TopPette Single-Channel 200-1000 μL Pipette ATOMFAIR®

$19.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

TopPette single-channel manual pipette with 200-1000 µL range, 5 µL increment, ISO 8655-2 calibration reference and lower-half autoclavability. Order now.

SKU: AF-EI-L-TOPP-N1K0-SC00
Category: ,
Tags:
Brands:

Description

TopPette Single-channel 200-1000 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette Single-channel 200-1000 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 200-1000 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 200-1000 µL working range, 5 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 200-1000 µL with 5 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-200-1000-µL
Product Family TopPette
Channel count Single-channel
Volume range 200-1000 µL
Increment 5 µL
Test volume(s) 1000 / 500 / 200 µL
Systematic error At 1000 µL: ±6.00 µL (±0.60%); at 500 µL: ±3.50 µL (±0.70%); at 200 µL: ±1.80 µL (±0.90%)
Random error At 1000 µL: ±2.00 µL (±0.20%); at 500 µL: ±1.25 µL (±0.25%); at 200 µL: ±0.60 µL (±0.30%)
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Regular calibration per ISO 8655-2 is required to maintain accuracy within the stated systematic and random error limits. Sterilization must be limited to the lower half of the pipette body when autoclavable indicator is present.

  • Calibration Requirement: Calibrate the pipette at the three test volumes (1000, 500, 200 µL) using ISO 8655-2 protocol to validate error tolerances.
  • Sterilization Constraint: Only the lower half of the pipette body may be autoclaved; the upper handle and volume adjustment mechanism must not be exposed to steam.
  • Volume Increment Constraint: Set the volume in 5 µL increments using the locking mechanism; intermediate volumes are not possible.
  • Tip Fit Requirement: Use only pipette tips designed for 200-1000 µL single-channel pipettors to ensure a consistent seal and accurate delivery.

How does the systematic error of the TopPette 200–1000 µL pipette vary across its working range, and does it meet ISO 8655-2 requirements at all test volumes?

The systematic error is volume-dependent: at 200 µL it is ±1.80 µL (±0.90%), at 500 µL ±3.50 µL (±0.70%), and at 1000 µL ±6.00 µL (±0.60%). Random error follows a similar trend: ±0.60 µL (±0.30%) at 200 µL, ±1.25 µL (±0.25%) at 500 µL, and ±2.00 µL (±0.20%) at 1000 µL. The pipette is calibrated per ISO 8655-2, and the published error values are within typical tolerances for manual pipettes at these volumes.

Can the TopPette 200–1000 µL pipette be fully sterilized, and what tip types are recommended for use with viscous or volatile liquids?

Only the lower half of the pipette is autoclavable; the upper assembly should not be autoclaved. For viscous or volatile liquids, low-retention or positive-displacement tips are recommended to minimize carryover and evaporation errors. The pipette is designed for standard 200–1000 µL tips (e.g., universal or Atomfair brand), but always confirm tip fit with the manufacturer.

Does the TopPette 200–1000 µL pipette support user calibration, and what is the calibration reference?

Yes, the pipette supports user calibration per ISO 8655-2, as indicated in the technical table. The calibration reference is provided for the test volumes of 200, 500, and 1000 µL. For the specific recalibration procedure, including the use of the adjustment tool, contact Atomfair technical support.

The TopPette Single-channel 200–1000 µL pipette provides a fully autoclavable lower half and ISO 8655-2 traceable calibration data, but its accuracy degrades to ±0.90% at 200 µL and only partial sterilization is supported, requiring careful volume and workflow planning.

Positive

  • Lower half autoclavable: The lower half of the pipette can be autoclaved, allowing sterilization without compromising the entire instrument.
  • ISO 8655-2 calibration reference: Systematic and random error values are provided for each test volume, enabling traceable performance verification and calibration management.

Trade-offs

  • Accuracy decreases at lower volumes: At 200 µL, systematic error is ±0.90% (±1.80 µL), which may limit precision for high-accuracy applications near the lower end of the range.
  • Partial sterilization limitation: Only the lower half is autoclavable and only where indicated; users must confirm sterilization suitability and may need to manually decontaminate the upper half.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).