UV-Visible Spectrophotometer 200-1000 nm 4.0 nm ATOMFAIR®

$1,572.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Single-beam UV-visible spectrophotometer with 200-1000 nm range, 4.0 nm bandwidth, ±2 nm accuracy, USB output and 10 mm 4-cell holder. Order now.

SKU: AF-EI-S-UVVS-2001-S104
Category:
Tags: , , ,
Brands:

Description

SpectraCore UV 1000 UV-Visible Spectrophotometer, 200-1000 nm, 4.0 nm

Product Type: UV-Visible Spectrophotometer
Research-grade laboratory product

Product Overview

UV-Visible Spectrophotometer with 200-1000 nm, 4.0 nm and -0.3 to 3.0 A, 0 to 200%T supports absorbance, transmittance and concentration measurements.

The specification table keeps optical system, light source, wavelength, photometric, sample holder, output and dimensional data visible for method selection and procurement review.

Performance Features

  • Wavelength range of 200-1000 nm defines visible or UV-visible measurement coverage.
  • Bandwidth of 4.0 nm supports method and resolution selection.
  • Photometric range of -0.3 to 3.0 A, 0 to 200%T supports absorbance and transmittance workflows.
  • Wavelength accuracy of ±2 nm supports measurement reliability review.
  • Stray light specification of ≤0.2%T at 360 nm supports optical performance comparison.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-SPECUV1000-200TO1000NM
Optical system Single beam
Light source Tungsten lamp (Japan HYBEC); deuterium lamp on UV models
Photometric range -0.3 to 3.0 A, 0 to 200%T
Sample holder 4-position cell holder, 10 mm
Display Backlit LCD screen
Output USB port and printer port
Dimensions (L x W x H) 475 x 360 x 225 mm
Bandwidth 4.0 nm
Wavelength range 200-1000 nm
Wavelength accuracy ±2 nm
Wavelength repeatability ≤1 nm
Photometric accuracy ±0.003 A at 0.5 A; ±0.006 A at 1.0 A; ±0.5%T at 100%T
Photometric repeatability ≤0.0015 A at 0.5 A; ≤0.003 A at 1.0 A; ≤0.25%T at 100%T
Stability ≤0.001 A/h at 500 nm after warm-up
Stray light ≤0.2%T at 360 nm
Power requirement 110/220 V, 50/60 Hz, 120 W
Weight 14.6 kg

Selection and Use Notes

  • Confirm wavelength range, bandwidth, optical system and sample holder format before quotation.
  • Confirm accessory compatibility, optical path length, reference code and measurement workflow when ordering holders, lamps, filters or standards.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The instrument requires a stabilized power supply of 110/220 V, 50/60 Hz and a warm-up period to achieve specified stability. Operators must avoid direct exposure to the UV light emitted by the deuterium lamp to prevent eye and skin injury.

  • Power Supply Requirements: Connect the instrument to a grounded AC power outlet providing 110/220 V, 50/60 Hz with a maximum power consumption of 120 W.
  • UV Light Safety: Do not open the sample compartment while the deuterium lamp is energized, as UV radiation can cause eye damage and skin burns.

How does the 4.0 nm bandwidth of the SpectraCore UV 1000 affect measurement accuracy for samples with narrow absorption peaks?

The 4.0 nm bandwidth is a standard specification suitable for routine quantitative analysis but may not resolve closely spaced or narrow absorption peaks. The instrument provides wavelength accuracy of ±2 nm and photometric accuracy of ±0.003 A at 0.5 A, which are adequate for general absorbance and transmittance measurements. For applications requiring higher spectral resolution, an instrument with a narrower bandwidth would be necessary.

Can the SpectraCore UV 1000 be used with microvolume or fiber optic sampling accessories?

The product description specifies a standard 4-position cell holder for 10 mm cuvettes, and no microvolume or fiber optic accessory compatibility is explicitly stated. The instrument includes a USB port and a printer port, but no fiber optic interface is mentioned. Users should confirm accessory compatibility with the technical sales team (inquiry@atomfair.com) before ordering non-standard sampling accessories.

What are the power and environmental requirements for installing the SpectraCore UV 1000 in a laboratory?

The instrument operates on 110/220 V, 50/60 Hz, 120 W, compatible with standard laboratory outlets. It weighs 14.6 kg and has dimensions of 475 x 360 x 225 mm, requiring a stable benchtop. The stability specification of ≤0.001 A/h at 500 nm after warm-up indicates that a consistent temperature and vibration-free environment is needed to maintain photometric performance.

The SpectraCore UV 1000 is a single-beam UV-Visible spectrophotometer covering 200-1000 nm with 4.0 nm bandwidth, offering ±0.003 A photometric accuracy at 0.5 A and ≤0.001 A/h stability after warm-up, suitable for standard absorbance and transmittance measurements in routine lab workflows.

Positive

  • Broad UV-Vis wavelength coverage: The 200-1000 nm range supports both UV and visible wavelength applications, enabling versatile method development for absorbance and transmittance measurements.
  • High photometric accuracy: Photometric accuracy of ±0.003 A at 0.5 A and ±0.006 A at 1.0 A ensures reliable quantitative analysis for trace-level and routine concentration measurements.

Trade-offs

  • Single-beam optical design: The single-beam system requires manual baseline correction and is more susceptible to lamp drift over time, demanding careful protocol execution for reproducible results.
  • Requires warm-up for stability: The stability specification of ≤0.001 A/h is only achieved after warm-up, meaning the instrument must be powered on and stabilized before use, adding time to measurement workflows.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).