Vacuum Release Tray 30 Grid, Medium Adhesion ATOMFAIR®

$75.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

30-grid 2×15 plug-in vacuum release tray, medium adhesion, for non-destructive sample detachment. ESD-safe options, 5 pcs pack, cleanroom certificate included.

SKU: AF-EI-A-PVRT-030M-CB00-PARENT
Category:
Brands:

PLUG-IN VACUUM RELEASE TRAY 30 GRID MEDIUM ADHESION,5pcs

RESEARCH GRADE MATERIAL

Product Overview

The atomfair plug-in vacuum release tray is specifically engineered for critical research environments demanding high-purity, contamination-free, and cross-contamination-proof sample containment alongside meticulous microscopic particulate regulation. This specific configuration features a precision-molded 2×15 Grid Array matrix combined with an advanced Medium surface energy adhesive platform. It is custom-designed to prevent micro-shifting or structural dislodgement during rigorous transport, while simultaneously eliminating microscopic surface residue, adhesive transfer, or localized stress marks upon sample detachment. This non-destructive preservation platform is critical for advanced materials processing, quantum device fabrication, and delicate structural analysis across national frameworks and multi-disciplinary university core labs.

Technical Specifications

PARAMETER DETAILS
1. Core Specification Profile
Grid Configuration 30 Grid (2×15 Array, 11.81×1.52 mm Compartments)
Adhesion Level Medium Adhesion
2. Material Configurations & Ordering Codes
Model: AF-VRA-30M-CB ESD-safe full-black lid + conductive black tray + black insert
Model: AF-VRA-30M-CC Conductive full-black lid + conductive black tray + black insert
Model: AF-VRA-30M-CT ESD-safe clear lid + conductive black tray + clear insert
3. Mesh Selection Matrix
Default Mesh Specification White 16 Mesh
Available Mesh Densities 16 Mesh / 33 Mesh / 76 Mesh / 103 Mesh / 137 Mesh / 195 Mesh
Available Mesh Color Options Standard White Mesh / Yellow Mesh
Ordering Remark Guide If you need to purchase alternative mesh colors or densities, please explicitly state your specific requirements in the order remarks section during checkout.

Key Features & Advantages

  • Precise 2×15 Matrix Isolation: The orthogonal 30-grid configuration facilitates systematic cell-by-cell micro-mapping, clean optical screening, and efficient batch sample cataloging.
  • Medium Residue Surface Energy: Specially structural elastomer allows reliable anchor hold while ensuring micro-level non-destructive sample detachment, preventing thin-film peeling or device deformation.
  • Comprehensive ESD Protection: Integrated anti-static matrices and premium conductive polymer backings provide immediate dissipative pathways to eliminate high-voltage electrostatic field disruptions.
  • Vacuum & Structural Integrity: Engineered with premium chemical-resistant components to withstand continuous outgassing and multi-cycle depressurization without dimensional warping.

APPLICATION SCOPE: Highly recommended for quantum optics (qubit chips), materials science (2D films, graphene, nanomaterials), semiconductor R&D (MEMS, bare dies, compound wafers), and specialized biotechnology biosensor microfluidic arrays.
PACKAGING: Contains 5 × atomfair plug-in vacuum release tray (30 Grid / Medium Adhesion), 1 × cleanroom compliance certificate, and shock-absorbent shells. Double-vacuum bag sealed under dry inert nitrogen gas atmosphere to guarantee zero contamination during transport.
IMPORTANT ORDERING NOTICE: The default baseline configuration provided is white 16 mesh. If your project mandates alternative mesh counts (33, 76, 103, 137, or 195) or a yellow mesh configuration, please explicitly state your specific color and density requirements within the order remarks field during checkout confirmation.
SYSTEM REQUIREMENT: To activate the Release Mode for sample removal, this vacuum release tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This tray requires a compatible vacuum station and vacuum pump to activate the release mechanism for sample removal. The adhesive platform is designed for medium adhesion and may require validation for compatibility with specific sample substrates to prevent residue transfer.

