Description
TopPette 12-channel 5-50 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The lower half of this pipette is autoclavable where indicated, requiring sterilization cycles that do not exceed manufacturer-recommended temperature and pressure limits. The instrument must be stored in a clean, dry environment within its calibrated temperature range to maintain systematic and random error specifications.
- Sterilization constraint: Only the lower half of the pipette is autoclavable, and sterilization must follow the indicated protocol to avoid damage to the upper assembly.
- Calibration constraint: The pipette requires periodic recalibration per ISO 8655-2 to maintain specified systematic and random error at test volumes of 50, 25, and 5 µL.
This procedure covers initial setup, volume adjustment, and tip attachment for the 12-channel pipette before routine liquid handling. Follow these steps to ensure accurate and repeatable microliter transfers in microplate or PCR workflows.
Required Equipment: Compatible pipette tips for 5-50 µL range, Calibration reference standard per ISO 8655-2
- Set volume
Rotate the volume adjustment knob to the desired volume within the 5-50 µL range using the 0.5 µL increment scale. - Attach tips
Press the pipette firmly onto compatible tips for the 5-50 µL range to ensure a stable seal across all 12 channels. - Verify calibration
Confirm that the pipette has been calibrated per ISO 8655-2 at the test volumes of 50, 25, and 5 µL before use. - Perform pre-wet cycle
Aspirate and dispense the selected volume at least three times to equilibrate the tip interior and improve repeatability.
How does the systematic error of the TopPette 12-channel 5-50 µL pipette vary across its volume range?
The systematic error is specified for three test volumes: 50 µL, 25 µL, and 5 µL. The exact values are retained in the technical table and should be reviewed for calibration planning. The pipette is calibrated per ISO 8655-2, and the error values are used to verify accuracy at each test volume.
Which pipette tips are compatible with the TopPette 12-channel 5-50 µL pipette for microplate loading?
The product description does not specify a particular tip brand or model. Users must confirm compatible tips before ordering, as tip fit is critical for repeatability in microplate and PCR plate workflows. The pipette is designed for a 5-50 µL volume range, so tips should be selected accordingly.
What are the sterilization requirements for the TopPette 12-channel 5-50 µL pipette?
Only the lower half of the pipette is autoclavable where indicated; the upper half is not autoclavable. Users should follow the manufacturer's guidelines for sterilization to avoid damage. The pipette is suitable for routine liquid handling where sterilization of the lower half is required.
The TopPette 12-channel 5-50 µL pipette offers a dedicated microliter liquid handling platform with a 0.5 µL increment and autoclavable lower half, suitable for microplate and PCR workflows where traceable ISO 8655-2 calibration data and repeatable parallel transfers are required.
Positive
- 12-channel high-throughput design: Enables efficient microplate loading, PCR plate preparation, and parallel reagent transfer, reducing handling time in multichannel workflows.
- Autoclavable lower half for sterility: The lower assembly can be autoclaved where indicated, allowing decontamination between uses in sensitive applications.
Trade-offs
- Restricted volume range: The 5-50 µL range and 0.5 µL increment limit the pipette to microliter-scale dispensing; not suitable for microliter volumes below 5 µL or above 50 µL.
- Tip and calibration dependency: Accurate performance requires compatible tips and routine calibration per ISO 8655-2; users must confirm tip fit and calibration schedule before deployment.