SpectraCore UV 1000 UV-Visible Spectrophotometer, 200-1000 nm, 4.0 nmProduct Type: UV-Visible Spectrophotometer
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The instrument requires a stabilized power supply of 110/220 V, 50/60 Hz and a warm-up period to achieve specified stability. Operators must avoid direct exposure to the UV light emitted by the deuterium lamp to prevent eye and skin injury.
- Power Supply Requirements: Connect the instrument to a grounded AC power outlet providing 110/220 V, 50/60 Hz with a maximum power consumption of 120 W.
- UV Light Safety: Do not open the sample compartment while the deuterium lamp is energized, as UV radiation can cause eye damage and skin burns.
How does the 4.0 nm bandwidth of the SpectraCore UV 1000 affect measurement accuracy for samples with narrow absorption peaks?
The 4.0 nm bandwidth is a standard specification suitable for routine quantitative analysis but may not resolve closely spaced or narrow absorption peaks. The instrument provides wavelength accuracy of ±2 nm and photometric accuracy of ±0.003 A at 0.5 A, which are adequate for general absorbance and transmittance measurements. For applications requiring higher spectral resolution, an instrument with a narrower bandwidth would be necessary.
Can the SpectraCore UV 1000 be used with microvolume or fiber optic sampling accessories?
The product description specifies a standard 4-position cell holder for 10 mm cuvettes, and no microvolume or fiber optic accessory compatibility is explicitly stated. The instrument includes a USB port and a printer port, but no fiber optic interface is mentioned. Users should confirm accessory compatibility with the technical sales team (inquiry@atomfair.com) before ordering non-standard sampling accessories.
What are the power and environmental requirements for installing the SpectraCore UV 1000 in a laboratory?
The instrument operates on 110/220 V, 50/60 Hz, 120 W, compatible with standard laboratory outlets. It weighs 14.6 kg and has dimensions of 475 x 360 x 225 mm, requiring a stable benchtop. The stability specification of ≤0.001 A/h at 500 nm after warm-up indicates that a consistent temperature and vibration-free environment is needed to maintain photometric performance.
The SpectraCore UV 1000 is a single-beam UV-Visible spectrophotometer covering 200-1000 nm with 4.0 nm bandwidth, offering ±0.003 A photometric accuracy at 0.5 A and ≤0.001 A/h stability after warm-up, suitable for standard absorbance and transmittance measurements in routine lab workflows.
Positive
- Broad UV-Vis wavelength coverage: The 200-1000 nm range supports both UV and visible wavelength applications, enabling versatile method development for absorbance and transmittance measurements.
- High photometric accuracy: Photometric accuracy of ±0.003 A at 0.5 A and ±0.006 A at 1.0 A ensures reliable quantitative analysis for trace-level and routine concentration measurements.
Trade-offs
- Single-beam optical design: The single-beam system requires manual baseline correction and is more susceptible to lamp drift over time, demanding careful protocol execution for reproducible results.
- Requires warm-up for stability: The stability specification of ≤0.001 A/h is only achieved after warm-up, meaning the instrument must be powered on and stabilized before use, adding time to measurement workflows.