$168.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

12-channel TopPette manual pipette with 10–100 μL range, 1 μL increments, ISO 8655-2 calibration reference and lower-half autoclaving. Order now.

SKU: AF-EI-L-TOPP-F100-12CH
Category: ,
Tags:
Brands:

Description

TopPette 12-channel 10-100 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette 12-channel 10-100 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 10-100 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 10-100 µL working range, 1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 10-100 µL with 1 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-12CHANNEL-10-100-µL
Product Family TopPette
Channel count 12-channel
Volume range 10-100 µL
Increment 1 µL
Test volume(s) 100 / 50 / 10 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Only the lower half of the pipette is autoclavable; the upper assembly must not be exposed to steam sterilization. Calibration must be performed by the user according to ISO 8655-2 to maintain specified systematic and random error at the test volumes.

  • Sterilization Constraint: Only the lower half of the pipette is autoclavable; disassemble the lower assembly before autoclaving and keep the upper body dry.
  • Calibration Requirement: Calibration must follow ISO 8655-2 procedures, validating systematic and random error at 10 µL, 50 µL, and 100 µL test volumes.
  • Tip Compatibility: Only compatible pipette tips must be used to ensure accurate volume delivery and a secure seal.

How does the systematic error of the TopPette 12-channel pipette vary across its 10-100 µL range?

The systematic error is specified at three test volumes (100, 50, and 10 µL) according to the technical table. The pipette provides a 1 µL increment, and the error values are retained in the product documentation for calibration review. For precise error figures, refer to the supplied calibration data per ISO 8655-2.

Which microplate formats are compatible with the TopPette 12-channel pipette for high-throughput workflows?

The TopPette 12-channel pipette is designed for microplate loading, PCR plate preparation, and ELISA workflows, indicating compatibility with standard 96-well microplates. The 12-channel format allows simultaneous pipetting into columns of 8 or 12 wells. However, the manufacturer recommends confirming tip compatibility and plate dimensions before ordering.

What are the sterilization requirements for the TopPette 12-channel pipette to prevent cross-contamination?

The lower half of the TopPette 12-channel pipette is autoclavable where indicated, allowing sterilization of the parts that contact liquid. The upper half should not be autoclaved. Users should follow the manufacturer's guidelines for proper sterilization procedures to maintain accuracy and prevent damage.

The TopPette 12-channel 10-100 µL pipette provides a manual, autoclavable multichannel platform for parallel liquid handling in microplate and PCR applications, with ISO 8655-2 calibration traceability. Users must verify error specifications at their selected test volume and note that only the lower half is autoclavable.

Positive

  • 12-channel parallel liquid handling: Enables simultaneous microplate loading, PCR plate preparation, and ELISA workflows, increasing throughput for repeated reagent transfers.
  • Autoclavable lower half for sterilization: The lower portion of the pipette can be autoclaved, allowing safe decontamination between biological samples without damaging the upper assembly.

Trade-offs

  • Calibration data must be reviewed per test volume: Systematic and random error values are listed for specific test volumes (100/50/10 µL); users must confirm accuracy at their target volume for method compliance.
  • Only lower half autoclavable: The upper assembly is not autoclavable, requiring careful partial disassembly and limiting full sterilization capability for applications demanding total decontamination.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).