Single-Channel Pipette 0.5-10 μL ISO 8655-2 ATOMFAIR®

$214.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Single-channel 0.5-10 μL pipette with 0.01 μL increments, ISO 8655-2 calibration reference, and lower-half autoclavable design. Order now.

SKU: AF-EI-L-DPET-B010-SC00
Category: ,
Tags:
Brands:

Description

dPette Single-channel 0.5-10 µL Pipette

Product Type: Electronic pipette
Research-grade liquid handling platform

Product Overview

dPette Single-channel 0.5-10 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 0.5-10 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 0.5-10 µL working range, 0.01 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 0.5-10 µL with 0.01 µL increment.
  • Sterilization suitability: Lower half autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-DPETTE-0-5-10-µL
Product Family dPette
Channel count Single-channel
Volume range 0.5-10 µL
Increment 0.01 µL
Test volume(s) 10 / 5 / 1 µL
Systematic error At 10 µL: ±0.10 µL (±1.00%); at 5 µL: ±0.10 µL (±2.00%); at 1 µL: ±0.05 µL (±5.00%)
Random error At 10 µL: ±0.05 µL (±0.50%); at 5 µL: ±0.10 µL (±2.00%); at 1 µL: ±0.03 µL (±3.00%)
Sterilization suitability Lower half autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Electronic pipette technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The dPette single-channel pipette requires routine calibration per ISO 8655-2 and supports autoclaving of its lower half. Proper tip selection and volume verification are necessary to maintain specified systematic and random error limits.

  • Sterilization Constraint: Only the lower half of the pipette is autoclavable; do not autoclave the upper assembly.
  • Calibration Requirement: Calibrate the pipette using the three test volumes (10, 5, 1 µL) per ISO 8655-2 to maintain accuracy.
  • Tip Compatibility: Use only compatible pipette tips that fit the 0.5-10 µL range to avoid leakage and inaccuracy.

How does the dPette 0.5-10 µL pipette's accuracy and precision vary across its volume range, and what are the implications for low-volume assays?

The systematic error at 10 µL is ±1.00%, at 5 µL ±2.00%, and at 1 µL ±5.00%. Random error at 10 µL is ±0.50%, at 5 µL ±2.00%, and at 1 µL ±3.00%. This significant degradation in both accuracy and precision at the lowest end of the range means that for applications such as PCR setup or serial dilutions requiring volumes near 1 µL, the pipette may introduce higher relative error, requiring careful method validation or use of a lower-volume pipette.

What are the critical compatibility and sterilization constraints for the dPette 0.5-10 µL pipette in a BSL-2 or PCR laboratory?

The pipette's lower half is autoclavable, but the upper half is not, so full sterilization of the entire pipette is not possible. Users must confirm compatible tips before ordering, as the 0.5-10 µL range requires specific tip types. The pipette also requires calibration per ISO 8655-2, which may need to be repeated after autoclaving to maintain specification.

What calibration and maintenance procedures are required for the dPette 0.5-10 µL pipette to ensure reliable performance?

The pipette is calibrated according to ISO 8655-2, with test volumes at 10, 5, and 1 µL. For routine maintenance, the lower half can be autoclaved, but the user should confirm compatible tips, calibration requirements, and sterilization needs before ordering. Regular calibration verification is recommended, especially after autoclaving or when switching between different liquids, to ensure systematic and random errors remain within specifications.

The dPette Single-channel 0.5-10 µL Pipette offers a fine 0.01 µL increment and partial autoclavability for contamination control, but accuracy degrades at the lower end of the range (1 µL ±5% systematic error) and full sterilization is limited to the lower half.

Positive

  • Lower half autoclavable for contamination control: The lower half of the pipette can be autoclaved, enabling sterilization of the tip contact area to reduce cross-contamination risk in aseptic workflows.
  • Fine 0.01 µL increment for precise volume selection: The 0.01 µL increment allows fine adjustment of dispensed volumes, supporting accurate microvolumetric transfers within the 0.5-10 µL range.

Trade-offs

  • Large systematic error at 1 µL test volume: At 1 µL, the systematic error is ±5.00%, which may limit accuracy for low-volume applications requiring high precision.
  • Only lower half autoclavable, not full unit: The upper half of the pipette is not autoclavable, requiring alternative sterilization methods for the entire device or careful handling to maintain sterility.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).