Silver Disk Working Electrode 2–6 mm, <4 mm ATOMFAIR®

Price range: $106.00 through $120.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade silver disk working electrode with 2–6 mm diameters and <4 mm head thickness for electrochemistry, SEM, and AFM correlation. Order now.

Multifunctional Combination Silver Disk Working Electrode Series | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Multifunctional Combination Silver Disk Working Electrode features a high-performance silver disk as the active sensing surface, offering excellent conductivity, favorable halide interactions, and reliable performance for potentiometric and voltammetric applications. The electrode incorporates an embedded disk design with diameters available including 2mm, 3mm, 4mm, 5mm, and 6mm, accommodating diverse experimental scales from micro-electrode sensing to macro-electrode bulk electrolysis. The electrode head thickness is less than 4mm, enabling use as a standard working electrode for conventional electrochemical measurements as well as direct integration with scanning electron microscopy (SEM) or atomic force microscopy (AFM) systems. This dual-purpose design bridges bulk electrochemistry and high-resolution surface characterization, allowing researchers to correlate electrochemical performance with structural and topographical features on the identical electrode surface.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry Modular detachable configuration
Electrode Head Thickness Less than 4mm
Compatible Techniques Conventional electrochemistry, SEM, AFM
2. Electrode Material Portfolio Parameters
Material Silver
Diameter Options 2mm, 3mm, 4mm, 5mm, 6mm

Key Features & Advantages

  • Correlative Electrochemical-Microscopic Analysis: Enables direct structural and topographical correlation with electrochemical data from the identical electrode location without sample transfer.

  • Excellent Electrical Conductivity: Constructed from premium-grade silver with superior conductive properties, ensuring minimal ohmic drop, low electrical resistance, and highly reproducible electrochemical responses across all experiments.

  • Superior Electrochemical Performance: Exhibits excellent electron transfer kinetics with unique electrochemical characteristics, making it ideal for mercury film electrode preparation, halide sensing, and various redox systems within its operational potential window.

  • Versatile Diameter Selection: Available in 5 different sizes from 2mm to 6mm, accommodating various experimental requirements from micro-electrolysis to bulk solution analysis.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The electrode surface is highly sensitive to contamination and must be stored in a sealed container or handled exclusively within an anhydrous inert atmosphere to prevent phase degradation. The embedded silver disk design with head thickness under 4 mm enables direct integration with SEM or AFM systems without sample transfer.

  • Surface Contamination Sensitivity: Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.

Initialize the electrode by verifying surface cleanliness and mounting it securely in the electrochemical cell. After use, clean the silver disk surface and store the electrode in a sealed protective container under inert atmosphere.

Required Equipment: Anhydrous inert environment (glovebox or gas line), Protective sealed container with shock absorption

  1. Inspect Electrode Surface
    Inspect the silver disk surface for any visible contamination or oxidation before use.
  2. Mount Electrode in Cell
    Mount the electrode securely into the electrochemical cell, ensuring the head thickness does not exceed 4 mm for proper fit.
  3. Perform Electrochemical Measurement
    Perform the desired potentiometric or voltammetric measurement within the operational potential window of silver.
  4. Clean Electrode Surface
    Clean the silver disk surface immediately after use to remove any residual electrolyte or reaction products.
  5. Store Electrode Under Inert Atmosphere
    Store the electrode in a sealed protective container under anhydrous inert atmosphere to prevent surface degradation.

How does the choice of electrode diameter affect the trade-off between sensitivity for micro-electrode sensing and current capacity for bulk electrolysis?

The 2 mm diameter provides enhanced sensitivity for micro-electrode applications due to reduced capacitive currents and smaller geometric area, while the 6 mm diameter offers higher total current for macro-electrode bulk electrolysis. The available diameters from 2 mm to 6 mm span micro-sensing to bulk analysis scales, but only the electrode head thickness (less than 4 mm) remains constant to maintain SEM/AFM compatibility across all sizes.

Can this silver disk electrode be integrated directly into scanning electron microscopy or atomic force microscopy setups without additional sample transfer?

Yes, the electrode head thickness of less than 4 mm allows direct integration with SEM or AFM systems, enabling correlative electrochemical-microscopic analysis on the identical electrode surface. This design eliminates the need for sample transfer between electrochemical and microscopy experiments, preserving the spatial relationship between electrochemical activity and surface structure.

What handling and storage conditions are required to maintain the silver electrode surface integrity before use?

This electrode is highly sensitive to surface contamination. Containers must be kept tightly sealed or the electrode handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.

This silver disk working electrode offers diameters from 2 to 6 mm and a thin head (<4 mm) enabling direct SEM or AFM integration without sample transfer for correlative electrochemical-microscopic analysis, but requires strict contamination control during storage and handling.

Positive

  • Correlative electrochemistry and microscopy capability: The embedded disk design with head thickness less than 4 mm allows direct integration with SEM or AFM systems without sample transfer, enabling structural and topographical correlation with electrochemical data from the identical electrode surface.
  • Multiple diameter options for experimental flexibility: Available in five diameters from 2 mm to 6 mm, accommodating experimental scales from micro-electrode sensing to macro-electrode bulk electrolysis.

Trade-offs

  • High surface contamination sensitivity: The silver disk working electrode is highly sensitive to surface contamination; containers must remain tightly sealed or handling performed exclusively within an anhydrous inert environment to prevent degradation before electrochemical validation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Electrode Diameter

2 mm, 3 mm, 4 mm, 5 mm, 6 mm