Silicon PV Cell Experiment Device SPCE-639 ATOMFAIR®

$8,800.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

SPCE-639 research-grade silicon photovoltaic cell device measures I-V curves, efficiency, fill factor and resistance with adjustable white light. Order now.

Brands:

ATOMFAIR-SPCE-639 SILICON PHOTOVOLTAIC CELL CHARACTERISTICS EXPERIMENT DEVICE

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR-SPCE-639 is a high-quality Silicon Photovoltaic Cell Experiment device designed for the research and analysis of silicon photovoltaic cell characteristics. Belonging to the optoelectronics and laser category, this instrument features an adjustable light source illuminance meter configuration that simulates different light intensity conditions for comprehensive cell characterization. The main unit is equipped with real-time voltage current display functions for immediate data monitoring during experiments. Users can independently design and connect optical paths to carry out customized experiments, precisely measuring critical parameters including optical power, open-circuit voltage, and short-circuit current. The device facilitates conversion efficiency fill factor measurement and internal resistance determination, providing comprehensive insights into cell performance. The included guide rail, sliding seat, and dry plate holder support stable and flexible experimental setups. With its precise configuration and user-friendly design, this device meets international standards and is an essential tool for exploring the performance and potential of silicon photovoltaic technology.

Technical Specifications

PARAMETER DETAILS
Product Name ATOMFAIR-SPCE-639 Silicon Photovoltaic Cell Characteristics Experiment Device
Product Code SPCE-639
Product Type Optoelectronics and Laser
Main Unit Equipped with Current and Voltage Display Functions for Real-Time Data Monitoring
Light Source Adjustable-Brightness White Light Source to Simulate Different Light Intensity Conditions
Test Object High-Performance Silicon Photovoltaic Cell Panel
Illuminance Meter Portable Design for Convenient Measurement of Light Intensity
Other Accessories Guide Rail, Sliding Seat, Dry Plate Holder for Stable and Flexible Experimental Setup
Custom Configurations Other configurations and custom specifications are available upon request. Please contact us via email for specialized inquiries.

Key Features & Advantages

  • Comprehensive Photovoltaic Parameter Measurement: Precisely measure critical parameters including optical power, open-circuit voltage, short-circuit current, conversion efficiency, fill factor, and internal resistance, providing complete performance characterization of silicon photovoltaic cells.
  • Adjustable Light Source for Multi-Condition Testing: The adjustable-brightness white light source simulates different light intensity conditions, enabling systematic investigation of illumination-dependent photovoltaic behavior and performance regularity.
  • Independent Optical Path Design Capability: Users can independently design and connect optical paths to carry out customized experiments according to specific research needs, providing pedagogical and research flexibility beyond fixed-configuration systems.
  • Real-Time Voltage and Current Display with I-V Curve Plotting: The main unit displays real-time data while facilitating the plotting of volt-ampere characteristic curves for intuitive visualization of cell performance regularity and operational behavior.

APPLICATION SCOPE: Research and analysis of silicon photovoltaic cell characteristics in optoelectronics and laser laboratories. Educational experiments for understanding photovoltaic conversion principles and solar cell performance parameters. Material science investigations of light-to-electricity conversion efficiency. Quality assessment and performance benchmarking of silicon photovoltaic cells. Customized optical path experiments for specialized photovoltaic research applications.
PACKAGING: Each SPCE-639 experiment device is supplied as a complete system including the main unit with current/voltage display, adjustable-brightness white light source, high-performance silicon photovoltaic cell panel, portable illuminance meter, guide rail, sliding seat, and dry plate holder. All components are securely packed to prevent damage during transit.
IMPORTANT NOTICE: The above configurations and parameters are for reference only. The actual product shall be subject to the packing list provided with the shipment. Minor changes may occur without prior notice. Handle the silicon photovoltaic cell panel with care to avoid surface damage or contamination that may affect measurement accuracy. Calibrate the illuminance meter before initial use. For detailed assembly, calibration, and operational instructions, consult the user manual prior to first use. If you have specific customization requirements, please contact us at inquiry@atomfair.com.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The silicon photovoltaic cell panel must be handled carefully to avoid surface damage or contamination that could affect measurement accuracy. The portable illuminance meter must be calibrated before initial use to ensure accurate light intensity measurements.

  • Photovoltaic Cell Panel Handling: Handle the silicon photovoltaic cell panel with care to avoid surface damage or contamination that may affect measurement accuracy.
  • Illuminance Meter Calibration: Calibrate the illuminance meter before initial use to ensure accurate light intensity measurements.

What photovoltaic parameters can be measured with the ATOMFAIR-SPCE-639 silicon photovoltaic cell experiment device?

The SPCE-639 precisely measures critical photovoltaic parameters including optical power, open-circuit voltage, short-circuit current, conversion efficiency, fill factor, and internal resistance. These measurements are supported by the real-time voltage and current display, adjustable white light source, and the capability to plot volt-ampere characteristic curves for comprehensive performance characterization.

Can the SPCE-639 be integrated with custom optical paths for specialized photovoltaic research?

Yes, the device allows users to independently design and connect optical paths for customized experiments beyond fixed-configuration systems. The included guide rail, sliding seat, and dry plate holder provide a stable and flexible platform for mounting optical components, enabling tailored experimental configurations for specialized photovoltaic research applications.

What handling and calibration precautions are required for the silicon photovoltaic cell panel and illuminance meter?

Handle the silicon photovoltaic cell panel with care to avoid surface damage or contamination that may affect measurement accuracy. Calibrate the portable illuminance meter before initial use to ensure reliable light intensity readings. For detailed assembly, calibration, and operational instructions, consult the user manual prior to first use.

The ATOMFAIR-SPCE-639 is a research-grade silicon photovoltaic cell characterization platform that integrates an adjustable-brightness white light source, portable illuminance meter, and real-time current/voltage display for multi-parameter assessment including conversion efficiency, fill factor, and internal resistance. Its open optical rail design supports custom optical path configurations, making it suitable for both educational and specialized photovoltaic research applications.

Positive

  • Comprehensive photovoltaic parameter measurement: Measures optical power, open-circuit voltage, short-circuit current, conversion efficiency, fill factor, and internal resistance, enabling complete performance characterization of silicon photovoltaic cells.
  • Adjustable light source for multi-condition testing: The adjustable-brightness white light source simulates varying light intensities, allowing systematic investigation of illumination-dependent photovoltaic behavior and performance trends.

Trade-offs

  • Requires careful cell handling: The silicon photovoltaic cell panel must be handled with care to avoid surface damage or contamination, which could compromise measurement accuracy.
  • Calibration required before use: The illuminance meter must be calibrated prior to initial use, and users must consult the manual for proper assembly and calibration procedures to ensure reliable measurements.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).