemical-resistant components withstand continuous outgassing; storage in a clean, dry environment per the included cleanroom compliance certificate is recommended.
Atomfair's 400-grid low adhesion vacuum release tray provides precise sample isolation with non-destructive detachment, but requires external vacuum system support and explicit mesh customization for non-default configurations.
Positive
- Precise 20×20 grid array isolation: The orthogonal 400-grid configuration facilitates systematic cell-by-cell micro-mapping, clean optical screening, and efficient batch sample cataloging.
- Low residue non-destructive detachment: The low surface energy adhesive platform enables reliable sample hold with micro-level non-destructive detachment, preventing thin-film peeling or device deformation during removal.
Trade-offs
- Requires external vacuum equipment: The vacuum release tray must be used with a compatible vacuum station and vacuum pump to activate the release mode for sample removal, adding system infrastructure requirements.
- Default mesh may require customization: The standard configuration ships with white 16 mesh; alternative mesh densities or colors must be explicitly specified in order remarks, which may add lead time or complexity.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).