UV-Visible Spectrophotometer 190-1100 nm 1.0 nm ATOMFAIR®

$2,541.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade UV-Visible Spectrophotometer with 190-1100 nm range, 1.0 nm bandwidth, ±0.1 nm accuracy, and 10.1-inch touch screen. Order now.

SKU: AF-EI-S-UVVS-1901-S211
Category:
Tags: , , ,
Brands:

Description

SpectraCore UV 2101 UV-Visible Spectrophotometer, 190-1100 nm, 1.0 nm

Product Type: UV-Visible Spectrophotometer
Research-grade laboratory product

Product Overview

UV-Visible Spectrophotometer with 190-1100 nm, 1.0 nm and -0.3 to 3.0 A; 0-9999 C; 0-9999 F supports absorbance, transmittance and concentration measurements.

The specification table keeps optical system, light source, wavelength, photometric, sample holder, output and dimensional data visible for method selection and procurement review.

Performance Features

  • Wavelength range of 190-1100 nm defines visible or UV-visible measurement coverage.
  • Bandwidth of 1.0 nm supports method and resolution selection.
  • Photometric range of -0.3 to 3.0 A; 0-9999 C; 0-9999 F supports absorbance and transmittance workflows.
  • Wavelength accuracy of ±0.1 nm at 656.1 nm; ±0.3 nm full range supports measurement reliability review.
  • Stray light specification of ≤0.03%T at 220 and 360 nm; ≤0.02%T on selected models supports optical performance comparison.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-SPECUV2101-190TO1100NM
Optical system Single beam
Light source Tungsten lamp plus deuterium lamp
Bandwidth 1.0 nm
Wavelength range 190-1100 nm
Wavelength accuracy ±0.1 nm at 656.1 nm; ±0.3 nm full range
Scanning speed High, medium and low
Wavelength repeatability ≤0.1 nm
Photometric range -0.3 to 3.0 A; 0-9999 C; 0-9999 F
Photometric repeatability ±0.001 A from 0-0.5 A; ±0.0015 A from 0.5-1 A
Stability ≤0.001 A/h at 500 nm
Stray light ≤0.03%T at 220 and 360 nm; ≤0.02%T on selected models
Sample holder 4-position cell holder, 10 mm; fixed long-cell holder option
Display 10.1-inch capacitive touch screen, 1024 x 600
Output USB port and printer port
Power requirement 110/220 V, 50/60 Hz, 120 W
Dimensions (L x W x H) 570 x 440 x 210 mm
Weight 20 kg

Selection and Use Notes

  • Confirm wavelength range, bandwidth, optical system and sample holder format before quotation.
  • Confirm accessory compatibility, optical path length, reference code and measurement workflow when ordering holders, lamps, filters or standards.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The SpectraCore UV 2101 requires a 110/220 V, 50/60 Hz, 120 W power supply for operation. The instrument uses a single-beam optical system with a 4-position cell holder for 10 mm pathlength cuvettes, with a fixed long-cell holder option available.

  • Power Supply: Connect the instrument to a grounded power outlet providing 110/220 V, 50/60 Hz, 120 W; do not use with ungrounded or non-specification power sources.
  • Sample Holder Compatibility: The standard sample holder accepts only 10 mm pathlength cuvettes in a 4-position cell holder; alternative cuvette formats require the optional fixed long-cell holder.

How does the photometric repeatability of the SpectraCore UV 2101 vary across the absorbance range?

The photometric repeatability is specified as ±0.001 A from 0 to 0.5 A and ±0.0015 A from 0.5 to 1 A, indicating higher precision at lower absorbance values. This specification supports reliable quantitative analysis within the linear absorbance range.

What cuvette path lengths are compatible with the SpectraCore UV 2101 sample holder?

The standard 4-position cell holder accepts 10 mm path length cuvettes. A fixed long-cell holder option is available for measurements requiring longer path lengths, providing flexibility for analyzing dilute samples.

What are the bench space and power requirements for installing the SpectraCore UV 2101?

The instrument measures 570 x 440 x 210 mm and weighs 20 kg, requiring a stable laboratory bench. It operates on 110/220 V, 50/60 Hz with a power consumption of 120 W.

The SpectraCore UV 2101 is a research-grade single-beam spectrophotometer offering 1.0 nm bandwidth and high wavelength accuracy across the UV-Vis range, suitable for standard absorbance and transmittance analyses. Its low stray light and stable photometric performance support reliable quantitative measurements.

Positive

  • High wavelength accuracy and repeatability: Wavelength accuracy of ±0.1 nm at 656.1 nm and ±0.3 nm full range, with repeatability ≤0.1 nm, ensures precise spectral positioning for quantitative analysis.
  • Low stray light and stable photometric performance: Stray light ≤0.03%T at 220 and 360 nm (≤0.02%T on selected models) and photometric stability ≤0.001 A/h at 500 nm enable reliable absorbance measurements even at high optical densities.

Trade-offs

  • Single-beam optical system requires baseline correction: The single-beam design necessitates periodic baseline correction before each measurement set to compensate for lamp drift and environmental changes, adding procedural steps.
  • Stray light may limit accuracy at high absorbance: With stray light ≤0.03%T at key wavelengths, accuracy at absorbance values above 2 A may be degraded compared to instruments with lower stray light specifications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).