  • Vacuum System Requirement: The tray must be used with a compatible vacuum station and vacuum pump to activate the Release Mode for sample removal.
  • Inert Atmosphere Packaging: The tray is double-vacuum bag sealed under dry inert nitrogen to guarantee zero contamination during transport, requiring careful unpacking in a controlled environment.
  • Mesh Customization: Alternative mesh densities (16, 33, 76, 103, 137, or 195) and mesh colors (white or yellow) must be specified at time of order as the default is white 16 mesh.
  • Adhesion Performance: The medium adhesion layer is designed for non-destructive detachment but may exhibit residue if used with incompatible sample surfaces.
  • ESD Protection: The ESD-safe and conductive materials provide dissipative pathways, but the tray must be properly grounded to ensure electrostatic discharge protection.

This procedure outlines the steps to securely load samples into the vacuum release tray and safely detach them using a vacuum station and pump. Proper alignment and activation of the vacuum system are critical to prevent sample damage or contamination.

Required Equipment: Vacuum Station, Vacuum Pump

  1. Unpack Tray
    Inspect the double-vacuum bag for integrity and carefully open it in a cleanroom environment to maintain the inert atmosphere.
  2. Mount Tray on Station
    Mount the tray onto the compatible vacuum station, ensuring proper alignment and a secure fit.
  3. Connect Vacuum Pump
    Connect the vacuum pump to the station and verify that all seals are airtight.
  4. Load Samples
    Place each sample into a designated grid compartment using clean tweezers to avoid cross-contamination.
  5. Activate Vacuum
    Activate the vacuum through the station to secure the samples in place for processing or transport.
  6. Release Samples
    Deactivate the vacuum and engage the release mode on the station to detach samples without residue or damage.

How does the medium adhesion platform of the Atomfair 30-grid vacuum release tray balance sample retention during transport with non-destructive release for delicate devices?

The medium adhesion platform uses a specially structured elastomer that provides a reliable anchor hold to prevent micro-shifting or structural dislodgement during transport, while enabling micro-level non-destructive sample detachment without thin-film peeling or device deformation. This eliminates microscopic surface residue, adhesive transfer, or localized stress marks upon removal, making it suitable for advanced materials processing and quantum device fabrication.

What infrastructure is required to operate the Atomfair vacuum release tray's Release Mode for sample detachment?

To activate the Release Mode for sample removal, the Atomfair vacuum release tray must be used in conjunction with a compatible Vacuum Station and Vacuum Pump system, as stated in the product's system requirement. No other method of detachment is specified for non-destructive release.

How does the packaging of the Atomfair vacuum release tray maintain cleanroom-grade purity during transport and storage?

The trays are double-vacuum bag sealed under a dry inert nitrogen gas atmosphere to guarantee zero contamination during transport. Each package includes 5 trays with a cleanroom compliance certificate and shock-absorbent shells, ensuring the samples remain uncontaminated for critical research environments.

The atomfair plug-in vacuum release tray (30 grid, medium adhesion) offers precision sample isolation with non-destructive release for sensitive substrates, though operation requires a dedicated vacuum station and pump, and default mesh may not suit all applications.

Positive

  • Precise 2×15 grid matrix: The 30-grid orthogonal configuration enables systematic cell-by-cell mapping, clean optical screening, and efficient batch sample cataloging for advanced materials and device fabrication.
  • Non-destructive medium adhesion: The specially structured elastomer provides reliable hold during transport while allowing micro-level sample detachment without residue, stress marks, or thin-film peeling.

Trade-offs

  • Requires external vacuum system: Release mode activation and sample removal depend on a compatible vacuum station and vacuum pump, adding infrastructure requirements and potential additional cost.
  • Default mesh may not fit all processes: The standard white 16 mesh must be explicitly changed via order remarks if alternative mesh densities (33–195) or color (yellow) are needed, introducing a potential ordering oversight risk.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Specification

ESD-safe full-black lid + conductive black tray + black insert 5pcs, Conductive full-black lid + conductive black tray + black insert 5pcs, ESD-safe clear lid + conductive black tray + clear insert 5pcs